Research the wet gas flow measurement based on dual-throttle device

Abstract In this paper a novel flow measurement device composed of a long throat Venturi tube and a V-cone was proposed to deal with the wet gas flow measurement without separation, and a new metering method was put forward based on the triple differential pressures. The correlations were based on the gas densiometric Froude number, gas–liquid density ratio, and the differential pressure ratios, which were then compared and validated by the laboratory and field tests. The laboratory test results showed that the uncertainty of relative errors for the gas and liquid flow rates were less than 3% and 6%, respectively. The field test results showed that the uncertainty of relative errors for the gas flow rates before correction varied from 5.53% to 11.57%. After correction the uncertainty of relative errors for gas flow rate varied from 1.37% to 3.22% and full-scale error for liquid flow rate was less than ±10%.