Analytical g-function for inclined boreholes in ground-source heat pump systems

In the design of ground-source heat pump systems, the calculation of the total length of the bore field is very important because it is responsible for the major part of the initial cost. Some technologies, like direct expansion systems and pile systems, often use inclined boreholes. Most design methods do not consider this effect and may overestimate the total length needed for a typical application. This paper gives a method for the calculation of time response factors in a form called g-function for inclined boreholes. The analytical model can be used in a parameterized optimization algorithm to design an optimum bore field. The method is a generalization of a method previously proposed for vertical boreholes. Comparison of the new g-function with tabulated values found in the literature is given, and an application for a typical design is presented as an example.

[1]  Hongxing Yang,et al.  Heat transfer analysis of ground heat exchangers with inclined boreholes , 2006 .

[2]  Richard Labib,et al.  A Multiple Load Aggregation Algorithm for Annual Hourly Simulations of GCHP Systems , 2004 .

[3]  Per Eskilson Thermal analysis of heat extraction boreholes , 1987 .

[4]  Dominique Marchio,et al.  Sizing Calculation Spreadsheet Vertical Geothermal Borefields , 2010 .

[5]  Tatyana V. Bandos,et al.  Finite line-source model for borehole heat exchangers: effect of vertical temperature variations , 2009 .

[6]  W. Gander,et al.  Adaptive Quadrature—Revisited , 2000 .

[7]  Philippe Pasquier,et al.  Fast fluid and ground temperature computation for geothermal ground-loop heat exchanger systems , 2008 .

[8]  Z. Fang,et al.  A finite line‐source model for boreholes in geothermal heat exchangers , 2002 .

[9]  Philippe Pasquier,et al.  The effect of borehole inclination on fluid and ground temperature for GLHE systems , 2009 .

[10]  Simon Chapuis,et al.  Stockage thermique saisonnier dans un champ de puits géothermiques verticaux en boucle fermée. , 2009 .

[11]  Daniel Pahud,et al.  Heat Storage in the Ground. Duct Ground Heat Storage Model for TRNSYS (TRNVDST). User Manual for the October 1996 Version , 1996 .

[12]  Jeffrey D. Spitler,et al.  A short time step response factor model for vertical ground loop heat exchangers , 1999 .

[13]  Stanislaw Kajl,et al.  A review of methods to evaluate borehole thermal resistances in geothermal heat-pump systems , 2010 .

[14]  J. C. Jaeger,et al.  Conduction of Heat in Solids , 1952 .

[15]  Louis Lamarche,et al.  A fast algorithm for the hourly simulations of ground-source heat pumps using arbitrary response factors , 2009 .

[16]  M. Bernier,et al.  Validity ranges of three analytical solutions to heat transfer in the vicinity of single boreholes , 2009 .

[17]  Louis Lamarche,et al.  A new contribution to the finite line-source model for geothermal boreholes , 2007 .