Modeling of carbon fiber couch attenuation properties with a commercial treatment planning system.

The purpose of this work is to evaluate the modeling of carbon fiber couch attenuation properties with a commercial treatment planning system (TPS, Pinnacle3, v8.0d). A carbon fiber couch (Brain-Lab) was incorporated into the TPS by automatic contouring of all transverse CT slices. The couch shape and dimensions were set according to the vendor specifications. The couch composition was realized by assigning appropriate densities to the delineated contours. The couch modeling by the TPS was validated by absolute dosimetric measurements. A phantom consisting of several solid water slabs was CT scanned, the CT data set was imported into the TPS, and the carbon fiber couch was auto-contoured. Open (unblocked) field plans for different gantry angles and field sizes were generated. The doses to a point at 3 cm depth, placed at the linac isocenter, were computed. The phantom was irradiated according to the dose calculation setup and doses were measured with an ion chamber. In addition, percent depth dose (PDD) curves were computed as well as measured with radiographic film. The calculated and measured doses, transmissions, and PDDs were cross-compared. Doses for several posterior fields (0 degree, 30 degrees, 50 degrees, 75 degrees, 83 degrees) were calculated for 6 and 18 MV photon beams. For model validation a nominal field size of 10 x 10 cm2 was chosen and 100 MU were delivered for each portal. The largest difference between computed and measured doses for those posterior fields was within 1.7%. A comparison between computed and measured transmissions for the aforementioned fields was performed and the results were found to agree within 1.1%. The differences between computed and measured doses for different field sizes, ranging from 5 x 5 cm2 to 25 x 25 cm2 in 5 cm increments, were within 2%. Measured and computed PDD curves with and without the couch agree from the surface up to 30 cm depth. The PDDs indicate a surface dose increase resulting from the carbon fiber couch field modification. The carbon fiber couch attenuation for individual posterior oblique fields (75 degrees) can be in excess of 8% depending on the beam energy and field size. When the couch is contoured in Pinnacle3 its attenuation properties are modeled to within 1.7% with respect to measurements. These results demonstrate that appropriate contouring together with relevant density information for the contours is sufficient for adequate modeling of carbon fiber supporting devices by modern commercial treatment planning systems.

[1]  B. Schaeken,et al.  The effect of carbon fibre inserts on the build-up and attenuation of high energy photon beams. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  S. Burch,et al.  A new approach to film dosimetry for high energy photon beams: lateral scatter filtering. , 1997, Medical physics.

[3]  K. Langmack,et al.  An investigation into the use of carbon fibre for megavoltage radiotherapy applications. , 1998, Physics in medicine and biology.

[4]  G. Starkschall,et al.  American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: quality assurance for clinical radiotherapy treatment planning. , 1998, Medical physics.

[5]  D. Rogers,et al.  AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. , 1999, Medical physics.

[6]  C. Enke,et al.  Immobilization devices for intensity-modulated radiation therapy (IMRT). , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[7]  Two-dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device. , 2003, Medical physics.

[8]  Jennifer Diffey,et al.  The effect of gantry angle on megavoltage photon beam attenuation by a carbon fiber couch insert. , 2005, Medical physics.

[9]  David Wilkins,et al.  Investigating treatment dose error due to beam attenuation by a carbon fiber tabletop , 2006, Journal of applied clinical medical physics.

[10]  M. Kudrimoti,et al.  Spatially Fractionated GRID Radiation Treatment of Advanced Neck Disease Associated with Head and Neck Cancer , 2006 .

[11]  A. Meigooni,et al.  Dosimetric evaluation of parallel opposed spatially fractionated radiation therapy of deep-seated bulky tumors. , 2007, Medical physics.

[12]  Armand Djouguela,et al.  The Effect of a Carbon-Fiber Couch on the Depth-Dose Curves and Transmission Properties for Megavoltage Photon Beams , 2007, Strahlentherapie und Onkologie.

[13]  Khalil Sultanem,et al.  Comparison of repositioning accuracy of two commercially available immobilization systems for treatment of head-and-neck tumors using simulation computed tomography imaging. , 2008, International journal of radiation oncology, biology, physics.

[14]  Geoffrey Hugo,et al.  Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy. , 2007, International journal of radiation oncology, biology, physics.