CdTe stacked detectors for gamma-ray detection

We describe a stacked detector made of thin cadmium telluride (CdTe) diode detectors. By using a thin CdTe device, we can overcome the charge loss problem due to the small mobility and short lifetime of holes in CdTe or cadmium zinc telluride (CdZnTe) detectors. However, a CdTe detector with a thickness of more than 5 mm is needed for adequate detection efficiency for gamma-rays of several hundred keV. Good energy resolution and good peak detection efficiency are difficult to obtain using such a thick CdTe detector. The stacked detector enabled us to realize a detector with both high-energy resolution and good efficiencies for gamma rays up to several hundred keV. In order to verify this concept, we constructed a prototype made of ten layers of a 0.5-mm-thick CdTe diode detectors with a surface area of 21.5 mm/spl times/21.5 mm. With this, we have achieved 5.3-keV and 7.9-keV energy resolution [full width at half maximum (FWHM)] at 356 keV and 662 keV, respectively, at the temperature of -20/spl deg/C.

[1]  Goro Sato,et al.  High resolution CdTe detector and applications to imaging devices , 2000 .

[2]  Response calculation of a stacked CdZnTe detector for 16N γ-ray measurement , 2001 .

[3]  K. Hecht Zum Mechanismus des lichtelektrischen Primärstromes in isolierenden Kristallen , 1932 .

[4]  Kazuyuki Hirose,et al.  High-resolution Schottky CdTe diode for hard X-ray and gamma-ray astronomy , 1999 .

[5]  H. B. Barber,et al.  Charge transport in arrays of semiconductor gamma-ray detectors. , 1995, Physical review letters.

[6]  Kunishiro Mori,et al.  Performance of a new Schottky CdTe detector for hard X-ray spectroscopy , 1997 .

[7]  Tadayuki Takahashi,et al.  High resolution Schottky CdTe diode detector , 2001 .

[8]  Tadayuki Takahashi,et al.  Characterization of CdTe/CdZnTe detectors , 2001 .

[9]  J. F. Butler,et al.  Novel electrode design for single-carrier charge collection in semiconductor nuclear radiation detectors , 1997 .

[10]  Israel Mardor,et al.  CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems , 1999 .

[11]  Tadayui Takahashi,et al.  Recent progress in CdTe and CdZnTe detectors , 2001, astro-ph/0107398.

[12]  H. Takamura,et al.  THERMAL TREATMENT OF CDTE SURFACES FOR RADIATION DETECTORS , 1996 .

[13]  P. Luke Single-polarity charge sensing in ionization detectors using coplanar electrodes , 1994 .

[14]  W. Akutagawa,et al.  Analysis of CdTe Probes , 1972 .

[15]  C. Canali,et al.  Gamma−ray spectroscopy with single−carrier collection in high−resistivity semiconductors , 1975 .