QUIC transport and dispersion modelling of two releases from the Joint Urban 2003 field experiment

An in-depth comparison of plume calculations from the Quick Urban and Industrial Complex (QUIC) dispersion model to street- and roof-level concentration measurements for a daytime and night time release taken during the Joint Urban 2003 field experiment held in downtown Oklahoma City is presented. A number of improvements to the empirical-diagnostic wind solver to better account for high-rise buildings and dense urban areas will be discussed. Traditional plume statistical performance measures reveal that the code is performing as well as computational fluid dynamics models and meets the criteria proposed by Hanna and Chang (2012) for urban dispersion models. Statistics for the day and night release are fairly similar, and model performance drops slightly after the release is turned off in the flushing phase. Scatterplots indicate that rooftop measurements were generally well predicted, although the percentage of outliers (false negatives, large over predictions) was greater as compared to street-level measurements. Using all tracer data within a kilometre of the release, including rooftop samplers, from 39 to 46% of the model-computed concentrations were within a factor of two of the observations when broken up into four cases stratified by day or night and release on or off.

[1]  Evaluation of a Fast-Running Urban Dispersion Modeling System Using Joint Urban 2003 Field Data , 2007 .

[2]  David K. Heist,et al.  Sand Flux Simulations at a Small Scale over a Heterogeneous Mesquite Area of the Northern Chihuahuan Desert , 2007 .

[3]  Hansheng Pan,et al.  Lateral channeling within rectangular arrays of cubical obstacles , 2010 .

[4]  Eric R. Pardyjak,et al.  Evaluation of a fast response pressure solver for flow around an isolated cube , 2010 .

[5]  Rebecca Vernot,et al.  Comparisons of JU2003 observations with four diagnostic urban wind flow and Lagrangian particle dispersion models , 2011 .

[6]  Steven R. Hanna,et al.  Acceptance criteria for urban dispersion model evaluation , 2012, Meteorology and Atmospheric Physics.

[7]  J. Heagy,et al.  User-Oriented Two-Dimensional Measure of Effectiveness for the Evaluation of Transport and Dispersion Models , 2004 .

[8]  Michael J. Brown,et al.  Urban dispersion : challenges for fast response modeling , 2004 .

[9]  J. Heagy,et al.  Comparisons of Transport and Dispersion Model Predictions of the Joint Urban 2003 Field Experiment , 2008 .

[10]  J. Lundquist,et al.  Consequences of Urban Stability Conditions for Computational Fluid Dynamics Simulations of Urban Dispersion , 2007 .

[11]  Fan Wang,et al.  Using a CFD approach for the study of street-level winds in a built-up area , 2005 .

[12]  C. Sherman A Mass-Consistent Model for Wind Fields over Complex Terrain. , 1978 .

[13]  Stephen V Musolino,et al.  EMERGENCY RESPONSE GUIDANCE FOR THE FIRST 48 HOURS AFTER THE OUTDOOR DETONATION OF AN EXPLOSIVE RADIOLOGICAL DISPERSAL DEVICE , 2006, Health physics.

[14]  Jay P. Boris,et al.  Large Scale Urban Contaminant Transport Simulations With Miles , 2007 .

[15]  Balwinder Singh,et al.  Evaluation of the QUIC-URB fast response urban wind model for a cubical building array and wide building street canyon , 2008 .

[16]  John D. Spengler,et al.  Using advanced dispersion models and mobile monitoring to characterize spatial patterns of ultrafine particles in an urban area , 2011 .

[17]  Inanc Senocak,et al.  A CFD-based wind solver for an urban fast response transport and dispersion model , 2011 .

[18]  M. J. Brown,et al.  Improved upwind cavity parameterization for a fast response urban wind model , 2004 .

[19]  Robert N. Meroney,et al.  Concentration and flow distributions in the vicinity of U-shaped buildings: Wind-tunnel and computational data , 1997 .

[20]  Vlad Isakov,et al.  The effects of roadside structures on the transport and dispersion of ultrafine particles from highways , 2007 .

[21]  N. Dinar,et al.  A lagrangian dispersion model for calculating concentration distribution within a built-up domain , 1996 .

[22]  John Paul Iselin,et al.  A comparison of contaminant plume statistics from a Gaussian puff and urban CFD model for two large cities , 2005 .

[23]  Brent C. Hedquist,et al.  Flow, turbulence, and pollutant dispersion in urban atmospheresa) , 2010 .

[24]  R. Britter,et al.  FLOW AND DISPERSION IN URBAN AREAS , 2003 .

[25]  Akshay Gowardhan,et al.  An inter-comparison of three urban wind models using Oklahoma City Joint Urban 2003 wind field measurements , 2011 .

[26]  Nicolas Moussiopoulos,et al.  The microscale model MIMO: development and assessment , 2000 .