Specific gamma-ray constant and exposure rate constant of 192Ir.
暂无分享,去创建一个
Calculated values of the 192Ir specific gamma-ray constant, Gamma range from the low value of 3.948 R cm2h-1mCi-1 recommended in NCRP No. 41 to a high of 4.89 R cm2h-1mCi-1. Measured values of Gamma range only from 4.85 to 5.0 Rcm2h-1mCi-1. Discrepancies in reported calculated values exist because the isotope decay scheme and other nuclear spectroscopy data pertinent to these calculations were not well known. Using the 28 gamma rays and relative intensities from the most recent Evaluated Nuclear Structure Data File (ENSDF), Gamma is calculated to be 4.62 +/- 0.05 Rcm2h-1mCi-1 and the exposure rate constant Gamma delta is 4.69 +/- 0.05 Rcm2h-1mCi-1. These new calculations are presented and previously reported values of Gamma and Gamma delta are reviewed.