Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization.

PURPOSE The authors previously developed the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. The XCAT consisted of highly detailed whole-body models for the standard male and female adult, including the cardiac and respiratory motions. In this work, the authors extend the XCAT beyond these reference anatomies by developing a series of anatomically variable 4D XCAT adult phantoms for imaging research, the first library of 4D computational phantoms. METHODS The initial anatomy of each phantom was based on chest-abdomen-pelvis computed tomography data from normal patients obtained from the Duke University database. The major organs and structures for each phantom were segmented from the corresponding data and defined using nonuniform rational B-spline surfaces. To complete the body, the authors manually added on the head, arms, and legs using the original XCAT adult male and female anatomies. The structures were scaled to best match the age and anatomy of the patient. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from the template XCAT phantom (male or female) to the target patient model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. Each new phantom was refined by checking for anatomical accuracy via inspection of the models. RESULTS Using these methods, the authors created a series of computerized phantoms with thousands of anatomical structures and modeling cardiac and respiratory motions. The database consists of 58 (35 male and 23 female) anatomically variable phantoms in total. Like the original XCAT, these phantoms can be combined with existing simulation packages to simulate realistic imaging data. Each new phantom contains parameterized models for the anatomy and the cardiac and respiratory motions and can, therefore, serve as a jumping point from which to create an unlimited number of 3D and 4D variations for imaging research. CONCLUSIONS A population of phantoms that includes a range of anatomical variations representative of the public at large is needed to more closely mimic a clinical study or trial. The series of anatomically variable phantoms developed in this work provide a valuable resource for investigating 3D and 4D imaging devices and the effects of anatomy and motion in imaging. Combined with Monte Carlo simulation programs, the phantoms also provide a valuable tool to investigate patient-specific dose and image quality, and optimization for adults undergoing imaging procedures.

[1]  Jørgen Arendt Jensen,et al.  Ultrasound imaging and its modeling Chapter for the Springer Verlag book ” Imaging of Complex Media with Acoustic and Seismic Waves ” in the series : ” Topics in Applied Physics ” , 1999 .

[2]  J. Persliden,et al.  Dosimetry for Computed Tomography Examination of Children , 1996 .

[3]  Martin Caon,et al.  Voxel-based computational models of real human anatomy: a review , 2004, Radiation and Environmental Biophysics.

[4]  J J DeMarco,et al.  Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose , 2007, Physics in medicine and biology.

[5]  W. Segars,et al.  4D XCAT phantom for multimodality imaging research. , 2010, Medical physics.

[6]  H Benoit-Cattin,et al.  The SIMRI project: a versatile and interactive MRI simulator. , 2005, Journal of magnetic resonance.

[7]  Nevzat Karabulut,et al.  Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules , 2002, European Radiology.

[8]  Jan Hrbacek,et al.  Ion-recombination correction for different ionization chambers in high dose rate flattening-filter-free photon beams. , 2012, Physics in medicine and biology.

[9]  L. Younes,et al.  On the metrics and euler-lagrange equations of computational anatomy. , 2002, Annual review of biomedical engineering.

[10]  Michael I. Miller,et al.  Landmark matching via large deformation diffeomorphisms , 2000, IEEE Trans. Image Process..

[11]  Irène Buvat,et al.  Monte Carlo simulations in emission tomography and GATE: An overview , 2006 .

[12]  D R Dance,et al.  CT dosimetry: getting the best from the adult Cristy phantom. , 2005, Radiation protection dosimetry.

[13]  Gregory M. Sturgeon,et al.  Patient specific computerized phantoms to estimate dose in pediatric CT , 2009, Medical Imaging.

[14]  Maria Zankl,et al.  Organ Doses for Children from Computed Tomographic Examinations , 1995 .

[15]  William Paul Segars,et al.  Development of a new dynamic NURBS-based cardiac-torso (NCAT) phantom , 2001 .

[16]  Martin Caon,et al.  Monte Carlo Calculated Effective Dose to Teenage Girls from Computed Tomography Examinations , 2000 .

[17]  Michael Sandborg,et al.  CTmod - A toolkit for Monte Carlo simulation of projections including scatter in computed tomography , 2008, Comput. Methods Programs Biomed..

[18]  X. Xu,et al.  Deformable adult human phantoms for radiation protection dosimetry: anthropometric data representing size distributions of adult worker populations and software algorithms , 2010, Physics in medicine and biology.

[19]  Wesley E. Bolch,et al.  Hybrid Patient-Dependent Phantoms Covering Statistical Distributions of Body Morphometry in the U.S. Adult and Pediatric Population , 2009, Proceedings of the IEEE.

[20]  M. Moseley,et al.  Efficient simulation of magnetic resonance imaging with Bloch-Torrey equations using intra-voxel magnetization gradients. , 2006, Journal of magnetic resonance (San Diego, Calif. 1997 : Print).

[21]  H Zaidi,et al.  Relevance of accurate Monte Carlo modeling in nuclear medical imaging. , 1999, Medical physics.

[22]  J Farah,et al.  Construction of an extended library of adult male 3D models: rationale and results , 2011, Physics in medicine and biology.

[23]  Daniel Lodwick,et al.  Hybrid computational phantoms of the 15-year male and female adolescent: applications to CT organ dosimetry for patients of variable morphometry. , 2008, Medical physics.

[24]  Sonographic Evaluation of Resting Gallbladder Volume and Postprandial Emptying in Patients with Gallstones , 1987 .

[25]  M Durigon,et al.  Organ weight in 684 adult autopsies: new tables for a Caucasoid population. , 2001, Forensic science international.

[26]  V. Cassola,et al.  Standing adult human phantoms based on 10th, 50th and 90th mass and height percentiles of male and female Caucasian populations , 2011, Physics in medicine and biology.

[27]  Cynthia B Paschal,et al.  MRI simulator with object-specific field map calculations. , 2004, Magnetic resonance imaging.

[28]  M Caon,et al.  An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations. , 1999, Physics in medicine and biology.

[29]  M H Buonocore,et al.  Monte Carlo validation in diagnostic radiological imaging. , 2000, Medical Physics (Lancaster).

[30]  J. D'hooge,et al.  A fast convolution-based methodology to simulate 2-Dd/3-D cardiac ultrasound images , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[31]  William P. Segars,et al.  A realistic spline-based dynamic heart phantom , 1998 .

[32]  Aiping Ding,et al.  Extension of RPI-adult male and female computational phantoms to obese patients and a Monte Carlo study of the effect on CT imaging dose , 2012, Physics in medicine and biology.

[33]  Gregory M. Sturgeon,et al.  Patient Specific Dosimetry Phantoms Using Multichannel LDDMM of the Whole Body , 2011, Int. J. Biomed. Imaging.

[34]  Mathias Fink,et al.  Imaging of complex media with acoustic and seismic waves , 2002 .

[35]  W P Segars,et al.  Realistic CT simulation using the 4D XCAT phantom. , 2008, Medical physics.

[36]  D. Chan,et al.  Gallbladder contractility and volume characteristics in gallstone dyspepsia. , 2004, World journal of gastroenterology.

[37]  Wesley E Bolch,et al.  Organ and effective doses in pediatric patients undergoing helical multislice computed tomography examination. , 2007, Medical physics.

[38]  Ehsan Samei,et al.  Patient-specific radiation dose and cancer risk estimation in CT: part I. development and validation of a Monte Carlo program. , 2010, Medical physics.

[39]  Ehsan Samei,et al.  Effects of protocol and obesity on dose conversion factors in adult body CT. , 2012, Medical physics.

[40]  W. Paul Segars,et al.  Organ doses, effective doses, and risk indices in adult CT: comparison of four types of reference phantoms across different examination protocols. , 2012, Medical physics.