Cardioversion: past, present, and future.

Simplicity is the ultimate sophistication. — —Leonardo da Vinci Recent years have seen rapid proliferation of ablative and antiarrhythmic therapies for treating various ventricular and supraventricular arrhythmias. Yet cardioversion and defibrillation remain the main modalities to restore normal sinus rhythm. Their simplicity, reliability, safety, and, most important, their efficacy in promptly restoring normal sinus rhythm are unmatched in our current treatment armamentarium. ### The Early Work Contemporary cardiology has been significantly affected by the ready availability of this simple method for terminating atrial and ventricular tachyarrhythmias. However, fascination with electricity and its use in biological systems is hardly contemporary. The first capacitor that was able to store electric energy in a glass container was discovered in 1745. It was named the Leyden jar, and its use was shortly thereafter tested in the electrocution of small animals. There is a large body of literature in Italy, France, and England on biological and medical application of electricity dating from the 17th and 18th centuries. Although physicians across Europe started using electricity as an experimental treatment, the earliest recorded scientific approach with the use of electric shocks was that of Peter Abildgaard in 1775.1 He systematically shocked hens, delivering electric charges in different parts of their body. Electric stimuli applied anywhere across the body of the hen, particularly in the head, could render the animal lifeless, but subsequent shocks delivered to the chest could revive the heart. Abildgaard was only one of the several scientists who studied the effects of electricity on animals. Some reported similar findings, and others could not reproduce his results. However, Luigi Galvani in 1781 first clearly described the link between electricity and its presence in biological systems.2 He was the first to use the term animal electricity , coined after his famous experiments in which he caused the legs of …

[1]  B. Lown,et al.  "Cardioversion" of atrial fibrillation. A report on the treatment of 65 episodes in 50 patients. , 1963, The New England journal of medicine.

[2]  B. Tabatznik,et al.  Standby automatic defibrillator. An approach to prevention of sudden coronary death. , 1970, Archives of internal medicine.

[3]  R. S. Mackay,et al.  Physiological effects of condenser discharges with application to tissue stimulation and ventricular defibrillation. , 1953, Journal of applied physiology.

[4]  P. Tchou,et al.  Transthoracic cardioversion of atrial fibrillation: comparison of rectilinear biphasic versus damped sine wave monophasic shocks. , 2000, Circulation.

[5]  Sinclair-Smith Bc,et al.  Electrical Reversion of Cardiac Arrhythmias , 1972, Southern medical journal.

[6]  M. Wayne,et al.  An automatic cardiac resuscitator for emergency treatment of cardiac arrest. , 1980, Medical instrumentation.

[7]  J. Schuder,et al.  Transthoracic defibrillation of 100 kg calves with bidirectional truncated exponential shocks. , 1984, Transactions - American Society for Artificial Internal Organs.

[8]  W. B. Kouwenhoven,et al.  Resuscitation by countershock , 1933, Electrical Engineering.

[9]  Jerry H. Gold,et al.  Transthoracic Ventricular Defibrillation in the 100 kg Calf with Symmetrical One-Cycle Bidirectional Rectangular Wave Stimuli , 1983, IEEE Transactions on Biomedical Engineering.

[10]  R. Kleiger,et al.  THE TECHNIQUE OF CARDIOVERSION. , 1964, American heart journal.

[11]  G. Botto,et al.  External cardioversion of atrial fibrillation: role of paddle position on technical efficacy and energy requirements , 1999, Heart.

[12]  J. McWilliam Fibrillar Contraction of the Heart , 1887, The Journal of physiology.

[13]  B. Lown,et al.  CARDIOVERSION OF ECTOPIC TACHYCARDIAS , 1963, The American journal of the medical sciences.

[14]  J. Pantridge,et al.  Cardiac arrest after myocardial infarction. , 1966, Lancet.

[15]  H. Wellens,et al.  Cardiac Arrest Outside of a Hospital: How Can We Improve Results of Resuscitation? , 2003, Circulation.

[16]  S. Effert [AUTOMATIC MONITORING EQUIPMENT AND INDICATION FOR IMPLANTATION OF ELECTRICAL PACEMAKERS]. , 1963, Thoraxchirurgie und vaskulare Chirurgie.

[17]  Khomaziuk Ai,et al.  Experimental analysis of pulmonary circulatory disorders in the acute period of myocardial infarct , 1967 .

[18]  F. Loop,et al.  Role of prophylactic anticoagulation for direct current cardioversion in patients with atrial fibrillation or atrial flutter. , 1992, Journal of the American College of Cardiology.

[19]  N P Campbell,et al.  Randomised comparison of electrode positions for cardioversion of atrial fibrillation , 1999, Heart.

[20]  B PELESKA,et al.  Cardiac Arrhythmias Following Condenser Discharges Led Through an Inductance: Comparison with Effects of Pure Condenser Discharges , 1965, Circulation research.

[21]  B. Lown,et al.  Implanted Standby Defibrillators , 1972, Circulation.

[22]  G. Breithardt,et al.  Anterior-posterior versus anterior-lateral electrode positions for external cardioversion of atrial fibrillation: a randomised trial , 2002, The Lancet.

[23]  B. Lown,et al.  New method for terminating cardiac arrhythmias. Use of synchronized capacitor discharge. , 1986, JAMA.

[24]  J B Martins,et al.  Self-adhesive preapplied electrode pads for defibrillation and cardioversion. , 1984, Journal of the American College of Cardiology.

[25]  M. Böhm,et al.  Randomized comparison of anterolateral versus anteroposterior electrode position for biphasic external cardioversion of atrial fibrillation. , 2005, American heart journal.

[26]  R. L. Page,et al.  The Automated External Defibrillator , 2007, Journal of cardiovascular electrophysiology.

[27]  H. Klemm,et al.  Biphasic versus Monophasic Shock for External Cardioversion of Atrial Flutter , 2008, Cardiology.

[28]  D. R. Hooker,et al.  THE CURRENT FLOWING THROUGH THE HEART UNDER CONDITIONS OF ELECTRIC SHOCK , 1932 .

[29]  J. Lesser,et al.  Severe bradycardia following electrical cardioversion for atrial tachyarrhythmias in patients with acute myocardial infarction. , 1990, Chest.

[30]  J. Schuder Completely implanted defibrillator. , 1970, JAMA.

[31]  T. Graboys,et al.  Cardioversion and defibrillation. , 1980, American heart journal.

[32]  Diack Aw,et al.  An automatic cardiac resuscitator for emergency treatment of cardiac arrest. , 1979 .

[33]  A. Adgey,et al.  Electrode pad size, transthoracic impedance and success of external ventricular defibrillation. , 1989, The American journal of cardiology.

[34]  J. Varon,et al.  Resuscitation great. Luigi Galvani and the foundations of electrophysiology. , 2009, Resuscitation.

[35]  O. Orning,et al.  The efficacy of anticoagulant therapy in preventing embolism related to D.C. electrical conversion of atrial fibrillation. , 1969, The American journal of cardiology.

[36]  Tsukerman Bm,et al.  Some debatable problems on electroimpulse therapy of cardiac arrhythmias. , 1966 .

[37]  N. L. Gurvich [Restoration of vital functions of the organism following fatal electric shock]. , 1952, Klinicheskaia meditsina.

[38]  J. Kastor Michel Mirowski and the automatic implantable defibrillator. , 1989, The American journal of cardiology.

[39]  R. Kleiger,et al.  Use of external electric countershock in the treatment of ventricular tachycardia. , 1961, JAMA.

[40]  G. Ewy,et al.  Effectiveness of direct current defibrillation: role of paddle electrode size: II. , 1977, American heart journal.

[41]  R. Kerber,et al.  Factors affecting transthoracic impedance during electrical cardioversion. , 1988, The American journal of cardiology.

[42]  Samuel Wann,et al.  [Guidelines for the management of patients with atrial fibrillation. Executive summary]. , 2006, Revista espanola de cardiologia.

[43]  L. Bossaert,et al.  Fibrillation and defibrillation of the heart. , 1997, British journal of anaesthesia.

[44]  Derek J Dosdall,et al.  Mechanisms of VF maintenance: wandering wavelets, mother rotors, or foci. , 2009, Heart rhythm.

[45]  P. Zoll,et al.  Termination of ventricular fibrillation in man by externally applied electric countershock. , 1956, The New England journal of medicine.

[46]  B. Lown The lost art of healing , 1996 .

[47]  J. Ornato,et al.  ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation--executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Commit , 2006, Journal of the American College of Cardiology.

[48]  M. Mansour,et al.  Mother rotors and fibrillatory conduction: a mechanism of atrial fibrillation. , 2002, Cardiovascular research.

[49]  J A McWilliam,et al.  Electrical Stimulation of the Heart in Man , 1889, British medical journal.

[50]  Gurvich Nl,et al.  Restoration of regular rhythm in the mammalian fibrillating heart. , 1946 .

[51]  A J Camm,et al.  Atrioverter: an implantable device for the treatment of atrial fibrillation. , 1998, Circulation.

[52]  R. Kerber,et al.  Biphasic versus monophasic shock waveform for conversion of atrial fibrillation: the results of an international randomized, double-blind multicenter trial. , 2002, Journal of the American College of Cardiology.

[53]  L. V. Ussenko,et al.  Naum L Gurvich: A pioneer of defibrillation , 2006 .

[54]  E. Plibus Congressional Record , 2006 .

[55]  F. Morady,et al.  Relationship between the spectral characteristics of atrial fibrillation and atrial tachycardias that occur after catheter ablation of atrial fibrillation. , 2009, Heart rhythm.

[56]  James K. Russell,et al.  Multicenter, Randomized, Controlled Trial of 150-J Biphasic Shocks Compared With 200- to 360-J Monophasic Shocks in the Resuscitation of Out-of-Hospital Cardiac Arrest Victims , 2000, Circulation.

[57]  R. Myerburg,et al.  Sudden Cardiac Death: Epidemiology, Transient Risk, and Intervention Assessment , 1993, Annals of Internal Medicine.

[58]  B. Lown,et al.  Electrical conversion of atrial flutter to atrial fibrillation. Flutter mechanism in man. , 1972, British heart journal.

[59]  Gurvich Nl,et al.  Defibrillation of the heart with biphasic electric impulsation , 1967 .

[60]  G. Ewy,et al.  Comparison of paddle electrode pastes used for defibrillation. , 1977, Heart & lung : the journal of critical care.

[61]  C. Beck,et al.  Ventricular fibrillation of long duration abolished by electric shock. , 1947, Journal of the American Medical Association.

[62]  N. L. Gurvich,et al.  Restoration of regular rhythm in the mammalian fibrillating heart. , 1946, American review of Soviet medicine.

[63]  M. Kroll,et al.  Implantable Cardioverter Defibrillator Therapy: The Engineering-Clinical Interface , 2012, Developments in Cardiovascular Medicine.

[64]  Bernard A. Block The congressional record , 1980 .

[65]  B. G. King,et al.  Effect of electric shock on the heart , 1936, Electrical Engineering.

[66]  B B Lerman,et al.  Relation between transcardiac and transthoracic current during defibrillation in humans. , 1990, Circulation research.

[67]  M. Mower,et al.  History of the ICD , 1996 .

[68]  V. Fuster Hurst's the Heart , 1966 .

[69]  R. Kerber,et al.  Elective cardioversion: influence of paddle-electrode location and size on success rates and energy requirements. , 1981, The New England journal of medicine.

[70]  Leora Peltz,et al.  Epicardial Mapping of Chronic Atrial Fibrillation in Patients: Preliminary Observations , 2004, Circulation.

[71]  J. Schuder The Role of an Engineering Oriented Medical Research Group in Developing Improved Methods and Devices for Achieving Ventricular Defibrillation: The University of Missouri Experience , 1993, Pacing and clinical electrophysiology : PACE.

[72]  Jere R. Behrman,et al.  HUNGER AND MALNUTRITION , 2004 .

[73]  M. Josephson,et al.  ELECTROCARDIOGRAPHY Electrocardiographic changes after cardioversion of ventricular arrhythmias , 2005 .

[74]  G. Breithardt,et al.  A trial of self-adhesive patch electrodes and hand-held paddle electrodes for external cardioversion of atrial fibrillation (MOBIPAPA). , 2005, European heart journal.

[75]  G. Ewy,et al.  Effectiveness of direct current defibrillation: role of paddle electrode size. , 1977, American heart journal.

[76]  J S Geddes,et al.  A mobile intensive-care unit in the management of myocardial infarction. , 1967, Lancet.

[77]  R. Kerber,et al.  Determinants of Intracardiac Current in Defibrillation: Experimental Studies in Dogs , 1981, Circulation.

[78]  The Mechanism and Nature of Ventricular Fibrillation , 1941 .

[79]  A. Vishnevsky,et al.  Some debatable problems on electroimpulse therapy of cardiac arrhythmias. , 1966, The Journal of cardiovascular surgery.

[80]  P D Wolf,et al.  Improved defibrillation thresholds with large contoured epicardial electrodes and biphasic waveforms. , 1987, Circulation.

[81]  D. Stillings The first defibrillator? , 1974, Medical progress through technology.

[82]  Tsukerman Bm,et al.  Control of fibrillating arrhythmia by the method of electrical defibrillation of the atrium , 1959 .

[83]  R. Cappato,et al.  A prospective, randomized comparison in humans of defibrillation efficacy of a standard transvenous ICD system with a totally subcutaneous ICD system (The S-ICD® system) , 2005 .

[84]  L. Armstrong Biphasic Versus Monophasic Shock for External Cardioversion of Atrial Flutter: A Prospective, Randomized Trial , 2009 .

[85]  Carl J. Wiggers,et al.  VENTRICULAR FIBRILLATION DUE TO SINGLE, LOCALIZED INDUCTION AND CONDENSER SHOCKS APPLIED DURING THE VULNERABLE PHASE OF VENTRICULAR SYSTOLE , 1940 .

[86]  H. Calkins,et al.  Comparison of a novel rectilinear biphasic waveform with a damped sine wave monophasic waveform for transthoracic ventricular defibrillation. ZOLL Investigators. , 1999, Journal of the American College of Cardiology.