A harmonic pulse testing method for leakage detection in deep subsurface storage formations

Detection of leakage in deep geologic storage formations (e.g., carbon sequestration sites) is a challenging problem. This study investigates an easy-to-implement frequency domain leakage detection technology based on harmonic pulse testing (HPT). Unlike conventional constant-rate pressure interference tests, HPT stimulates a reservoir using periodic injection rates. The fundamental principle underlying HPT-based leakage detection is that leakage modifies a storage system's frequency response function, thus providing clues of system malfunction. During operations, routine HPTs can be conducted at multiple pulsing frequencies to obtain experimental frequency response functions, using which the possible time-lapse changes are examined. In this work, a set of analytical frequency response solutions is derived for predicting system responses with and without leaks for single-phase flow systems. Sensitivity studies show that HPT can effectively reveal the presence of leaks. A search procedure is then prescribed for locating the actual leaks using amplitude and phase information obtained from HPT, and the resulting optimization problem is solved using the genetic algorithm. For multiphase flows, the applicability of HPT-based leakage detection procedure is exemplified numerically using a carbon sequestration problem. Results show that the detection procedure is applicable if the average reservoir conditions in the testing zone stay relatively constant during the tests, which is a working assumption under many other interpretation methods for pressure interference tests. HPT is a cost-effective tool that only requires periodic modification of the nominal injection rate. Thus it can be incorporated into existing monitoring plans with little additional investment.

[1]  Alexander Y. Sun,et al.  Inversion of pressure anomaly data for detecting leakage at geologic carbon sequestration sites , 2012 .

[2]  P. Kitanidis,et al.  Estimation of historical groundwater contaminant distribution using the adjoint state method applied to geostatistical inverse modeling , 2004 .

[3]  K. Bandilla,et al.  Brine flow up a well caused by pressure perturbation from geologic carbon sequestration: Static and dynamic evaluations , 2011 .

[4]  Alain C. Gringarten From Straight Lines to Deconvolution: The Evolution of the State of the Art in Well Test Analysis , 2008 .

[5]  Mehdi Zeidouni,et al.  Analytical model of well leakage pressure perturbations in a closed aquifer system , 2014 .

[6]  C. Johnson,et al.  Pulse-Testing: A New Method for Describing Reservoir Flow Properties Between Wells , 1966 .

[7]  D. E. Goldberg,et al.  Genetic Algorithms in Search , 1989 .

[8]  P. Kitanidis,et al.  Hydraulic conductivity imaging from 3‐D transient hydraulic tomography at several pumping/observation densities , 2013 .

[9]  Zoran Kapelan,et al.  A review of methods for leakage management in pipe networks , 2010 .

[10]  Stefan Finsterle,et al.  Percolation-theory and fuzzy rule-based probability estimation of fault leakage at geologic carbon sequestration sites , 2010 .

[11]  Jens T. Birkholzer,et al.  Early detection of brine and CO2 leakage through abandoned wells using pressure and surface-deformation monitoring data: Concept and demonstration , 2013 .

[12]  A. Unal,et al.  Transfer functions for nonlinear systems via Fourier-Borel transforms , 1988, 1988., IEEE International Symposium on Circuits and Systems.

[13]  A. Sun,et al.  A constrained robust least squares approach for contaminant release history identification , 2006 .

[14]  Cem B. Avci,et al.  EVALUATION OF FLOW LEAKAGE THROUGH ABANDONED WELLS AND BOREHOLES , 1994 .

[15]  Alain C. Gringarten,et al.  Harmonic Testing for Continuous Well and Reservoir Monitoring , 2002 .

[16]  Todd C. Rasmussen,et al.  Estimating aquifer hydraulic properties using sinusoidal pumping at the Savannah River site, South Carolina, USA , 2003 .

[17]  G. Bruggeman Analytical solutions of geohydrological problems , 1999 .

[18]  Roland N. Horne,et al.  Estimating Permeability Distributions From Pressure Pulse Testing , 2010 .

[19]  Pedro Lee,et al.  Frequency Domain Analysis for Detecting Pipeline Leaks , 2005 .

[20]  Francesca Verga,et al.  Application of harmonic pulse testing to water–oil displacement , 2011 .

[21]  Jens Birkholzer,et al.  Analytical solutions for pressure perturbation and fluid leakage through aquitards and wells in multilayered‐aquifer systems , 2011 .

[22]  Michael Cardiff,et al.  Analytical and Semi‐Analytical Tools for the Design of Oscillatory Pumping Tests , 2015, Ground water.

[23]  Paul A. Witherspoon,et al.  Hydrologic detection of abandoned wells near proposed injection wells for hazardous waste disposal , 1988 .

[24]  J. H. Black,et al.  Determination of hydrogeological parameters using sinusoidal pressure tests: A theoretical appraisal , 1981 .

[25]  Manoj Kumar Tiwari,et al.  Leak detection of pipeline: An integrated approach of rough set theory and artificial bee colony trained SVM , 2012, Expert Syst. Appl..

[26]  Dongxiao Zhang,et al.  Assessing leakage detectability at geologic CO2 sequestration sites using the probabilistic collocation method , 2013 .

[27]  Jiemin Lu,et al.  A Frequency-domain Diagnosis Tool for Early Leakage Detection at Geologic Carbon Sequestration Sites , 2014 .

[28]  Goldberg,et al.  Genetic algorithms , 1993, Robust Control Systems with Genetic Algorithms.

[29]  David Al-Dabass,et al.  Decision support system for water distribution systems based on neural networks and graphs theory for leakage detection , 2012, Expert Syst. Appl..

[30]  M. Celia,et al.  Analytical solutions for leakage rates through abandoned wells , 2004 .

[31]  Bruno Brunone,et al.  Pipe system diagnosis and leak detection by unsteady-state tests. 1. Harmonic analysis , 2003 .

[32]  M. Chaudhry,et al.  Leak detection in pipes by frequency response method using a step excitation , 2001 .

[33]  Bithin Datta,et al.  Optimal Identification of Ground-Water Pollution Sources and Parameter Estimation , 2001 .

[34]  Medhat M. Kamal,et al.  Pressure-Transient Testing of Water-Injection Wells , 1989 .

[35]  Alexander Y. Sun,et al.  Optimal design of pressure-based, leakage detection monitoring networks for geologic carbon sequestration repositories , 2013 .

[36]  Mitchell J. Small,et al.  Probabilistic design of a near-surface CO2 leak detection system. , 2011, Environmental science & technology.

[37]  Alexander Y Sun,et al.  A robust approach for iterative contaminant source location and release history recovery. , 2006, Journal of contaminant hydrology.