Performance Limits of Three-Phase Self-Excited Induction Generator (SEIG) as a Stand Alone DER

This paper present a unified method of steady state performance analysis and limits characteristics of an autonomous three-phase self-excited induction generator (SEIG) driven by a wind turbine under different types of loads and speeds. The proposed method is based on a new mathematical function to solve for the real and imaginary components of the complex equation of the mathematical model. Performances limits, regulation and characteristics of different configurations will be thoroughly examined and compared. The proposed system will be modeled and simulated and the performance limits characteristics will be compared with variable speed and variable capacity.