A wireless sensor network prototype for post-occupancy troubleshooting of building systems

Abstract The correct commissioning of mechanical and electrical services is critical to new buildings' performance, but there is seldom sufficient time available to complete this skilled-labour intensive task. Accumulated delays from the rest of the project eat into the available time and there can be little left to complete commissioning before the handover. No provision for post-occupancy commissioning would be made either. It is argued that the process would be improved if commissioning engineers had access to good monitoring data, but that the main building energy management system is seldom suitable for this purpose. The practicality and limitations of using a network of wireless sensors as a portable enhanced intensive monitoring regime are explored by constructing and testing a prototype system. On the basis of a deployment in a field trial, a number of design constraints are identified. However, results show the major potential of this approach in post-occupancy commissioning.

[1]  Dino Bouchlaghem,et al.  Predicted vs. actual energy performance of non-domestic buildings: Using post-occupancy evaluation data to reduce the performance gap , 2012 .

[2]  Elmer Morrissey,et al.  Specification and implementation of IFC based performance metrics to support building life cycle assessment of hybrid energy systems , 2004 .

[3]  Andrea Costa,et al.  Building operation and energy performance: Monitoring, analysis and optimisation toolkit , 2013 .

[4]  Jean-Marie Bonnin,et al.  Wireless sensor networks: a survey on recent developments and potential synergies , 2013, The Journal of Supercomputing.

[5]  James Brusey,et al.  Wireless Sensor Networks to Enable the Passive House - Deployment Experiences , 2009, EuroSSC.

[6]  Srinivas Katipamula,et al.  Review Article: Methods for Fault Detection, Diagnostics, and Prognostics for Building Systems—A Review, Part I , 2005 .

[7]  David Fisk,et al.  Development of a Portable Wireless Sensor Network to Enhance Post-Occupancy Commissioning , 2014 .

[8]  David Fisk,et al.  Comparative review of building commissioning regulation: a quality perspective , 2016 .

[9]  Andrew Wheeler,et al.  Commercial Applications of Wireless Sensor Networks Using ZigBee , 2007, IEEE Communications Magazine.

[10]  Federico Domínguez,et al.  Migration from a legacy wireless technology to ZigBee for a Home Automation market ready system , 2012, 2012 Ninth International Conference on Networked Sensing (INSS).

[11]  William M. Healy Lessons Learned in Wireless Monitoring , 2005 .

[12]  Mark Gillott,et al.  Three unobtrusive domestic occupancy measurement technologies under qualitative review , 2014 .

[13]  Bill Bordass,et al.  Making feedback and post-occupancy evaluation routine 2: Soft landings – involving design and building teams in improving performance , 2005 .

[14]  Michael Cw Kintner-Meyer Opportunities of Wireless Sensors and Controls for Building Operation , 2005 .

[15]  David Fisk,et al.  Smart systems commissioning for energy efficient buildings , 2016 .

[16]  Miroslaw J. Skibniewski,et al.  Wireless sensor networks as part of a web-based building environmental monitoring system , 2008 .

[17]  William M. Healy,et al.  Wireless sensor network performance metrics for building applications , 2010 .

[18]  Mike Anderson,et al.  Monitoring-Based Commissioning: Tracking the Evolution and Adoption of a Paradigm-Shifting Approach to Retro-Commissioning , 2012 .

[19]  Jae-Weon Jeong,et al.  Feasibility of wireless measurements for semi-empirical multizone airflow model tuning , 2008 .

[20]  Jiannong Cao,et al.  A middleware for web service-enabled integration and interoperation of intelligent building systems , 2007 .

[21]  Anastasios I. Dounis,et al.  Advanced control systems engineering for energy and comfort management in a building environment--A review , 2009 .

[22]  Gordon Lowry,et al.  Modelling the passive thermal response of a building using sparse BMS data , 2004 .

[23]  Adrian Leaman,et al.  Assessing building performance in use 3: energy performance of the Probe buildings , 2001 .