Passive and Active Methods of Islanding Detection for grid Connected PV Distributed Generators

This study proposes a comparison between two islanding detection methods (IDMs) for grid- interconnected distributed generators (DG). The first method is a passive technique based on monitoring the frequency of the system and the rate of change of frequency (ROCOF) at the point of common coupling (PCC).The second method is an active technique based on the injection of a current waveform distortion to the original reference current of the inverter, to force a frequency drift in case of islanding operation. The test results show that there is a difference between the two techniques. Islanding detection methods are investigated, simulated and evaluated in MATLAB / SIMULINK.

[1]  Wilsun Xu,et al.  A Power Line Signaling Based Technique for Anti-Islanding Protection of Distributed Generators—Part I: Scheme and Analysis , 2007, IEEE Transactions on Power Delivery.

[2]  Liuchen Chang,et al.  A New Adaptive Logic Phase-Shift Algorithm for Anti-Islanding Protections in Inverter-Based DG Systems , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[3]  R. Iravani,et al.  Negative-Sequence Current Injection for Fast Islanding Detection of a Distributed Resource Unit , 2008, IEEE Transactions on Power Electronics.

[4]  S. R. Samantaray,et al.  Assessment of ROCPAD Relay for Islanding Detection in Distributed Generation , 2011, IEEE Transactions on Smart Grid.

[5]  H. Kobayashi,et al.  Method for preventing islanding phenomenon on utility grid with a number of small scale PV systems , 1991, The Conference Record of the Twenty-Second IEEE Photovoltaic Specialists Conference - 1991.

[6]  Wen-Yeau Chang A correlation factor based islanding detection method for distributed synchronous generators , 2008 .

[7]  Miles A Redfern,et al.  A new microprocessor based islanding protection algorithm for dispersed storage and generation units , 1995 .

[8]  Jaeho Choi,et al.  Optimal Design of Active Anti-islanding Method Using Digital PLL for Grid-connected Inverters , 2006 .

[9]  Miles A Redfern,et al.  Protection against loss of utility grid supply for a dispersed storage and generation unit , 1993 .

[10]  Wilsun Xu,et al.  A practical method for assessing the effectiveness of vector surge relays for distributed generation applications , 2004, IEEE Transactions on Power Delivery.

[11]  S. J. Huang,et al.  A Detection Algorithm for Islanding-Prevention of Dispersed Consumer-Owned Storage and Generating Units , 2001, IEEE Power Engineering Review.

[12]  Mike Ropp,et al.  Using power line carrier communications to prevent islanding [of PV power systems] , 2000, Conference Record of the Twenty-Eighth IEEE Photovoltaic Specialists Conference - 2000 (Cat. No.00CH37036).

[13]  David Infield,et al.  Predicting islanding operation of grid connected PV inverters , 2000 .

[14]  Seung-Gi Jeong,et al.  Boundary conditions of reactive-power-variation method and active-frequency-drift method for islanding detection of grid-connected photovoltaic inverters , 2005, Conference Record of the Thirty-first IEEE Photovoltaic Specialists Conference, 2005..

[15]  Ajeet Rohatgi,et al.  Analysis and performance assessment of the active frequency drift method of islanding prevention , 1999 .

[16]  H. L. Nakra,et al.  Case study on the integration of a non-utility induction generator to the Hydro-Quebec distribution network , 1995 .

[17]  N. Jenkins,et al.  Loss-of-mains detection for small generators , 1996 .

[18]  Pengwei Du,et al.  Active anti-islanding schemes for synchronous-machine-based distributed generators , 2005 .

[19]  S. I. Jang,et al.  A new islanding detection algorithm for distributed generations interconnected with utility networks , 2004 .

[20]  M. H. Nehrir,et al.  A review of issues regarding the use of distributed generators , 2005 .

[21]  Wilsun Xu,et al.  A Power Line Signaling Based Technique for Anti-islanding Protection of Distributed Generators: Part I: Scheme and Analysis , 2007 .

[22]  B. Fox,et al.  Loss of mains detection for embedded generation by system impedance monitoring , 1997 .

[23]  Zhe Chen,et al.  A hybrid islanding detection technique using average rate of voltage change and real power shift , 2009, 2009 IEEE Power & Energy Society General Meeting.