Pump operation monitoring applying frequency converter

Variable speed driven (VSD) pumps are nowadays widely used in industry applications. Variable speed pumping improves operational flexibility of the pump drive compared with throttle control. In many cases this results in energy cost savings. Nowadays, the performance of frequency converters allows their use as an intelligent monitoring device for the pump drive. This provides new possibilities for the maintenance and operation personnel. In this article, some functions provided by the frequency converter for pump condition and operation monitoring are explained. The applicability of a frequency converter for monitoring purposes is also discussed.

[1]  Paula Fonseca,et al.  Characterisation of the Electricity Use in European Union and the Savings Potential in 2010 , 1997 .

[2]  Michael Volk Pump Characteristics and Applications , 1996 .

[3]  Aimee McKane,et al.  Variable speed pumping: A guide to successful applications , 2004 .

[4]  V. Kokko CONDITION MONITORING OF SQUIRREL-CAGE MOTORS BY AXIAL MAGNETIC FLUX MEASUREMENTS , 2003 .

[5]  P.N. Enjeti,et al.  A Real Time Method to Estimate Electrolytic Capacitor Condition in PWM Adjustable Speed Drives and Uninterruptible Power Supplies , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[6]  Tuomo Lindh,et al.  On the Condition Monitoring of Induction machines , 2003 .

[7]  E.L. Owen,et al.  Assessment of the Reliability of Motors in Utility Applications - Updated , 1986, IEEE Transactions on Energy Conversion.

[8]  Markku Niemela,et al.  Ethernet-based broadband power line communication between motor and inverter , 2008 .

[9]  Paresh Girdhar Practical Machinery Vibration Analysis and Predictive Maintenance , 2004 .

[10]  Juha Viholainen,et al.  Testing the accuracy of pump flow calculation without metering , 2005 .

[11]  O Gol,et al.  Condition Monitoring of Electrical Machines , 1986 .

[12]  T.G. Habetler,et al.  Condition Monitoring of Electrolytic Capacitor in Power Electronic Circuits using Adaptive Filter Modeling , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[13]  T. Lindh,et al.  Utilization possibilities of frequency converter in electric motor diagnostics , 2006, International Symposium on Power Electronics, Electrical Drives, Automation and Motion, 2006. SPEEDAM 2006..

[14]  PF Albrecht,et al.  Assessment of the Reliability of Motors in Utility Applications , 1987, IEEE Transactions on Energy Conversion.

[15]  T. Lindh,et al.  Estimation of the data transfer requirements of vibration and temperature measurements in induction motor condition monitoring , 2005, 2005 European Conference on Power Electronics and Applications.

[16]  David Mba,et al.  Development of Acoustic Emission Technology for Condition Monitoring andDiagnosis of Rotating Machines; Bearings, Pumps, Gearboxes, Engines and RotatingStructures. , 2006 .

[17]  Gunnar Hovstadius Getting it Right, Applying a Systems Approach to Variable Speed Pumping , 2005 .

[18]  S I Abdul Raouf,et al.  Predictive Maintenance of Pumps Using Condition Monitoring , 2005 .