Peripapillary nerve fiber layer thickness profile determined with high speed, ultrahigh resolution optical coherence tomography high-density scanning.

PURPOSE To determine the retinal nerve fiber layer (RNFL) thickness profile in the peripapillary region of healthy eyes. METHODS Three-dimensional, Fourier/spectral domain optical coherence tomography (OCT) data were obtained as raster scan data (512 x 180 axial scans in a 6 x 6-mm region centered on the optic nerve head [ONH]) with high-speed, ultrahigh-resolution OCT (hsUHR-OCT) from 12 healthy subjects. RNFL thickness was measured on this three-dimensional data set with an in-house software program. The disc margin was defined subjectively in each image and RNFL thickness profiles relative to distance from the disc center were computed for quadrants and clock hours. A mixed-effects model was used to characterize the slope of the profiles. RESULTS Thickness profiles in the superior, inferior, and temporal quadrants showed an initial increase in RNFL thickness, an area of peak thickness, and a linear decrease as radial distance from the disc center increased. The nasal quadrant showed a constant linear decay without the initial RNFL thickening. A mixed-effects model showed that the slopes of the inferior, superior, and nasal quadrants differed significantly from the temporal slope (P = 0.0012, P = 0.0003, and P = 0.0004, respectively). CONCLUSIONS RNFL thickness is generally inversely related to the distance from the ONH center in the peripapillary region of healthy subjects, as determined by hsUHR-OCT. However, several areas showed an initial increase in RNFL, followed by a peak and a gradual decrease.

[1]  J. Fujimoto,et al.  High Speed, Ultrahigh Resolution Retinal Imaging using Spectral/Fourier Domain OCT , 2005, 2005 Pacific Rim Conference on Lasers & Electro-Optics.

[2]  P. Carpineto,et al.  Reliability of nerve fiber layer thickness measurements using optical coherence tomography in normal and glaucomatous eyes. , 2003, Ophthalmology.

[3]  D. Bates,et al.  Mixed-Effects Models in S and S-PLUS , 2001 .

[4]  Changhuei Yang,et al.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography. , 2003, Optics express.

[5]  R Varma,et al.  Retinal nerve fibre layer thickness profile in normal eyes using third-generation optical coherence tomography , 2006, Eye.

[6]  P J Airaksinen,et al.  Diffuse and localized nerve fiber loss in glaucoma. , 1984, American journal of ophthalmology.

[7]  A. Sommer,et al.  Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss. , 1991, Archives of ophthalmology.

[8]  Ömer Faruk Yilmaz,et al.  Influence of Scan Radius Correction for Ocular Magnification and Relationship Between Scan Radius With Retinal Nerve Fiber Layer Thickness Measured by Optical Coherence Tomography , 2001, Journal of glaucoma.

[9]  Teresa C. Chen,et al.  Retinal nerve fiber layer thickness map determined from optical coherence tomography images. , 2005, Optics express.

[10]  L. Zangwill,et al.  Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes. , 1995, American journal of ophthalmology.

[11]  H. Quigley,et al.  Clinical evaluation of nerve fiber layer atrophy as an indicator of glaucomatous optic nerve damage. , 1980, Archives of ophthalmology.

[12]  R. Radius Thickness of the retinal nerve fiber layer in primate eyes. , 1980, Archives of ophthalmology.

[13]  J. Fujimoto,et al.  Optical coherence tomography of the human retina. , 1995, Archives of ophthalmology.

[14]  R. Knighton,et al.  Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes. , 2005, Investigative ophthalmology & visual science.

[15]  B. Bouma,et al.  Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. , 2003, Optics letters.

[16]  M A Mainster,et al.  Scanning Laser Ophthalmoscopy: Clinical Applications , 1982 .

[17]  J. Jonas,et al.  Retinal nerve fiber layer thickness in human eyes , 1999, Graefe's Archive for Clinical and Experimental Ophthalmology.

[18]  A. Fercher,et al.  Performance of fourier domain vs. time domain optical coherence tomography. , 2003, Optics express.

[19]  J. Duker,et al.  Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation. , 2004, Optics express.

[20]  J. Fujimoto,et al.  Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography. , 1996, Ophthalmology.

[21]  G. Wollstein,et al.  Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT. , 2004, Investigative ophthalmology & visual science.

[22]  L Frisén,et al.  Fundoscopy of nerve fiber layer defects in glaucoma. , 1973, Investigative ophthalmology.

[23]  R Varma,et al.  Retinal nerve fiber layer thickness in normal human eyes. , 1996, Ophthalmology.

[24]  J. Duker,et al.  Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography. , 2005, Ophthalmology.

[25]  Teresa C. Chen,et al.  In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography. , 2004, Optics letters.

[26]  D. R. Anderson,et al.  The course of axons through the retina and optic nerve head. , 1979, Archives of ophthalmology.