Accurate resistivity mouse brain mapping using microelectrode arrays.

Electrical impedance spectroscopy measurements were performed in post-mortem mice brains using a flexible probe with an embedded micrometric electrode array. Combined with a peak resistance frequency method this allowed obtaining intrinsic resistivity values of brain tissues and structures with submillimetric resolution. Reproducible resistivity measurements are reported, which allows the resistivity in the cortex, ventricle, fiber tracts, thalamus and basal ganglia to be differentiated. Measurements of brain slices revealed resistivity profiles correlated with the local density of cell bodies hence allowing to discriminate between the different cortical layers. Finally, impedance measurements were performed on a model of cauterized mouse brain evidencing the possibility to measure the spatial extent and the degree of the tissue denaturation due to the cauterization.

[1]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[2]  P. Renaud,et al.  Demonstration of cortical recording using novel flexible polymer neural probes , 2008 .

[3]  David Isaacson,et al.  Electrical Impedance Tomography , 1999, SIAM Rev..

[4]  D. C. Barber,et al.  Three-dimensional electrical impedance tomography , 1996, Nature.

[5]  Patra Charalampaki,et al.  Impedance spectroscopy--an outstanding method for label-free and real-time discrimination between brain and tumor tissue in vivo. , 2013, Biosensors & bioelectronics.

[6]  J. Newman Resistance for Flow of Current to a Disk , 1966 .

[7]  Philippe Renaud,et al.  In Vivo Electrical Impedance Spectroscopy of Tissue Reaction to Microelectrode Arrays , 2009, IEEE Transactions on Biomedical Engineering.

[8]  R. Kawashima,et al.  An evaluation of the conductivity profile in the somatosensory barrel cortex of Wistar rats. , 2010, Journal of neurophysiology.

[9]  Jaakko Malmivuo,et al.  The conductivity of brain tissues: comparison of results in vivo and in vitro measurements , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  Jens Haueisen,et al.  Influence of anisotropic electrical conductivity in white matter tissue on the EEG/MEG forward and inverse solution. A high-resolution whole head simulation study , 2010, NeuroImage.

[11]  K. Djupsund,et al.  Flexible polyimide microelectrode array for in vivo recordings and current source density analysis. , 2007, Biosensors & bioelectronics.

[12]  Viola Rieke,et al.  Clinical applications for magnetic resonance guided high intensity focused ultrasound (MRgHIFU): Present and future , 2013, Journal of medical imaging and radiation oncology.

[13]  George Paxinos,et al.  The Mouse Brain in Stereotaxic Coordinates , 2001 .

[14]  Patricia Brunner,et al.  Direct reconstruction of tissue parameters from differential multifrequency EIT in vivo , 2006, Physiological measurement.

[15]  Shoogo Ueno,et al.  Comparison of current distributions in electroconvulsive therapy and transcranial magnetic stimulation , 2002 .

[16]  Roland Zengerle,et al.  Online Tissue Discrimination for Transcutaneous Needle Guidance Applications Using Broadband Impedance Spectroscopy , 2012, IEEE Transactions on Biomedical Engineering.

[17]  William E. Lorensen,et al.  Image guidance techniques for neurosurgery , 1994, Other Conferences.

[18]  P. Nicholson,et al.  Specific impedance of cerebral white matter. , 1965, Experimental neurology.

[19]  J. B. Ranck,et al.  THE SPECIFIC IMPEDANCE OF THE DORSAL COLUMNS OF CAT: AN INISOTROPIC MEDIUM. , 1965, Experimental neurology.

[20]  Study of Insertion Characteristics of Si Neural Probe with Sharpened Tip for Minimally Invasive Insertion to Brain , 2013 .

[21]  Sverre Grimnes,et al.  Impedance-based tissue discrimination for needle guidance , 2009, Physiological measurement.

[22]  Robert W. Dykes,et al.  Conductivity in the somatosensory cortex of the cat — evidence for cortical anisotropy , 1979, Brain Research.

[23]  F. Andermann,et al.  Hypothalamic hamartomas. Part 2. Surgical considerations and outcome. , 2013, Neurosurgical focus.

[24]  N. Logothetis,et al.  In Vivo Measurement of Cortical Impedance Spectrum in Monkeys: Implications for Signal Propagation , 2007, Neuron.

[25]  William Shain,et al.  Effects of Glial Cells on Electrode Impedance Recorded from Neural Prosthetic Devices In Vitro , 2010, Annals of Biomedical Engineering.

[26]  P. Tresco,et al.  Response of brain tissue to chronically implanted neural electrodes , 2005, Journal of Neuroscience Methods.

[27]  R. Goodman,et al.  Advances in Surgical Options for Medically Refractory Epilepsy , 2012 .

[28]  C. Elger,et al.  Reoperation after failed resective epilepsy surgery , 2013, Seizure.

[29]  H. Zhang,et al.  Evaluation of Radiofrequency Ablation as an Alternative for the Treatment of Brain Tumor in Rabbits , 2004, Journal of Neuro-Oncology.

[30]  Bryon A. Mueller,et al.  A New Method to Derive White Matter Conductivity From Diffusion Tensor MRI , 2008, IEEE Transactions on Biomedical Engineering.

[31]  I. Gill,et al.  Radiofrequency ablation of the kidney: acute and chronic histology in porcine model. , 2000, Urology.

[32]  J. Latikka,et al.  Conductivity of living intracranial tissues. , 2001, Physics in medicine and biology.

[33]  Jian-Zhong Bao,et al.  Complex dielectric measurements and analysis of brain tissues in the radio and microwave frequencies , 1997 .

[34]  D. Singman Preliminary Evaluation of Ceria‐Lanthana as a Solid Electrolyte for Fuel Cells , 1966 .

[35]  Albert Lee,et al.  Accuracy of deep brain stimulation electrode placement using intraoperative computed tomography without microelectrode recording. , 2013, Journal of neurosurgery.

[36]  Yoshinobu Honkura,et al.  Super MI sensor: recent advances of amorphous wire and CMOS-IC magneto-impedance sensor. , 2012, Journal of nanoscience and nanotechnology.

[37]  Hermann Scharfetter,et al.  Detection of brain oedema using magnetic induction tomography: a feasibility study of the likely sensitivity and detectability. , 2004, Physiological measurement.

[38]  P. Renaud,et al.  Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activity. , 2004, Biosensors & bioelectronics.

[39]  MR imaging-guided cryoablation of metastatic brain tumours: initial experience in six patients , 2010, European Radiology.

[40]  L. Ward,et al.  Automated criterion-based analysis for Cole parameters assessment from cerebral neonatal electrical bioimpedance spectroscopy measurements , 2012, Physiological measurement.

[41]  Successful deep brain stimulation surgery with intraoperative magnetic resonance imaging on a difficult neuroacanthocytosis case: case report. , 2013, Neurosurgery.

[42]  David R. Wozny,et al.  The electrical conductivity of human cerebrospinal fluid at body temperature , 1997, IEEE Transactions on Biomedical Engineering.