Image quality, scatter, and dose in compact CBCT systems with flat and curved detectors

Purpose: A number of cone-beam CT (CBCT) applications demand increasingly compact system designs for smaller footprint and improved portability. Such compact geometries can be achieved via reduction of air gap and integration of novel, curved detectors; however, the increased x-ray scatter in presents a major challenge to soft-tissue image quality in such compact arrangements. This work investigates pre-patient modulation (bowtie filters) and antiscatter grids to mitigate such effects for compact geometries with curved detectors. Methods: The effects of bowtie filters on dose and x-ray scatter were investigated in a compact geometry (180 mm air gap), for three detector curvatures: Flat, Focused at source, and Compact focused at isocenter. Experiments used bowtie filters of varying curvature combined with antiscatter grids (GR: 8:1, 80 lpmm). Scatter was estimated via GPU-accelerated Monte Carlo simulation in an anthropomorphic head phantom. Primary fluence was estimated with a polychromatic Siddon projector. Realistic Poisson noise (total dose: 20 mGy) was added to the total signal. Scatter magnitude and distribution were evaluated in projection data, and CT image quality was assessed in PWLS reconstructions. Results were validated in physical experiments on an x-ray test-bench for CBCT. Results: Moderate bowties combined with grids reduced average scatter magnitude and SPR, reduced cupping from 90 to 5 HU, and yielded net benefit to CNR despite attenuation of primary fluence. Dose to sensitive organs (eye lens) was reduced by 27%. More aggressive bowties showed further potential for dose reduction (35%) but increased peripheral SPR and increased non-uniformity and artifacts at the periphery of the image. Curved detector geometry exhibited slightly improved uniformity but a slight reduction in CNR compared to conventional flat detector geometry. Conclusion: Highly portable, soft-tissue imaging, CBCT systems with very compact geometry and curved detectors appear feasible, despite elevated x-ray scatter, through combination of moderate pre-patient collimation and antiscatter grids.

[1]  G Kleinszig,et al.  Antiscatter grids in mobile C-arm cone-beam CT: effect on image quality and dose. , 2011, Medical physics.

[2]  Jan Sijbers,et al.  Reduction of ring artefacts in high resolution micro-CT reconstructions. , 2004, Physics in medicine and biology.

[3]  J. Boone,et al.  Dedicated breast CT: radiation dose and image quality evaluation. , 2001, Radiology.

[4]  J Yorkston,et al.  High-fidelity artifact correction for cone-beam CT imaging of the brain , 2015, Physics in medicine and biology.

[5]  J H Siewerdsen,et al.  Modeling and design of a cone-beam CT head scanner using task-based imaging performance optimization , 2016, Physics in medicine and biology.

[6]  Marc Kachelrieß,et al.  Interesting detector shapes for third generation CT scanners. , 2013, Medical physics.

[7]  R. A. Street,et al.  Flexible X-Ray Detector Array Fabricated With Oxide Thin-Film Transistors , 2012, IEEE Electron Device Letters.

[8]  D R Dance,et al.  X-ray transmission formula for antiscatter grids. , 1983, Physics in medicine and biology.

[9]  Wojciech Zbijewski,et al.  Evaluation of detector readout gain mode and bowtie filters for cone-beam CT imaging of the head. , 2016, Physics in medicine and biology.

[10]  D. Yang,et al.  A dedicated cone-beam CT system for musculoskeletal extremities imaging: design, optimization, and initial performance characterization. , 2011, Medical physics.

[11]  J H Siewerdsen,et al.  Statistical reconstruction for cone-beam CT with a post-artifact-correction noise model: application to high-quality head imaging , 2015, Physics in medicine and biology.

[12]  Jeffrey H. Siewerdsen,et al.  Development and clinical translation of a cone-beam CT scanner for high-quality imaging of intracranial hemorrhage , 2017, Medical Imaging.

[13]  S. Schafer,et al.  Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance. , 2011, Medical physics.

[14]  A. Sisniega,et al.  Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions. , 2013, Medical physics.