Effects of power reserve control on wind turbine structural loading

As the penetration of wind energy in worldwide electrical utility grids increases, there is a growing interest in the provision of active power control (APC) services from wind turbines and power plants to aid in maintaining grid stability. Recent research has focused on the design of active power controllers for wind turbines that can provide a range of APC services including inertial, primary frequency and secondary frequency control. An important consideration for implementing these controllers in practice is assessing their impact on the lifetime of wind turbine components. In this paper, the impact on the structural loads of a wind turbine providing a power reserve is explored by performing a load suite analysis for several torque-based control strategies. Power reserve is required for providing those APC services that require the ability of the wind turbine to supply an increase in power. To study this, we performed a load suite on a simulated model of a research turbine located at the National Wind Technology Center at the National Renewable Energy Laboratory. Analysis of the results explores the effect of the different reserve strategies on turbine loading. In addition, field-test data from the turbine itself are presented to augment and support the findings from the simulation study results. Results indicate that all power-reserve strategies tend to decrease extreme loads and increase pitch actuation. Fatigue loads tend to be reduced in faster winds and increased in slower winds, but are dependent on reserve-controller design. Copyright © 2015 John Wiley & Sons, Ltd.

[1]  Vahan Gevorgian,et al.  Market Designs for the Primary Frequency Response Ancillary Service—Part I: Motivation and Design , 2014, IEEE Transactions on Power Systems.

[2]  Scott J. Johnson,et al.  Balancing fatigue damage and turbine performance through innovative pitch control algorithm , 2012 .

[3]  J. Jonkman,et al.  Definition of a 5-MW Reference Wind Turbine for Offshore System Development , 2009 .

[4]  Paul Fleming,et al.  Resonant Vibrations Resulting from the Re-Engineering of a Constant-Speed 2-Bladed Turbine to a Variable-Speed 3-Bladed Turbine , 2010 .

[5]  Poul Ejnar Sørensen,et al.  Grid support of a wind farm with active stall wind turbines and AC grid connection , 2006 .

[6]  Alan G. Isemonger,et al.  The evolving design of RTO ancillary service markets , 2009 .

[7]  Damian Flynn,et al.  System-wide inertial response from fixed speed and variable speed wind turbines , 2011, 2011 IEEE Power and Energy Society General Meeting.

[8]  Nicholas W. Miller,et al.  Eastern Frequency Response Study , 2013 .

[9]  Jonathan White,et al.  Structural health and prognostics management for the enhancement of offshore wind turbine operations and maintenance strategies , 2014 .

[10]  Joseph H. Eto,et al.  Use of Frequency Response Metrics to Assess the Planning and Operating Requirements for Reliable Integration of Variable Renewable Generation , 2011 .

[11]  Shun-Hsien Huang,et al.  System Inertial Frequency Response estimation and impact of renewable resources in ERCOT interconnection , 2011, 2011 IEEE Power and Energy Society General Meeting.

[12]  Kathryn E. Johnson,et al.  A tutorial of wind turbine control for supporting grid frequency through active power control , 2012, 2012 American Control Conference (ACC).

[13]  Stavros A. Papathanassiou,et al.  A review of grid code technical requirements for wind farms , 2009 .

[14]  Luis Marroyo,et al.  Method to enable variable speed wind turbine primary regulation , 2009, 2009 International Conference on Power Engineering, Energy and Electrical Drives.

[15]  Badrul H. Chowdhury,et al.  Working towards frequency regulation with wind plants: Combined control approaches , 2010 .

[16]  A. Buckspan,et al.  Combining droop curve concepts with control systems for wind turbine active power control , 2012, 2012 IEEE Power Electronics and Machines in Wind Applications.

[17]  Jan Pierik,et al.  Inertial response of variable speed wind turbines , 2006 .

[18]  Herbert J. Sutherland,et al.  On the Fatigue Analysis of Wind Turbines , 1999 .

[19]  Mohit Singh,et al.  Active Power Controls from Wind Power: Bridging the Gaps , 2014 .

[20]  Kathryn E. Johnson,et al.  Tutorial of Wind Turbine Control for Supporting Grid Frequency through Active Power Control: Preprint , 2012 .

[21]  S. Virmani Security impacts of changes in governor response , 1999, IEEE Power Engineering Society. 1999 Winter Meeting (Cat. No.99CH36233).

[22]  Kathryn E. Johnson,et al.  Comparison and testing of power reserve control strategies for grid‐connected wind turbines , 2014 .

[23]  Nicholas Jenkins,et al.  Power system frequency response from fixed speed and doubly fed induction generator-based wind turbines , 2004 .

[24]  Paul Fleming,et al.  An Active Power Control System for Wind Turbines Capable of Primary and Secondary Frequency Control for Supporting Grid Reliability , 2013 .

[25]  E. Ela,et al.  Participation of Wind Power in LMP-Based Energy Markets , 2012, IEEE Transactions on Sustainable Energy.

[26]  Bharat Singh,et al.  Wind Power Interconnection into the Power System: A Review of Grid Code Requirements , 2009 .

[27]  K. Clark,et al.  Frequency responsive wind plant controls: Impacts on grid performance , 2011, 2011 IEEE Power and Energy Society General Meeting.

[28]  Lucy Y. Pao,et al.  Stability analysis of a wind turbine active power control system , 2013, 2013 American Control Conference.

[29]  Jan-Willem van Wingerden,et al.  Field testing a wind turbine drivetrain/tower damper using advanced design and validation techniques , 2013, 2013 American Control Conference.