The BioCAT undulator beamline 18ID: a facility for biological non-crystalline diffraction and X-ray absorption spectroscopy at the Advanced Photon Source.

The 18ID undulator beamline of the Biophysics Collaborative Access Team at the Advanced Photon Source, Argonne, IL, USA, is a high-performance instrument designed for, and dedicated to, the study of partially ordered and disordered biological materials using the techniques of small-angle X-ray scattering, fiber diffraction, and X-ray absorption spectroscopy. The beamline and associated instrumentation are described in detail and examples of the representative experimental results are presented.

[1]  B. Shilton,et al.  Insights into the Conformational Equilibria of Maltose-binding Protein by Analysis of High Affinity Mutants* , 2003, Journal of Biological Chemistry.

[2]  Dmitri I. Svergun,et al.  New developments in direct shape determination from small angle scattering , 1991 .

[3]  D I Svergun,et al.  Restoring low resolution structure of biological macromolecules from solution scattering using simulated annealing. , 1999, Biophysical journal.

[4]  G. Stubbs,et al.  Surface features of potato virus X from fiber diffraction. , 2002, Virology.

[5]  R. Macdonald,et al.  Mixtures of cationic lipid O-ethylphosphatidylcholine with membrane lipids and DNA: phase diagrams. , 2003, Biophysical journal.

[6]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[7]  Sebastian Doniach,et al.  Reconstruction of low-resolution three-dimensional density maps from one-dimensional small-angle X-ray solution scattering data for biomolecules , 2000 .

[8]  Lee Makowski,et al.  High-resolution wide-angle X-ray scattering of protein solutions: effect of beam dose on protein integrity. , 2003, Journal of synchrotron radiation.

[9]  B. Lai,et al.  Nanometer focusing of hard x rays by phase zone plates , 1999 .

[10]  A. Stewart,et al.  The myosin motor in muscle generates a smaller and slower working stroke at higher load , 2004, Nature.

[11]  Robin S. Dothager,et al.  Early collapse is not an obligate step in protein folding. , 2004, Journal of molecular biology.

[12]  C. Catlow,et al.  Synchrotron radiation instrumentation , 1990 .

[13]  T. Irving,et al.  A versatile rapid-mixing and flow device for X-ray absorption spectroscopy. , 2004, Journal of Synchrotron Radiation.

[14]  E Pantos,et al.  Low-resolution structures of proteins in solution retrieved from X-ray scattering with a genetic algorithm. , 1998, Biophysical journal.

[15]  Susan S. Taylor,et al.  Differential effects of substrate on type I and type II PKA holoenzyme dissociation. , 2004, Biochemistry.

[16]  Nick Menhart,et al.  Liquid-chromatography-coupled SAXS for accurate sizing of aggregating proteins. , 2004, Journal of synchrotron radiation.

[17]  Irit Sagi,et al.  Active site electronic structure and dynamics during metalloenzyme catalysis , 2003, Nature Structural Biology.

[18]  D. Koningsberger,et al.  X-ray absorption : principles, applications, techniques of EXAFS, SEXAFS and XANES , 1988 .

[19]  Michael E. Johnson,et al.  Structural Analysis of the αN-Terminal Region of Erythroid and Nonerythroid Spectrins by Small-Angle X-ray Scattering† , 2003 .

[20]  D. Svergun,et al.  CRYSOL : a program to evaluate X-ray solution scattering of biological macromolecules from atomic coordinates , 1995 .

[21]  Susan S. Taylor,et al.  Conformational differences among solution structures of the type Iα, IIα and IIβ protein kinase A regulatory subunit homodimers: Role of the linker regions , 2004 .

[22]  D. Maughan,et al.  In vivo x-ray diffraction of indirect flight muscle from Drosophila melanogaster. , 2000, Biophysical journal.