Care of Patients with Pulmonary Disorders Patient ventilator asynchrony in critically ill adults : Frequency and types

BACKGROUND Patient ventilator asynchrony (PVA) occurs frequently, but little is known about the types and frequency of PVA. Asynchrony is associated with significant patient discomfort, distress and poor clinical outcomes (duration of mechanical ventilation, intensive care unit and hospital stay). METHODS Pressure-time and flow-time waveform data were collected on 27 ICU patients using the Noninvasive Cardiac Output monitor for up to 90 min per subject and blinded waveform analysis was performed. RESULTS PVA occurred during all phases of ventilated breaths and all modes of ventilation. The most common type of PVA was Ineffective Trigger. Ineffective trigger occurs when the patient's own breath effort will not trigger a ventilator breath. The overall frequency of asynchronous breaths in the sample was 23%, however 93% of the sample experienced at least one incident of PVA during their observation period. Seventy-seven percent of subjects experienced multiple types of PVA. CONCLUSIONS PVA occurs frequently in a variety of types although the majority of PVA is ineffective trigger. The study uncovered previously unidentified waveforms that may indicate that there is a greater range of PVAs than previously reported. Newly described PVA, in particular, PVA combined in one breath, may signify substantial patient distress or poor physiological circumstance that clinicians should investigate.

[1]  W. Knaus,et al.  The APACHE III prognostic system. Risk prediction of hospital mortality for critically ill hospitalized adults. , 1991, Chest.

[2]  D. Pierson,et al.  Patient-Ventilator Interaction , 2011, Respiratory Care.

[3]  C. Sessler,et al.  Patient-ventilator dyssynchrony: clinical significance and implications for practice. , 2009, Critical care nurse.

[4]  W. Knaus The APACHE III Prognostic System , 1992 .

[5]  J. Benditt,et al.  Esophageal and gastric pressure measurements. , 2005, Respiratory care.

[6]  Stefano Nava,et al.  Automatic detection of ineffective triggering and double triggering during mechanical ventilation , 2007, Intensive Care Medicine.

[7]  Monitoring of Patient-Ventilator Interaction at the Bedside , 2011 .

[8]  A. Mancini,et al.  Validation of a severity of illness score (APACHE II) in a surgical intensive care unit , 2004, Intensive Care Medicine.

[9]  C S Sassoon,et al.  Patient-ventilator asynchrony , 2001, Current opinion in critical care.

[10]  P. Saldiva,et al.  Volume-assured pressure support ventilation (VAPSV). A new approach for reducing muscle workload during acute respiratory failure. , 1992, Chest.

[11]  J. Leiter,et al.  Effect of inspiratory flow rate on respiratory sensation and pattern of breathing. , 1995, American journal of respiratory and critical care medicine.

[12]  N. MacIntyre,et al.  Combining pressure‐limiting and volume‐cycling features in a patient‐interactive mechanical breath , 1994, Critical care medicine.

[13]  Judith l. Reishtein Sleep in mechanically ventilated patients. , 2005, Critical care nursing clinics of North America.

[14]  A. Modrykamien,et al.  Patterns of Patient-Ventilator Asynchrony as Predictors of Prolonged Mechanical Ventilation , 2012, Anaesthesia and intensive care.

[15]  M. Tobin,et al.  Variability of patient-ventilator interaction with pressure support ventilation in patients with chronic obstructive pulmonary disease. , 1995, American journal of respiratory and critical care medicine.

[16]  François Lellouche,et al.  Patient-ventilator asynchrony during assisted mechanical ventilation , 2006, Intensive Care Medicine.

[17]  C. Sessler,et al.  Protocolized and target-based sedation and analgesia in the ICU. , 2009, Critical care clinics.

[18]  Chris Gennings,et al.  Ineffective triggering predicts increased duration of mechanical ventilation * , 2009, Critical care medicine.

[19]  R. Branson,et al.  Asynchrony and Dyspnea , 2013, Respiratory Care.

[20]  Emilie Bialais,et al.  UNIVERSITE DE LAUSANNE - FACULTE DE BIOLOGIE ET DE MEDECINE Département des centres interdisciplinaires et logistique médicale Service de Médecine intensive adulte et centre des brûlés Neurally Adjusted Ventilatory Assist improves patient-ventilator interaction , 2014 .

[21]  S. Parthasarathy,et al.  Cycling of inspiratory and expiratory muscle groups with the ventilator in airflow limitation. , 1998, American journal of respiratory and critical care medicine.

[22]  Jesse B. Hall,et al.  Impact of Ventilator Adjustment and Sedation–Analgesia Practices on Severe Asynchrony in Patients Ventilated in Assist-Control Mode* , 2013, Critical care medicine.

[23]  C. R. Dick,et al.  Patient-ventilator interactions. , 1996, Clinics in chest medicine.

[24]  C. Bonetto,et al.  Modes of pressure delivery and patient-ventilator interaction. , 2005, Respiratory care clinics of North America.

[25]  R. Dechert,et al.  Patient-determined inspiratory flow during assisted mechanical ventilation , 1995 .

[26]  L. Brochard,et al.  Patient-Ventilator Asynchrony During , 2012 .

[27]  C. Sassoon Triggering of the Ventilator in Patient-Ventilator Interactions , 2011, Respiratory Care.

[28]  Salvatore Grasso,et al.  A method for monitoring and improving patient: ventilator interaction , 2007, Intensive Care Medicine.

[29]  Al M Best,et al.  Observational study of patient-ventilator asynchrony and relationship to sedation level. , 2009, Journal of critical care.

[30]  J. Guttmann,et al.  Total versus tube-related additional work of breathing in ventilator-dependent patients. , 2000, Acta anaesthesiologica Scandinavica.

[31]  M. Tobin,et al.  Use of flow-volume curves in detecting secretions in ventilator-dependent patients. , 1994, American journal of respiratory and critical care medicine.

[32]  S. Epstein How Often Does Patient-Ventilator Asynchrony Occur and What Are the Consequences? , 2011, Respiratory Care.

[33]  M. Plataki,et al.  Patient–ventilator synchrony and sleep quality with proportional assist and pressure support ventilation , 2013, Intensive Care Medicine.

[34]  I Bergbom-Engberg,et al.  Assessment of patients' experience of discomforts during respirator therapy , 1989, Critical care medicine.

[35]  D. Scheinhorn,et al.  Patient-ventilator trigger asynchrony in prolonged mechanical ventilation. , 1997, Chest.

[36]  D. R. Brush,et al.  Sedation and analgesia for the mechanically ventilated patient. , 2009, Clinics in chest medicine.

[37]  Jon O Nilsestuen,et al.  Using ventilator graphics to identify patient-ventilator asynchrony. , 2005, Respiratory care.

[38]  M. Aydoğdu,et al.  [Patient-ventilator interaction]. , 2009, Tuberkuloz ve toraks.

[39]  C. Sessler,et al.  The Richmond Agitation-Sedation Scale: validity and reliability in adult intensive care unit patients. , 2002, American journal of respiratory and critical care medicine.

[40]  Rita Seeger Jablonski,et al.  The Experience of Being Mechanically Ventilated , 1994 .

[41]  E. Kondili,et al.  Bedside waveforms interpretation as a tool to identify patient-ventilator asynchronies , 2005, Intensive Care Medicine.