Review of the application of the open-source software CilOCT for semi-automatic segmentation and analysis of the ciliary muscle in OCT images

Presbyopia and myopia research shows a growing interest in ciliary muscle biometry using optical coherence tomography (OCT). Until now, segmentation of the ciliary muscle is often performed manually using either custom-developed programs or image processing software. Here we present a novel software for semi-automatic segmentation of the ciliary muscle. It provides direct import of OCT images in DICOM format, a standardized procedure for segmentation, image distortion correction, the export of anatomical ciliary muscle landmarks, like ciliary muscle apex and scleral spur, as well as a continuous thickness profile of the ciliary muscle as a novel way of analysis. All processing steps are stored as XML files, fostering documentation and reproducibility of research through the possibility of replicating the analysis. Additionally, CilOCT supports batch processing for the automated analysis of large numbers of images and the respective data export to tabulated text files based on the stored XML files. CilOCT was successfully applied in several studies and their results will be summarized in this paper.

[1]  Leon N Davies,et al.  In vivo analysis of ciliary muscle morphologic changes with accommodation and axial ametropia. , 2010, Investigative ophthalmology & visual science.

[2]  Leon N Davies,et al.  A program to analyse optical coherence tomography images of the ciliary muscle. , 2015, Contact lens & anterior eye : the journal of the British Contact Lens Association.

[3]  J. Zhao,et al.  Ciliary muscle morphology and accommodative lag in hyperopic anisometropic children , 2020, International Ophthalmology.

[4]  Chiu-Yen Kao,et al.  Changes in Ciliary Muscle Thickness During Accommodation in Children , 2012, Optometry and vision science : official publication of the American Academy of Optometry.

[5]  Paul Nagy,et al.  Benefits of Using the DCM4CHE DICOM Archive , 2007, Journal of Digital Imaging.

[6]  A. Welch,et al.  Optical properties of conjunctiva, sclera, and the ciliary body and their consequences for transscleral cyclophotocoagulation. , 1996, Applied optics.

[7]  K. Naidoo,et al.  Global Prevalence of Myopia and High Myopia and Temporal Trends from 2000 through 2050. , 2016, Ophthalmology.

[8]  Leon N Davies,et al.  The effect of ageing on in vivo human ciliary muscle morphology and contractility. , 2011, Investigative ophthalmology & visual science.

[9]  H. G. Rylander,et al.  Optical properties of conjunctiva, sclera, and the ciliary body and their consequences for transscleral cyclophotocoagulation: erratum. , 1997, Applied optics.

[10]  J L Semmlow,et al.  Age-related changes in human ciliary muscle and lens: a magnetic resonance imaging study. , 1999, Investigative ophthalmology & visual science.

[11]  B. Gilmartin,et al.  Ocular biometric correlates of ciliary muscle thickness in human myopia , 2013, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[12]  Loraine T Sinnott,et al.  Ciliary body thickness and refractive error in children. , 2008, Investigative ophthalmology & visual science.

[13]  John P. A. Ioannidis,et al.  What does research reproducibility mean? , 2016, Science Translational Medicine.

[14]  Sandra Wagner,et al.  Ciliary muscle thickness profiles derived from optical coherence tomography images. , 2018, Biomedical optics express.

[15]  R. Montés-Micó,et al.  Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography. , 2019, Arquivos brasileiros de oftalmologia.

[16]  E. Zrenner,et al.  Emmetropes and myopes differ little in their accommodation dynamics but strongly in their ciliary muscle morphology , 2019, Vision Research.

[17]  R. Peng Reproducible Research in Computational Science , 2011, Science.

[18]  Fabrice Manns,et al.  Biometry of the ciliary muscle during dynamic accommodation assessed with OCT , 2014, Photonics West - Biomedical Optics.

[19]  Chiu-Yen Kao,et al.  Semiautomatic Extraction Algorithm for Images of the Ciliary Muscle , 2011, Optometry and vision science : official publication of the American Academy of Optometry.

[20]  Adrian Glasser,et al.  Quantification of age-related and per diopter accommodative changes of the lens and ciliary muscle in the emmetropic human eye. , 2013, Investigative ophthalmology & visual science.

[21]  S. Strenk,et al.  Magnetic resonance imaging of the anteroposterior position and thickness of the aging, accommodating, phakic, and pseudophakic ciliary muscle , 2010, Journal of cataract and refractive surgery.

[22]  Fabrice Manns,et al.  Variability of manual ciliary muscle segmentation in optical coherence tomography images. , 2018, Biomedical optics express.

[23]  F. Schaeffel,et al.  Prolonged nearwork affects the ciliary muscle morphology. , 2019, Experimental eye research.

[24]  M. Campbell,et al.  Presbyopia and the optical changes in the human crystalline lens with age , 1998, Vision Research.

[25]  J. Sivak,et al.  Age-Related Changes in Human Ciliary Muscle , 2000, Optometry and vision science : official publication of the American Academy of Optometry.

[26]  R. Montés-Micó,et al.  Non-invasive measurements of the dynamic changes in the ciliary muscle, crystalline lens morphology, and anterior chamber during accommodation with a high-resolution OCT , 2017, Graefe's Archive for Clinical and Experimental Ophthalmology.

[27]  S. Pizer,et al.  An evaluation of the effectiveness of adaptive histogram equalization for contrast enhancement. , 1988, IEEE transactions on medical imaging.

[28]  Marcella Q. Salomão,et al.  Ciliary Muscle Electrostimulation to Restore Accommodation in Patients With Early Presbyopia: Preliminary Results. , 2017, Journal of refractive surgery.

[29]  Oliver Stachs,et al.  Monitoring accommodative ciliary muscle function using three-dimensional ultrasound , 2002, Graefe's Archive for Clinical and Experimental Ophthalmology.

[30]  Martin Dostál,et al.  User acceptance of the microsoft Ribbon user interface , 2010 .