A novel in situ efficiency estimation algorithm for three-phase induction motors operating with distorted unbalanced voltages

This paper presents a novel algorithm for in situ efficiency estimation for induction motors operating with distorted unbalanced voltages. The proposed technique utilizes the genetic algorithm, IEEE Form F2-Method F1 calculations, large motor test database and a new stray-load loss formula. The technique is evaluated by testing 3 small- and medium-sized induction motors with 11 different combinations of voltage unbalance and total harmonic distortion. The results showed acceptable accuracy. The technique may be used as a potential industrial tool that can help derate induction motors in the presence of voltage unbalance and harmonics distortion.

[1]  Derek A. Paice,et al.  Motor Thermal Protection by Continuous Monitoring of Winding Resistance , 1980, IEEE Transactions on Industrial Electronics and Control Instrumentation.

[2]  W. H. Kersting,et al.  Phase Frame Analysis of the Effects of Voltage Unbalance on Induction Machines , 1996, Proceedings of Rural Electric Power Conference.

[3]  M. Pastorelli,et al.  International standards for the induction motor efficiency evaluation: a critical analysis of the stray-load loss determination , 2003, 38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003..

[4]  P. Pillay,et al.  An In Situ Efficiency Estimation Technique for Induction Machines Working With Unbalanced Supplies , 2012, IEEE Transactions on Energy Conversion.

[5]  Chris Gerada,et al.  Identification of Induction Machine Electrical Parameters Using Genetic Algorithms Optimization , 2008, 2008 IEEE Industry Applications Society Annual Meeting.

[6]  G. H. Rawcliffe,et al.  A simple new test for harmonic-frequency losses in a.c. machines , 1952 .

[7]  Alireza Karimi Ziarani Extraction of nonstationary sinusoids , 2002 .

[8]  C.W. Brice,et al.  Estimation of induction motor parameters by a genetic algorithm , 2003, Conference Record of the 2003 Annual Pulp and Paper Industry Technical Conference, 2003..

[9]  J. Bravo,et al.  Unbalance and harmonics detection in induction motors using an optical fiber sensor , 2006, IEEE Sensors Journal.

[10]  B. N. Gafford,et al.  Heating of Induction Motors on Unbalanced Voltages , 1959, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[11]  Christine M. Anderson-Cook Practical Genetic Algorithms (2nd ed.) , 2005 .

[12]  Percy R. Viego,et al.  Bacterial Foraging Algorithm application for induction motor field efficiency estimation under harmonics and unbalanced voltages , 2013, 2013 International Electric Machines & Drives Conference.

[13]  Pragasen Pillay,et al.  Application of genetic algorithms to motor parameter determination for transient torque calculations , 1997 .

[14]  Francesco Alonge,et al.  Parameter identification of induction motor model using genetic algorithms , 1998 .

[15]  P. Pillay,et al.  Influence of unbalanced voltage on the steady-state performance of a three-phase squirrel-cage induction motor , 2004, IEEE Transactions on Energy Conversion.

[16]  G. C. Jainy The Effect of Voltage Waveshape on the Performance of a 3-Phase Induction Motor , 1964 .

[17]  P. Pillay,et al.  A novel full-load efficiency estimation technique for induction motors operating with unbalanced voltages , 2015, 2015 IEEE International Electric Machines & Drives Conference (IEMDC).

[18]  Y. Wang Analysis of Effects of Three-Phase Voltage Unbalance on Induction Motors with Emphasis on the Angle of the Complex Voltage Unbalance Factor , 2001, IEEE Power Engineering Review.

[19]  Vladimir Sousa,et al.  Estimating induction motor efficiency under no-controlled conditions in the presences of unbalanced and harmonics voltages , 2015, 2015 CHILEAN Conference on Electrical, Electronics Engineering, Information and Communication Technologies (CHILECON).

[20]  Su-Jin Lee,et al.  Equivalent Circuit Considering the Harmonics of Core Loss in the Squirrel-Cage Induction Motor for Electrical Power Steering Application , 2014, IEEE Transactions on Magnetics.

[21]  A. Nagornyy,et al.  Stray load loss efficiency connections , 2004, IEEE Industry Applications Magazine.

[22]  T.G. Habetler,et al.  Non-Intrusive Efficiency Determination of In-Service Induction Motors using Genetic Algorithm and Air-Gap Torque Methods , 2007, 2007 IEEE Industry Applications Annual Meeting.

[23]  Percy R. Viego Felipe,et al.  Procedure for Determining Induction Motor Efficiency Working Under Distorted Grid Voltages , 2015, IEEE Transactions on Energy Conversion.

[24]  K. R. Chakravarthi,et al.  The Effects of Power System Harmonics on Power System Equipment and Loads , 1985, IEEE Transactions on Power Apparatus and Systems.

[25]  P. Pillay,et al.  The use of the genetic algorithm for in-situ efficiency measurement of an induction motor , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[26]  P. Pillay,et al.  California Electricity Situation , 2001, IEEE Power Engineering Review.

[27]  Jyh-Cherng Gu,et al.  Effects of voltage harmonics on the electrical and mechanical performance of a three-phase induction motor , 1998, 1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202).

[28]  Emmanuel B. Agamloh The repeatability of IEEE standard 112B induction motor efficiency tests , 2009, 2009 IEEE International Electric Machines and Drives Conference.

[29]  Haozhong Cheng,et al.  The induction motor parameter estimation through an adaptive genetic algorithm , 2004, 39th International Universities Power Engineering Conference, 2004. UPEC 2004..

[30]  T. Spooner,et al.  Study of Noises in Electrical Apparatus , 1929, Transactions of the American Institute of Electrical Engineers.

[31]  M. Heidari,et al.  Effect of unbalanced voltage on operation of induction motors and its detection , 2009, 2009 International Conference on Electrical and Electronics Engineering - ELECO 2009.

[32]  Pragasen Pillay,et al.  A Novel In Situ Efficiency Estimation Algorithm for Three-Phase IM Using GA, IEEE Method F1 Calculations, and Pretested Motor Data , 2015, IEEE Transactions on Energy Conversion.

[33]  T.G. Habetler,et al.  An on-line stator winding resistance estimation technique for temperature monitoring of line-connected induction machines , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[34]  Pragasen Pillay,et al.  In-situ induction motor efficiency determination using the genetic algorithm , 1998 .

[35]  Wenping Cao,et al.  Comparison of Stray Load and Inverter-Induced Harmonic Losses in Induction Motors Using Calorimetric and Harmonic Injection Methods , 2010 .

[36]  Pragasen Pillay,et al.  A Novel In Situ Efficiency Estimation Algorithm for Three-Phase Induction Motors Operating With Distorted Unbalanced Voltages , 2016, IEEE Transactions on Industry Applications.

[37]  Pragasen Pillay,et al.  A Novel Technique for In Situ Efficiency Estimation of Three-Phase IM Operating With Unbalanced Voltages , 2016, IEEE Transactions on Industry Applications.

[38]  R. R. Bishop,et al.  Identifying induction machine parameters using a genetic optimization algorithm , 1990, IEEE Proceedings on Southeastcon.

[39]  Pragasen Pillay,et al.  A Novel Algorithm for Estimating Refurbished Three-Phase Induction Motors Efficiency Using Only No-Load Tests , 2015, IEEE Transactions on Energy Conversion.

[40]  Pragasen Pillay,et al.  A New Stray-Load Loss Formula for Small and Medium-Sized Induction Motors , 2016, IEEE Transactions on Energy Conversion.

[41]  Enrique C. Quispe,et al.  Effects of unbalanced voltages on the energy performance of three-phase induction motors , 2015, 2015 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA).