A New Method for Generating Poroelastograms in Noisy Environments

Poroelastography has been recently introduced as a new elastographic technique that may be used to describe the spatial and temporal behavior of poroelastic materials. The experimental methodology proposed thus far for phantoms and tissues in vitro requires the acquisition of a precompression rf frame, the application of a unit step strain compression to the sample and the acquisition of subsequent post-compression frames from the material. Elastograms and poroelastograms are generated by cross-correlating the sequentially-acquired postcompression frames with the reference precompression frame. The application of poroelastography to tissues in vivo must address the echo decorrelation problems that are encountered due to uncontrolled tissue motion, which may become significant shortly after the acquisition of the precompression frame. In this paper, we investigate the feasibility of performing poroelastography experiments using an alternative experimental scheme. In the proposed experimental methodology, the reference precompression frame is continuously moved while the time interval between the frames that are correlated is kept short. This allows long data acquisition times with simultaneous minimization of the decorrelation due to undesired tissue motion in vivo. We validated this new method using both a step and a ramp compression functions. We performed poroelastographic simulations and experiments in phantoms and in tissues in vivo. The results were compared to those obtained using the traditional acquisition methodology. This study shows that the two methods yield similar results in vitro and suggests that the new method may be more robust to decorrelation noise in applications in vivo.

[1]  Juha Töyräs,et al.  Prediction of biomechanical properties of articular cartilage with quantitative magnetic resonance imaging. , 2004, Journal of biomechanics.

[2]  S. Ödman,et al.  Noninvasive method for the assessment of subcutaneous oedema , 1986, Medical and Biological Engineering and Computing.

[3]  J Ophir,et al.  Elastographic Imaging Using Staggered Strain Estimates , 2002, Ultrasonic imaging.

[4]  A. Anderson,et al.  The relationship of problems in biomedical MRI to the study of porous media. , 2001, Magnetic resonance imaging.

[5]  V. Mow,et al.  Biphasic creep and stress relaxation of articular cartilage in compression? Theory and experiments. , 1980, Journal of biomechanical engineering.

[6]  Jonathan Ophir,et al.  A method for generating permeability elastograms and Poisson's ratio time-constant elastograms. , 2005, Ultrasound in medicine & biology.

[7]  I. Kiviranta,et al.  Novel mechano-acoustic technique and instrument for diagnosis of cartilage degeneration. , 2002, Physiological measurement.

[8]  V C Mow,et al.  On the fundamental fluid transport mechanisms through normal and pathological articular cartilage during function - II. The analysis, solution and conclusions. , 1976, Journal of biomechanics.

[9]  V C Mow,et al.  On the fundamental fluid transport mechanisms through normal and pathological articular cartilage during function--I. The formulation. , 1976, Journal of biomechanics.

[10]  Y P Zheng,et al.  An ultrasonic measurement for in vitro depth-dependent equilibrium strains of articular cartilage in compression. , 2002, Physics in medicine and biology.

[11]  T. Krouskop,et al.  Poroelastography: imaging the poroelastic properties of tissues. , 2001, Ultrasound in medicine & biology.

[12]  Jonathan Ophir,et al.  Dynamic measurement of internal solid displacement in articular cartilage using ultrasound backscatter. , 2003, Journal of biomechanics.

[13]  Paolo A. Netti,et al.  A poroelastic model for interstitial pressure in tumors , 1995 .

[14]  A Shirazi-Adl,et al.  Investigation of mechanical behavior of articular cartilage by fibril reinforced poroelastic models. , 2003, Biorheology.

[15]  I Céspedes,et al.  Noise reduction in elastograms using temporal stretching with multicompression averaging. , 1996, Ultrasound in medicine & biology.

[16]  A F Mak,et al.  The apparent viscoelastic behavior of articular cartilage--the contributions from the intrinsic matrix viscoelasticity and interstitial fluid flows. , 1986, Journal of biomechanical engineering.

[17]  B. Garra,et al.  Elastography of breast lesions: initial clinical results. , 1997, Radiology.

[18]  Julius S. Bendat,et al.  Random Data - Analysis and Measurement Procedures - Second Edition (revised and expanded) , 1986 .

[19]  J. Buckwalter,et al.  Interspecies comparisons of in situ intrinsic mechanical properties of distal femoral cartilage , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[20]  J Ophir,et al.  Analysis of an Adaptive Strain Estimation Technique in Elastography , 2002, Ultrasonic imaging.

[21]  H Ermert,et al.  New real-time strain imaging concepts using diagnostic ultrasound. , 2000, Physics in medicine and biology.

[22]  Karol Miller,et al.  Brain mechanics For neurosurgery: modeling issues , 2002, Biomechanics and modeling in mechanobiology.

[23]  Jonathan Ophir,et al.  Visualisation of HIFU lesions using elastography of the human prostate in vivo: preliminary results. , 2003, Ultrasound in medicine & biology.

[24]  T. Krouskop,et al.  Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues , 1999, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[25]  C. S. Spalding,et al.  In vivo real-time freehand palpation imaging. , 2003, Ultrasound in medicine & biology.

[26]  Jonathan Ophir,et al.  The feasibility of using elastography for imaging the Poisson's ratio in porous media. , 2004, Ultrasound in medicine & biology.

[27]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[28]  E B Hunziker,et al.  Optical and mechanical determination of Poisson's ratio of adult bovine humeral articular cartilage. , 1997, Journal of biomechanics.

[29]  W M Lai,et al.  An analysis of the unconfined compression of articular cartilage. , 1984, Journal of biomechanical engineering.

[30]  W M Lai,et al.  Fluid transport and mechanical properties of articular cartilage: a review. , 1984, Journal of biomechanics.

[31]  L. Mockros,et al.  Indentation tests of human articular cartilage. , 1976, Journal of biomechanics.