A high-frequency continuous-wave Doppler ultrasound system for the detection of blood flow in the microcirculation.

Basic ultrasound physics and several clinical and experimental observations suggest that high-frequency Doppler ultrasound (HFD) operating in the frequency range 20-100 MHz holds the promise of detecting blood flow in the microcirculation. This article describes a directional, continuous-wave (CW), 1- to 200-MHz Doppler ultrasound system. The system electronics have a dynamic range of 100 dB, a noise floor of 10 nV and a directional isolation of 50 dB. The development of a 40-MHz Doppler transducer composed of two, 81-micron-thick, lithium niobate crystals that have been air-backed and transmission-line tuned for maximum sensitivity is described. This device is used to test the CW Doppler system using string and capillary phantoms and in vivo tissue. We show that HFD can detect and measure velocities on the order of the blood velocities found in the capillaries (1 mm/s) and arterioles (5 mm/s) with suitable velocity (50-500 microns/s) and temporal (20-250 ms) resolutions. In vivo measurements demonstrate that HFD is sensitive to the detection of blood flow in small vessels.

[1]  F Patat,et al.  Very high frequency pulsed Doppler apparatus. , 1989, Ultrasound in medicine & biology.

[2]  D. A. Christopher,et al.  A high-frequency pulsed-wave Doppler ultrasound system for the detection and imaging of blood flow in the microcirculation. , 1997, Ultrasound in medicine & biology.

[3]  K Lindström,et al.  Blood perfusion measurement with multifrequency Doppler ultrasound. , 1995, Ultrasound in medicine & biology.

[4]  M. Reid,et al.  Design for an ultrasound-based instrument for measurement of tissue blood flow. , 1989, Biomaterials, artificial cells, and artificial organs.

[5]  J. Woodcock,et al.  Doppler ultrasound and its use in clinical measurement , 1983 .

[6]  R. Giblin,et al.  The choice of ultrasound frequency for skin blood flow investigation , 1985 .

[7]  P. Payne,et al.  Measurement of properties and function of skin. , 1991, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[8]  F. S. Foster,et al.  Ultrasound Biomicroscopy of the Eye , 1994, Springer New York.

[9]  L From,et al.  A 40-100 MHz B-scan ultrasound backscatter microscope for skin imaging. , 1995, Ultrasound in medicine & biology.

[10]  Peter N. Burns,et al.  Harmonic power mode Doppler using microbubble contrast agents: an improved method for small vessel flow imaging , 1994, 1994 Proceedings of IEEE Ultrasonics Symposium.

[11]  J M Rubin,et al.  Power Doppler US: a potentially useful alternative to mean frequency-based color Doppler US. , 1994, Radiology.

[12]  V. Newhouse,et al.  Doppler ultrasound technique for measuring capillary-speed flow velocities with strong stationary echoes. , 1992, Ultrasonics.

[13]  P. Carson,et al.  Ultrasonic estimation of tissue perfusion: a stochastic approach. , 1995, Ultrasound in medicine & biology.

[14]  F. Foster,et al.  Fabrication of high frequency spherically shaped ceramic transducers , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  H. Goldsmith,et al.  Rheological Aspects of Thrombosis and Haemostasis: Basic Principles and Applications , 1986, Thrombosis and Haemostasis.

[16]  J W Hunt,et al.  The effect of refraction and assumed speeds of sound in tissue and blood on Doppler ultrasound blood velocity measurements. , 1995, Ultrasound in medicine & biology.

[17]  T. Loupas,et al.  Experimental evaluation of velocity and power estimation for ultrasound blood flow imaging, by means of a two-dimensional autocorrelation approach , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  F. Foster,et al.  Principles and applications of ultrasound backscatter microscopy , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  S. Dymling,et al.  Measurement of blood perfusion in tissue using Doppler ultrasound. , 1991, Ultrasound in medicine & biology.

[20]  G. R. Lockwood,et al.  Ultrasound backscatter from blood in the 30 to 70 MHz frequency range , 1994, 1994 Proceedings of IEEE Ultrasonics Symposium.

[21]  F Forsberg,et al.  Ultrasound contrast agents: a review. , 1994, Ultrasound in medicine & biology.

[22]  V L Newhouse,et al.  Second harmonic ultrasonic blood perfusion measurement. , 1993, Ultrasound in medicine & biology.