Dynamic Character Investigation and Optimization of a Novel Air-Source Heat Pump System

Abstract Heating capacity of an air-source heat pump (ASHP) system often decreases when it is operated in winter. This is because of frosting significantly affects the heat transfer efficiency of evaporator, and thus the airflow passage blocked. In order to solve this problem, a novel frost-free ASHP system, integrated with dehumidification and thermal energy storage, has been developed. In this paper, to further investigate the dynamic characteristics of the system working at low temperature, a mathematical model of the novel frost-free ASHP system was constructed. The mathematical model was verified by comparison with experimental data that showed that the measured results were in good accordance with the numerical ones. According to the mathematical model, the research results indicated that, at relatively humidity (RH) of 80%, the system average COP increased by 56.2% when ambient temperature increased from −10 °C to 0 °C. However, it decreased by 6.7% when RH increased from 75% to 85% at temperature of 0 °C. In addition, the system average COP at the air velocity of 3.0 m s −1 was higher 0.22 and 0.16 than that of 2.5 m s −1 and 3.5 m s −1 . Finally, the correlations of the system frost-free working time and the system COP with ambient temperature and relative humidity were obtained, respectively, by multivariate linear regression. These results provided a basis in improving and optimizing the thermal system COP and other main performance parameters.

[1]  Tianshu Ge,et al.  Performance study of silica gel coated fin-tube heat exchanger cooling system based on a developed mathematical model , 2011 .

[2]  Hongxing Yang,et al.  Study on the operating performance of cross hot-gas bypass defrosting system for air-to-water screw heat pumps , 2013 .

[3]  Ni Long,et al.  An experimental study on the operating performance of a novel reverse-cycle hot gas defrosting method for air source heat pumps , 2011 .

[4]  Li Zhang,et al.  Theoretical study on a frost-free household refrigerator-freezer , 2016 .

[5]  S. W. Wang,et al.  A new method for preventing HP from frosting , 2005 .

[6]  Zhang Lin,et al.  Experimental analysis on a novel frost-free air-source heat pump water heater system , 2014 .

[7]  Li Zhang,et al.  Combination of air-source heat pumps with liquid desiccant dehumidification of air , 2012 .

[8]  Byungsoon Kim,et al.  Defrosting method adopting dual hot gas bypass for an air-to-air heat pump , 2011 .

[9]  José Fernández-Seara,et al.  Modelling and experimental validation of the hot-gas defrost process of an air-cooled evaporator , 2010 .

[10]  Zhongliang Liu,et al.  Preparation and anti-frosting performance of super-hydrophobic surface based on copper foil , 2011 .

[11]  G. K. Nathan,et al.  Numerical and experimental studies of refrigerant circuitry of evaporator coils , 2001 .

[12]  Zhongliang Liu,et al.  Experimental study on frost release on fin-and-tube heat exchangers by use of a novel anti-frosting paint , 2009 .

[13]  S. Klein,et al.  NIST Standard Reference Database 23: NIST Thermodynamic and Transport Properties of Refrigerants and Refrigerant Mixtures-REFPROP, Version 6.0 | NIST , 1998 .

[14]  Shiming Deng,et al.  A modeling study on alleviating uneven defrosting for a vertical three-circuit outdoor coil in an air source heat pump unit during reverse cycle defrosting , 2016 .

[15]  Ahmad Pesaran,et al.  Moisture transport in silica gel packed beds—I.Theoretical study , 1987 .

[16]  Li Zhang,et al.  A new method for preventing air-source heat pump water heaters from frosting , 2012 .

[17]  Ju-Suk Byun,et al.  Frost retardation of an air-source heat pump by the hot gas bypass method , 2008 .

[18]  Liang Xia,et al.  A semi-empirical modeling study on the defrosting performance for an air source heat pump unit with local drainage of melted frost from its three-circuit outdoor coil , 2014 .

[19]  Kyung-Min Kwak,et al.  A study on the performance enhancement of heat pump using electric heater under the frosting condition: Heat pump under frosting condition , 2010 .

[20]  Tang Liming,et al.  Analysis on performance of a novel frost-free air-source heat pump system , 2011 .

[21]  T. C. Carnavos Heat Transfer Performance of Internally Finned Tubes in Turbulent Flow , 1980 .

[22]  M. Shah A general correlation for heat transfer during film condensation inside pipes , 1979 .

[23]  Wenming Yang,et al.  Advances in heat pump systems: A review , 2010 .

[24]  S. Touber,et al.  Distributed and non-steady-state modelling of an air cooler , 1991 .

[25]  Dennis L. O'Neal,et al.  Frosting performance of tube fin heat exchangers with wavy and corrugated fins , 1991 .

[26]  Jiang Yiqiang,et al.  A novel defrosting method using heat energy dissipated by the compressor of an air source heat pump , 2014 .

[27]  F. Dittus,et al.  Heat transfer in automobile radiators of the tubular type , 1930 .

[28]  Xiaosong Zhang,et al.  Control strategy and experimental study on a novel defrosting method for air-source heat pump , 2010 .

[29]  Zhang Lin,et al.  Performance investigation of a novel frost-free air-source heat pump water heater combined with energy storage and dehumidification , 2015 .

[30]  Zhao Li,et al.  An experimental study on the uneven refrigerant distribution over a vertically installed multi-circuit outdoor coil in an air source heat pump unit during reverse cycle defrosting , 2015 .

[31]  Jung-Yang San,et al.  Heat and mass transfer in a two-dimensional cross-flow regenerator with a solid conduction effect , 1993 .

[32]  Fu-Yun Zhao,et al.  Dynamic simulation of air-source heat pump during hot-gas defrost , 2003 .

[33]  Ling Yan,et al.  Experimental study on concentration change of spray solution used for a novel non-frosting air source heat pump system , 2014 .

[34]  Minglu Qu,et al.  A study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an air source heat pump – Part I: Experiments , 2012 .