Extraction of cardiac and respiration signals in electrical impedance tomography based on independent component analysis

Abstract Electrical Impedance Tomography (EIT) has successive wide range in impedance imaging, but still it is difficult to extract cardiac-related conductivity changes and respiratory-related conductivity changes in spontaneous breathing subjects. Quite a few methods are attempted to extract these two signals such as electrocardiogram gated averaging, frequency domain filtering and principal component analysis. However, such methods are not able to take apart these components properly or put some effort in real time imaging and have their own limitations. The purpose of this paper is to introduce a new method in the EIT clinical application field, Independent Component Analysis (ICA) to extract cardiac and respiratory related signals in electrical impedance tomography. Independent component analysis has been introduced to use in electrical impedance tomography but this is the first attempt ever to implement this method to separate these two signals and image those independent conductivity distribution of respiration and cardiac changes independently. Data has been collected from a spontaneous breathing subject. Filtration technique has been used to remove random noise and multi level spatial ICA has been applied to obtain independent component signals which has been later used in reconstruction algorithm for imaging.

[1]  L. Zhukov,et al.  Independent component analysis for EEG source localization , 2000, IEEE Engineering in Medicine and Biology Magazine.

[2]  Ganesh R. Naik,et al.  An Overview of Independent Component Analysis and Its Applications , 2011, Informatica.

[3]  Aapo Hyvärinen,et al.  A Fast Fixed-Point Algorithm for Independent Component Analysis , 1997, Neural Computation.

[4]  B. M. Eyuboglu,et al.  In vivo imaging of cardiac related impedance changes , 1989, IEEE Engineering in Medicine and Biology Magazine.

[5]  S Leonhardt,et al.  Protective ventilation using electrical impedance tomography , 2007, Physiological measurement.

[6]  D C Barber,et al.  Fast reconstruction of resistance images. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[7]  B H Brown,et al.  A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboli. , 1994, Physiological measurement.

[8]  Peter Herrmann,et al.  Regional Lung Perfusion as Determined by Electrical Impedance Tomography in Comparison With Electron Beam CT Imaging , 2002, IEEE Transactions on Medical Imaging.

[9]  Christopher R. Johnson,et al.  INDEPENDENT COMPONENT ANALYSIS FOR EEG SOURCE LOCALIZATION IN REALISTIC HEAD MODELS , 1999 .

[10]  Caroline A Grant,et al.  Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography , 2011, Critical care.

[11]  Inéz Frerichs,et al.  Assessment of Changes in Distribution of Lung Perfusion by Electrical Impedance Tomography , 2009, Respiration.

[12]  T. Faes,et al.  Electrical impedance tomography to measure pulmonary perfusion: is the reproducibility high enough for clinical practice? , 2003, Physiological measurement.

[13]  D. Chakrabarti,et al.  A fast fixed - point algorithm for independent component analysis , 1997 .

[14]  B H Brown,et al.  The Sheffield data collection system. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[15]  A Thiagalingam,et al.  A review on electrical impedance tomography for pulmonary perfusion imaging , 2012, Physiological measurement.

[16]  Gerhard Hellige,et al.  Detection of local lung air content by electrical impedance tomography compared with electron beam CT. , 2002, Journal of applied physiology.

[17]  D C Barber,et al.  An assessment of dynamic images by applied potential tomography for monitoring pulmonary perfusion. , 1988, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[18]  Anton Vonk-Noordegraaf,et al.  Assessment of the Pulmonary Volume Pulse in Idiopathic Pulmonary Arterial Hypertension by Means of Electrical Impedance Tomography , 2006, Respiration.

[19]  O. Hoekstra,et al.  Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning. , 1998, Physiological measurement.

[20]  Steffen Leonhardt,et al.  Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography , 2008, Intensive Care Medicine.

[21]  Peimin Yan,et al.  Using independent component analysis for electrical impedance tomography , 2004, IS&T/SPIE Electronic Imaging.

[22]  R Pikkemaat,et al.  Separation of ventilation and perfusion related signals within EIT-data streams , 2010 .

[23]  Gerhard Hellige,et al.  Funktionelle elektrische Impedanztomographie , 2005 .

[24]  S Leonhardt,et al.  Dynamic separation of pulmonary and cardiac changes in electrical impedance tomography , 2008, Physiological measurement.