The reliability of Predicted Mean Vote model predictions in an air-conditioned mosque during daily prayer times in Malaysia

A field study was conducted to investigate the relationship between the estimated Predicted Mean Vote (PMV) for comfort and the actual measured climate data and occupant comfort sensations recorded in an air-conditioned mosque building in Malaysia. The study was conducted between November 2012 and April 2013 during the five daily periods of prayer. PMV was calculated using the Fanger equations while the Actual Mean Vote (AMV) was gathered from the survey data of 330 randomly selected worshippers. The results show that the thermal responses from worshippers during the five daily prayer periods largely recorded in the neutral zone. PMV model calculations underestimated the temperatures at which people could be comfortable (25.9°C) in the mosque when compared to the AMV of respondents at 30.4°C. The difference of 4.6 K between PMV and AMV indicates that ASHRAE Standard-55 is considerable and obviously has serious energy implications for this organization if temperatures were to be kept at the PMV-required temperatures. It was concluded that worshippers in this air-conditioned mosque located in the hot and humid climate of Malaysia found the indoor thermal conditions to be thermally acceptable at the temperatures they experienced.

[1]  Chungyoon Chun,et al.  Thermal comfort in Japanese schools , 2003 .

[2]  Rahman Saidur,et al.  Energy consumption, energy savings, and emission analysis in Malaysian office buildings , 2009 .

[3]  P. Fanger,et al.  Extension of the PMV model to non-air-conditioned buildings in warm climates , 2002 .

[4]  Ruey Lung Hwang,et al.  Patient thermal comfort requirement for hospital environments in Taiwan , 2007 .

[5]  José A. Orosa,et al.  A new thermal comfort approach comparing adaptive and PMV models , 2011 .

[6]  Mohammad S. Al-Homoud,et al.  Assessment of monitored energy use and thermal comfort conditions in mosques in hot-humid climates , 2009 .

[7]  Kamaruzzaman Sopian,et al.  Thermal comfort assessment of large-scale hospitals in tropical climates: A case study of University Kebangsaan Malaysia Medical Centre (UKMMC) , 2013 .

[8]  Liwei Tian,et al.  Field study on occupants’ thermal comfort and residential thermal environment in a hot-humid climate of China , 2007 .

[9]  Mohd Nasrun Mohd Nawi,et al.  Assessment of thermal comfort in the mosque in Sarawak,Malaysia , 2014 .

[10]  S. Sekhar,et al.  Indoor air quality and thermal comfort studies of an under-floor air-conditioning system in the tropics , 2002 .

[11]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[12]  Michael A. Humphreys,et al.  ADAPTIVE THERMAL COMFORT AND SUSTAINABLE THERMAL STANDARDS FOR BUILDINGS , 2002 .

[13]  Gook-Sup Song,et al.  Air conditioner operation behaviour based on students' skin temperature in a classroom. , 2012, Applied ergonomics.

[14]  Dennis L. Loveday,et al.  Indoor thermal conditions and thermal comfort in air-conditioned domestic buildings in the dry-desert climate of Kuwait , 2010 .

[15]  Hasan-Uddin Khan,et al.  The Mosque and the Modern World: Architects, Patrons and Designs Since the 1950s , 1997 .

[16]  Mohd Nafiz Shaharon,et al.  Thermal Comfort Assessment-A Study Toward Workers Satisfaction in a Low Energy Office Building , 2012 .

[17]  Gail Brager,et al.  Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55 , 2002 .

[18]  J. F. Nicol,et al.  Adaptive comfort , 2011 .

[19]  Ahmad Rasdan Ismail,et al.  Thermal Comfort Assessment: A Case Study at Malaysian Automotive Industry , 2009 .

[20]  C. Chu,et al.  Enthalpy estimation for thermal comfort and energy saving in air conditioning system , 2008 .

[21]  Farraj F. Al-ajmi,et al.  Thermal comfort in air-conditioned mosques in the dry desert climate , 2010 .

[22]  Filip Descamps,et al.  Thermal comfort of patients: Objective and subjective measurements in patient rooms of a Belgian hea , 2011 .

[23]  D. Ishak,et al.  Technical review of wind energy potential as small-scale power generation sources in Penang Island Malaysia , 2012 .

[24]  Li Zheng,et al.  Indoor thermal comfort characteristics under the control of a direct expansion air conditioning unit having a variable-speed compressor and a supply air fan , 2009 .