Catheter Ultrasound Phased-Array Transducers for Thermal Ablation: A Feasibility Study

The feasibility of catheter single-element ultrasound transducers for cardiac ablation has been shown previously. We describe the design and testing of catheter-sized linear phased arrays transducers for ultrasound ablation. One array has 86 PZT-4 elements operating at 8 MHz and 5 MHz. The overall array size is 14.9 mm by 3.1 mm (10 Fr). The other array has 50 PZT-5 elements operating at 4 MHz and is 17 mm by 3.1 mm (10 Fr). In order to produce the intensity needed to create lesions in heart tissue, we modified a real-time, 3D scanner to produce 100 Vpp 256-cycle transmit pulses at a pulse repetition frequency of 14.1 kHz. This made it possible for the PZT-4 and PZT-5 transducers to produce ISPTA of 3.26 W/cm2 and 142 W/cm2, respectively. When driving the transducers at high duty factor, the transmit circuitry in the scanner was damaged. A mechanically-focused transducer with the same dimensions as the PZT-4 transducer was built. When transmitting continuously at 9 MHz, it produced an ISPTA of 29.3 W/cm2. This created a lesion 5 mm across and 5 mm deep in beef tissue while raising the focal temperature 23°C. Ablation is within the capabilities of a catheter phased array transducer integrated into a diagnostic ultrasound scanner.

[1]  Stephen B. Solomon,et al.  Initial Experience with a Novel Focused Ultrasound Ablation System for Ring Ablation Outside the Pulmonary Vein , 2003, Journal of Interventional Cardiac Electrophysiology.

[2]  J. Olgin,et al.  Electrophysiological effects of long, linear atrial lesions placed under intracardiac ultrasound guidance. , 1997, Circulation.

[3]  W. Dewey,et al.  Thermal dose determination in cancer therapy. , 1984, International journal of radiation oncology, biology, physics.

[4]  Xiaobing Fan,et al.  Evaluation of accuracy of a theoretical model for predicting the necrosed tissue volume during focused ultrasound surgery , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  Stephen W. Smith,et al.  Combined 3D intracardiac echo and ultrasound ablation , 2003, SPIE Medical Imaging.

[6]  R. Krimholtz,et al.  New equivalent circuits for elementary piezoelectric transducers , 1970 .

[7]  William H. Nau,et al.  Novel Catheter Technology for Ablative Cure of Atrial Fibrillation , 2004, Journal of Interventional Cardiac Electrophysiology.

[8]  D. Haines,et al.  Ablation for the treatment of arrhythmias , 1996, Proc. IEEE.

[9]  F. Marcus,et al.  The feasibility of using ultrasound for cardiac ablation , 1993, IEEE Transactions on Biomedical Engineering.

[10]  S.W. Smith,et al.  High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  S.W. Smith,et al.  Integrated catheter for 3-d intracardiac echo cardiography and ultrasound ablation , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  Patrick D Wolf,et al.  Dual lumen transducer probes for real-time 3-D interventional cardiac ultrasound. , 2003, Ultrasound in medicine & biology.

[14]  S.W. Smith,et al.  High-speed ultrasound volumetric imaging system. II. Parallel processing and image display , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.