Use of an ultrahigh-speed laser scanner for constructing three-dimensional shapes of dentition and occlusion.

STATEMENT OF PROBLEM Acquisition of the 3-dimensional shape of dental casts is useful for quantitative evaluation of the diagnosis and treatment of occlusion. PURPOSE This study demonstrated the acquisition of data through the use of an ultrahigh-speed laser scanner and an originally developed goniometer, the use of these tools to measure the entire 3-dimensional shape of the dental cast from multiple directions, and the connection of the data measurements to reconstruct the cast's occlusion with the use of a computer. MATERIAL AND METHODS A commercially available apparatus that emits a line laser and completes 1 scan in only 0.6 seconds was used. To compensate for the unmeasured region, the cast was measured from 4 directions on the original goniometer, and the connection of data to obtain the entire image was carried out. Further, the reconstruction of the occlusion between the upper and lower casts was attempted by transferring the upper cast data to the lower cast. RESULTS By the data connection, the entire shape of the upper and lower casts was constructed, and the characteristic structure was reproduced. The data connections were satisfactory for the flat surfaces but less accurate for the inclined surfaces. Reconstruction of the occlusion between the upper and lower casts was accomplished. It was then possible to visualize the occlusion from arbitrary directions and sections with computer graphics. CONCLUSION The construction of the entire 3-dimensional shape of a dental cast and the reconstruction of the occlusion were accomplished using an ultrahigh-speed measurement system and original goniometer. These results will be useful for clinical applications such as computerized diagnoses and treatment of occlusion, and for the replacement of the stone casts in the dental office by computerized data.

[1]  T Mikami,et al.  Optical measurement of dental cast profile and application to analysis of three-dimensional tooth movement in orthodontics. , 1989, Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering.

[2]  Harold D. Kesling,et al.  The diagnostic setup with consideration of the third dimension , 1956 .

[3]  Taiji Sohmura,et al.  Construction of 3-D Shape of Orthodontic Dental Casts Measured from Two Directions , 1998 .

[4]  R Hickel,et al.  A New Optical 3-D Device for the Detection of Wear , 1997, Journal of dental research.

[5]  T Sohmura,et al.  Development of the computerized dental cast form analyzing system--three dimensional diagnosis of dental arch form and the investigation of measuring condition. , 1997, Dental materials journal.

[6]  W H Mörmann,et al.  The new creativity in ceramic restorations: dental CAD-CIM. , 1996, Quintessence international.

[7]  T Kuroda,et al.  Three-dimensional dental cast analyzing system using laser scanning. , 1996, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[8]  F.C.A. Groen,et al.  Image processing on personal computers , 1989, IEEE 1989 International Conference on Systems Engineering.

[9]  H Boersma,et al.  Three-Dimensional Analysis of Dental Casts by Means of the Optocom , 1972, Journal of dental research.

[10]  T Kuroda,et al.  [High accuracy measuring device for dental cast--using device with flat laser beam]. , 1992, Kokubyo Gakkai zasshi. The Journal of the Stomatological Society, Japan.