Experimental analysis of the R744 vapour compression rack equipped with the multi-ejector expansion work recovery module

Abstract A test facility for the experimental investigation of the R744 vapour compression rack equipped with a multi-ejector expansion work recovery module was designed and manufactured. A comparison of the R744 multi-ejector refrigeration system with the R744 parallel compression system at the same test facility was carried out based on the energy performance characteristics of refrigeration capacity, power consumption, COP, and exergy efficiency. Apart from the system performance comparison, the influence of the pressure level in the flash tank on the system performance for the two alternatives was analysed. The experimental results indicate COP and exergy efficiency improvements of the multi-ejector refrigeration system up to 7% and 13.7%, respectively. The highest values of COP and exergy efficiency were obtained by a multi-ejector refrigeration system with the tank pressure lift close to the maximum value possible to operate the multi-ejector expansion module. The values of the effective compressor efficiencies were significantly different, depending on the operation module (cooling load and heat rejection conditions).

[1]  Jostein Pettersen,et al.  Fundamental process and system design issues in CO2 vapor compression systems , 2004 .

[2]  Paul R. Wyrwoll,et al.  Section 1.1 The Montreal Protocol on Substances that Deplete the Ozone Layer , 2012, Concise Handbook of Fluorocarbon Gases.

[3]  Waclaw Kus,et al.  CFD-based shape optimisation of a CO2 two-phase ejector mixing section , 2016 .

[4]  W. Wagner,et al.  A New Equation of State for Carbon Dioxide Covering the Fluid Region from the Triple‐Point Temperature to 1100 K at Pressures up to 800 MPa , 1996 .

[5]  A. A. Kornhauser,et al.  Improvements to the ejector expansion refrigeration cycle , 1996, IECEC 96. Proceedings of the 31st Intersociety Energy Conversion Engineering Conference.

[6]  Jahar Sarkar,et al.  Performance optimization of transcritical CO2 cycle with parallel compression economization , 2010 .

[7]  K. Lambers Isentropic and Volumetric Efficiencies for Compressors with Economizer Port , 2008 .

[8]  Shengming Liao,et al.  A correlation of optimal heat rejection pressures in transcritical carbon dioxide cycles , 2000 .

[9]  Sven Försterling,et al.  Multi-ejector concept for R-744 supermarket refrigeration , 2014 .

[10]  Neal Lawrence,et al.  Theoretical and practical comparison of two-phase ejector refrigeration cycles including First and Second Law analysis , 2013 .

[11]  Alan A. Kornhauser,et al.  The Use of an Ejector as a Refrigerant Expander , 1990 .

[12]  Predrag Stojan Hrnjak,et al.  Experimental validation of a prototype ejector designed to reduce throttling losses encountered in transcritical R744 system operation , 2008 .

[13]  Jahar Sarkar,et al.  Performance characteristics of natural-refrigerants- based ejector expansion refrigeration cycles , 2009 .

[14]  E. Filho,et al.  Comparison of a R744 cascade refrigeration system with R404A and R22 conventional systems for supermarkets , 2012 .

[15]  Petter Nekså,et al.  Commercial refrigeration system using CO2 as the refrigerant , 2004 .

[16]  Stefan Elbel,et al.  Historical and present developments of ejector refrigeration systems with emphasis on transcritical carbon dioxide air-conditioning applications , 2011 .

[17]  Barry N. Taylor,et al.  Guidelines for Evaluating and Expressing the Uncertainty of Nist Measurement Results , 2017 .

[18]  Giovanni Ferrara,et al.  Experimental analysis of R744 parallel compression cycle , 2014 .

[19]  Chi-Chuan Wang,et al.  An overview of the effect of lubricant on the heat transfer performance on conventional refrigerants and natural refrigerant R-744 , 2012 .

[20]  Robert J. Moffat,et al.  Describing the Uncertainties in Experimental Results , 1988 .

[21]  Trond Andresen,et al.  Experimental and numerical investigation of the influence of the two-phase ejector geometry on the performance of the R744 heat pump , 2012 .

[22]  Brian A. Fricke,et al.  Comparative analysis of various CO2 configurations in supermarket refrigeration systems , 2014 .

[23]  Armin Hafner,et al.  Application range of the HEM approach for CO2 expansion inside two-phase ejectors for supermarket refrigeration systems , 2015 .

[24]  Mehmet Kanoglu,et al.  Exergy analysis of vapor compression refrigeration systems , 2002 .

[25]  Savvas A. Tassou,et al.  Thermodynamic analysis of transcritical CO2 booster refrigeration systems in supermarket , 2011 .

[26]  Pradeep Bansal,et al.  A review – Status of CO2 as a low temperature refrigerant: Fundamentals and R&D opportunities , 2012 .

[27]  Somchai Wongwises,et al.  Effect of throat diameters of the ejector on the performance of the refrigeration cycle using a two-phase ejector as an expansion device , 2007 .

[28]  Pradeep Bansal,et al.  Thermodynamic analysis of an R744-R717 cascade refrigeration system , 2008 .

[29]  Pei-Xue Jiang,et al.  Particular characteristics of transcritical CO2 refrigeration cycle with an ejector , 2007 .

[30]  M. McLinden,et al.  NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP, Version 9.1 | NIST , 2013 .

[31]  S. Sawalha,et al.  Field measurements of supermarket refrigeration systems. Part I: Analysis of CO2 trans-critical refrigeration systems , 2015 .

[32]  Armin Hafner,et al.  A computational model of a transcritical R744 ejector based on a homogeneous real fluid approach , 2013 .

[33]  Samer Sawalha,et al.  Theoretical evaluation of trans-critical CO2 systems in supermarket refrigeration. Part II: System modifications and comparisons of different solutions , 2008 .

[34]  Andy Pearson,et al.  ICR0021 CARBON DIOXIDE - NEW USES FOR AN OLD REFRIGERANT , 2005 .

[35]  Eckhard A. Groll,et al.  Transcritical CO2 refrigeration cycle with ejector-expansion device , 2005 .

[36]  Farid Nasir Ani,et al.  A review on two-phase ejector as an expansion device in vapor compression refrigeration cycle , 2012 .

[37]  Team Coolpack CoolPack – Simulation tools for refrigeration systems , 1999 .

[38]  Hui Li,et al.  EXERGY ANALYSIS OF A DUAL-MODE REFRIGERATION SYSTEM FOR ICE STORAGE AIR CONDITIONING , 2005 .

[39]  J. U. Ahamed,et al.  A review on exergy analysis of vapor compression refrigeration system , 2011 .

[40]  Armin Hafner,et al.  Development and performance mapping of a multi-ejector expansion work recovery pack for R744 vapour compression units. , 2015 .