Charge coupling behavior of double-layer oil-paper insulation under dc and pulse voltages

An oil-paper insulation system which will withstand DC voltage under normal conditions is a key component of converter transformers as well as high voltage direct current (HVDC) bushings. When the system changes its state, operating overvoltage appears. This kind of overvoltage will consequently affect the application of oilimmersed facilities and the safety of entire grid. Therefore, this paper studies the charge coupling behavior of double-layer oil-paper insulation under DC and pulse voltages. From the research of different pulse voltage amplitudes, pulse numbers and polarity, conclusions can be drawn that, with the increase of the pulse voltage amplitudes, DC and pulse voltages in the same polarity cause the absolute value of the initial surface potential to decrease and then rise; while in different polarities, the charge with the same polarity as the pulse voltage increases. Furthermore, for the same pulse voltage, the absolute initial value of the DC voltage applied in the same polarity is higher than that in different polarities. Considering the pulse number effect, it is obvious that the initial value increases with the increase in the pulse number, and then reaches saturation. Also, with the increase in pulse number, the decay rate decreases and thus the charge is slowly dissipated. From the tdV/dt and the decay time curves, the peak value increases with the increase in the pulse number, while the characteristic time varies by the polarity of the DC and pulse voltages.

[1]  L. Dascalescu,et al.  Surface potential decay dynamic characteristics of negative-corona-charged fibrous dielectric materials , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[2]  Toshiyuki Nishi,et al.  Creepage discharge characteristics over solid-liquid interfaces with grounded side electrode , 1996, ICDL'96. 12th International Conference on Conduction and Breakdown in Dielectric Liquids.

[3]  X. Qiu,et al.  Piezoelectric properties and charge dynamics in poly(vinylidene fluoride-hexafluoropropylene) copolymer films with different content of HEP , 2006, IEEE Transactions on Dielectrics and Electrical Insulation.

[4]  T. Han,et al.  Electrical tree characteristics in silicone rubber under repetitive pulse voltage , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[5]  H. Okubo,et al.  Surface charges on alumina in vacuum with varying surface roughness and electric field distribution , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  P. Molinié,et al.  New methodology for surface potential decay measurements: application to study charge injection dynamics on polypropylene films , 2004, IEEE Transactions on Dielectrics and Electrical Insulation.

[7]  E. Schamiloglu,et al.  Experimental study on conduction current of positive nanosecond-pulse diffuse discharge at atmospheric pressure , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[8]  S. Usa,et al.  Impulse Strength of Transformer Insulation With Nonstandard Waveshapes , 2007, IEEE Transactions on Power Delivery.

[9]  B. Du,et al.  Effect of direct fluorination on surface charge of polyimide films using repetitive pulsed power , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[10]  Huang Meng,et al.  Effect of interface on space charge behavior in multi-layer oil-paper insulation , 2012, 2012 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.

[11]  Zhenya Liu,et al.  Ultra-High Voltage AC/DC Grids , 2014 .

[12]  B. Du,et al.  Dynamic behavior of surface charge on direct- fluorinated polyimide films , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[13]  Satoru Yanabu,et al.  Surface Breakdown Characteristics of Silicone Oil for Electric Power Apparatus , 2005 .

[14]  Zhongdong Wang,et al.  Secondary reverse streamer observed in an ester insulating liquid under negative impulse voltage , 2011 .

[15]  Z.D. Wang,et al.  Effect of ageing on the impulse breakdown strength of oil-impregnated pressboard used in power transformers , 2006, 2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena.

[16]  Chi Xiao-Chun,et al.  Creeping discharge performance of oil-paper insulation with streaming electrification , 1997 .

[17]  B. Du,et al.  Effect of nanosecond rise time of pulse voltage on the surface charge of Epoxy/TiO2 nanocomposites , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[18]  R. Liao,et al.  Space charge behavior in multi-layer oil-paper insulation under different DC voltages and temperatures , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.

[19]  P. Watson The energy distribution of localized states in polystyrene, based on isothermal discharge measurements , 1990 .

[20]  P. Molinié Measuring and modeling transient insulator response to charging: the contribution of surface potential studies , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.

[21]  S. Okabe,et al.  Voltage-time and voltage-number characteristics of insulation elements with oil-filled transformers in EHV and UHV classes , 2006, IEEE Transactions on Dielectrics and Electrical Insulation.

[22]  J. Simmons,et al.  Thermally Stimulated Currents in Semiconductors and Insulators Having Arbitrary Trap Distributions , 1973 .

[23]  S. Gubanski,et al.  Charging Characteristics of EPDM and Silicone Rubbers Deduced from Surface Potential Measurements , 2009, IEEE Transactions on Dielectrics and Electrical Insulation.

[24]  B. X. Du,et al.  Interface charge behavior of multi-layer oil–paper insulation under DC and polarity reversal voltages , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.