Small animal Look-Locker inversion recovery (SALLI) for simultaneous generation of cardiac T1 maps and cine and inversion recovery-prepared images at high heart rates: initial experience.

PURPOSE To develop a single magnetic resonance (MR) imaging approach for comprehensive assessment of cardiac function and tissue properties in small animals with high heart rates. MATERIALS AND METHODS All animal studies were approved by the local animal care committee. Small animal Look-Locker inversion recovery (SALLI) was implemented on a clinical 3.0-T MR unit equipped with a 70-mm solenoid coil. SALLI combines a segmented, electrocardiographically gated, inversion recovery-prepared Look-Locker-type pulse sequence with a multimodal reconstruction framework. Temporal undersampling and radial nonbalanced steady-state free precession enabled acceleration of data acquisition and reduction of motion artifacts, respectively. Nine agarose gel phantoms were used to investigate different sequence settings. For in vivo studies, 10 Sprague-Dawley rats were evaluated to establish normal T1 values before and after injection of gadopentetate dimeglumine. Seven rats with surgically induced acute myocardial infarction were examined to test the feasibility of detecting myocardial injury. In vitro T1 behavior was studied with linear regression analysis, and in vivo T1 differences between infarcted and remote areas were tested by using the Wilcoxon signed rank test. RESULTS Phantom studies demonstrated systematic behavior of the T1 measurements, and T1 error could be reduced to 1.3% ± 7.4 by using a simple linear correction algorithm. The pre- and postcontrast T1 of myocardium and blood showed narrow normal ranges. In the area of infarction, SALLI demonstrated hypokinesia (on cine images), myocardial edema (on precontrast T1 maps), and myocardial necrosis (on postcontrast T1 maps and late gadolinium enhancement images). CONCLUSION An MR imaging method enabling simultaneous generation of cardiac T1 maps and cine and inversion recovery-prepared images at high heart rates is presented. SALLI allows for simultaneous and time-efficient assessment of cardiac T1 behavior, function, and late gadolinium enhancement at high heart rates.

[1]  Osman Ratib,et al.  OsiriX: An Open-Source Software for Navigating in Multidimensional DICOM Images , 2004, Journal of Digital Imaging.

[2]  M. Hayward,et al.  Equilibrium Contrast Cardiovascular Magnetic Resonance for the Measurement of Diffuse Myocardial Fibrosis: Preliminary Validation in Humans , 2010, Circulation.

[3]  M. Schwaiger,et al.  The Future of Cardiovascular Imaging in the Diagnosis and Management of Heart Failure, Part 2: Clinical Applications , 2008, Circulation. Cardiovascular imaging.

[4]  J Hennig,et al.  T1 quantification with inversion recovery TrueFISP , 2001, Magnetic resonance in medicine.

[5]  C. Higgins,et al.  Measurement of the distribution volume of gadopentetate dimeglumine at echo-planar MR imaging to quantify myocardial infarction: comparison with 99mTc-DTPA autoradiography in rats. , 1999, Radiology.

[6]  C. Higgins,et al.  Reperfused rat myocardium subjected to various durations of ischemia: estimation of the distribution volume of contrast material with echo-planar MR imaging. , 2000, Radiology.

[7]  O. Simonetti,et al.  Relationship of MRI delayed contrast enhancement to irreversible injury, infarct age, and contractile function. , 1999, Circulation.

[8]  Katherine C. Wu,et al.  Infarct Tissue Heterogeneity by Magnetic Resonance Imaging Identifies Enhanced Cardiac Arrhythmia Susceptibility in Patients With Left Ventricular Dysfunction , 2007, Circulation.

[9]  R. F. Hoyt,et al.  Cardiac magnetic resonance imaging , 2004, Postgraduate Medical Journal.

[10]  S. Chugh,et al.  Gadolinium-enhanced magnetic resonance imaging for detection and quantification of fibrosis in human myocardium in vitro , 2007, The International Journal of Cardiovascular Imaging.

[11]  David M Higgins,et al.  Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart , 2004, Magnetic resonance in medicine.

[12]  R Deichmann,et al.  Quantification of T1 values by SNAPSHOT-FLASH NMR imaging , 1992 .

[13]  S. Plein,et al.  Myocardial T1 mapping: Application to patients with acute and chronic myocardial infarction , 2007, Magnetic resonance in medicine.

[14]  Krishna S Nayak,et al.  Wideband SSFP: Alternating repetition time balanced steady state free precession with increased band spacing , 2007, Magnetic resonance in medicine.

[15]  B. Schnackenburg,et al.  Angiotensin II Type 2 Receptor Stimulation: A Novel Option of Therapeutic Interference With the Renin-Angiotensin System in Myocardial Infarction? , 2008, Circulation.

[16]  David M Higgins,et al.  Human myocardium: single-breath-hold MR T1 mapping with high spatial resolution--reproducibility study. , 2006, Radiology.

[17]  J. Tyberg,et al.  Edema as a very early marker for acute myocardial ischemia: a cardiovascular magnetic resonance study. , 2009, Journal of the American College of Cardiology.