Relative insensitivity of densitometric stenosis measurement to lumen edge determination.

Coronary artery stenosis measurement from coronary arteriograms is dependent on lumen edge determination. In theory, dependence may be minimized by densitometric integration of the entire lumen as compared with densitometric determination of edges alone coupled with calculation of lumen size by geometric formulas. To assess the impact of approximations of lumen border position when densitometric and geometric methods are employed, external, intermediate and internal borders were defined and used with each method to calculate lumen narrowing from images of contrast-filled, asymmetrically stenotic model vessels and from clinically generated coronary arteriograms. Actual cross-sectional area narrowing of models correlated almost perfectly with densitometric narrowing for each of the three border criteria (external: r = 0.99, n = 192; intermediate: r = 0.99, n = 192; internal: r = 0.99, n = 192). Lumen narrowing calculated by assuming a circular lumen geometry with a diameter equal to the distance between these identical borders correlated less well with true area narrowing (external: r = 0.79, n = 192; intermediate: r = 0.83, n = 192; internal: r = 0.78, n = 192); the residual variance of the densitometric regression was significantly less than that of the geometric regression for each of the three border criteria (external: 8.13 versus 372, p less than 0.001; intermediate: 7.39 versus 315, p less than 0.001; internal: 7.13 versus 531, p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

[1]  R. Dinsmore,et al.  Interobserver Variability in Coronary Angiography , 1976, Circulation.

[2]  S. Paulin,et al.  Computerized image analysis for quantitative measurement of vessel diameter from cineangiograms. , 1983, Circulation.

[3]  R. Kruger,et al.  Vessel diameter measurement using digital subtraction radiography. , 1985, Investigative radiology.

[4]  P D Esser,et al.  Quantification of relative coronary arterial stenosis by cinevideodensitometric analysis of coronary arteriograms. , 1984, Circulation.

[5]  O Nalcioglu,et al.  Videodensitometric determination of minimum coronary artery luminal diameter before and after angioplasty. , 1987, The American journal of cardiology.

[6]  Stuart Berg Flexner,et al.  The Random House Dictionary of the English Language and the Poetry of Tina Darragh , 2020, Dictionary Poetics.

[7]  T Sandor,et al.  Cine-densitometric measurement of coronary arterial stenoses. , 1979, Catheterization and cardiovascular diagnosis.

[8]  M M Bodenheimer,et al.  Quantitation of absolute area of a coronary arterial stenosis: experimental validation with a preparation in vivo. , 1986, Circulation.

[9]  R H Selzer,et al.  Computer assessment of hemodynamic severity of coronary artery stenosis from angiograms. , 1985, Computer methods and programs in biomedicine.

[10]  P. Cohn,et al.  Comparison of observer performance with 16 mm cinefluorography and 70 mm camera fluorography in coronary arteriography. , 1975, The American journal of cardiology.

[11]  E J Topol,et al.  Variability of quantitative digital subtraction coronary angiography before and after percutaneous transluminal coronary angioplasty. , 1987, The American journal of cardiology.

[12]  E. Bolson,et al.  Quantitative Coronary Arteriography: Estimation of Dimensions, Hemodynamic Resistance, and Atheroma Mass of Coronary Artery Lesions Using the Arteriogram and Digital Computation , 1977, Circulation.

[13]  J. Neter,et al.  Applied linear statistical models : regression, analysis of variance, and experimental designs , 1974 .

[14]  T. Takaro,et al.  Observer Agreement in Evaluating Coronary Angiograms , 1975, Circulation.

[15]  Michael H. Kutner Applied Linear Statistical Models , 1974 .

[16]  W. C. Sheldon,et al.  Comparison of stress digital ventriculography, stress thallium scintigraphy, and digital fluoroscopy in the diagnosis of coronary artery disease in subjects without prior myocardial infarction. , 1985, The American journal of cardiology.