Background: The aim of the study was to examine the effect of the angle between optical axis of the endoscope and the instruments’ plane (OAIP) on the monitor display angle (approach angle between the two instruments on a two-dimensional monitor) and endoscopic task performance. Methods: Two experiments were carried out in the Advanced Dundee Endoscopic Psychomotor Tester (ADEPT) using a standard two-dimensional video endoscopic system. In the first experiment, the monitor display angle was measured during use, with OAIP angles ranging between 0 and 80° (at 10° increments) and manipulation angles varying between 45 and 120° (at 15° increments). In the second experiment, 10 surgeons tied 500 intracorporeal knots with OAIP angles of 0° (optical axis in the same plane as the instruments), +15° and +30° (viewing above the instruments’ plane), and −15 and −30° (optical axis looking from below instruments’ plane). The end points were the execution time and knot quality score (KQS). Results: In the first experiment, instruments entered the visual field from lateral sides of the monitor with an apparent 180° monitor display angle with a 0° OAIP angle, whereas the monitor display angle approached the actual manipulation angle between the two needle drivers when an 80° OAIP angle was used. In the second experiment, the instruments appeared to enter the image field from the side of the surgeon when the endoscope viewed the instruments from above, whereas instruments entered the field from the opposite side to the surgeon when the endoscope viewed instruments’ plane from below. As a result, use of 0 and +15° OATP angles yielded significantly shorter execution times: 70 s compared to 83, 93, and 77 s for +30, −30, and −15° OAIP angles (p < 0.001), with KQS of 39° and 40 vs 38, 36, and 34%, respectively (p = 0.257). Conclusions: The angle between the optical axis of the endoscope and instruments’ plane determines how the instruments appear to enter the operative field. The monitor display angle between the instruments is different from the real manipulation angle unless the OAIP angle is near 80°. The apparent entry of instruments into the operative field becomes intuitive for the surgeon only if the endoscope is viewing from above or in the same plane as the instruments. Hence, the best performance for endoscopic knot tying is obtained with this configuration, and execution time increases significantly with viewing from below the instruments’ plane.
[1]
R. McIntyre,et al.
The anterior abdominal wall in laparoscopic procedures and limitations of laparoscopic simulators
,
1996,
Surgical Endoscopy.
[2]
A. Cuschieri,et al.
Influence of the optical axis-to-target view angle on endoscopic task performance
,
1999,
Surgical Endoscopy.
[3]
A Cuschieri,et al.
Objective assessment of endoscopic knot quality.
,
1997,
American journal of surgery.
[4]
A. Cuschieri,et al.
Rocker handle for endoscopic needle drivers
,
1999,
Surgical Endoscopy.
[5]
A. Cuschieri,et al.
Optimal port locations for endoscopic intracorporeal knotting
,
1997,
Surgical Endoscop.
[6]
A. Cuschieri,et al.
Computer-controlled endoscopic performance assessment system
,
1998,
Surgical Endoscopy.