Rapid electrochemical detection and identification of catalase positive micro-organisms.

The rapid detection and identification of bacteria has application in a number of fields, e.g. the food industry, environmental monitoring and biomedicine. While in biomedicine the number of organisms present during infection is multiples of millions in the other fields it is the detection of low numbers of organisms that is important, e.g. an infective dose of Escherichia coli O157:H7 from contaminated food is less than 100 organisms. A rapid and sensitive technique has been developed to detect low numbers of the model organism E. coli O55, combining Lateral Flow Immunoassay (LFI) for capture and amperometry for sensitive detection. Nitrocellulose membranes were used as the solid phase for selective capture of the bacteria using antibodies to E. coli O55. Different concentrations of E. coli O55 in Ringers solution were applied to LFI strips and allowed to flow through the membrane to an absorbent pad. The capture region of the LFI strip was placed in close contact with the electrodes of a Clarke cell poised at +0.7 V for the detection of hydrogen peroxide. Earlier research identified that the consumption of hydrogen peroxide by bacterial catalase provided a sensitive indicator of aerobic and facultative anaerobic microorganisms numbers. Modification and application of this technique to the LFI strips demonstrated that the consumption of 8 mM hydrogen peroxide was correlated with the number of microorganisms presented to the LFI strips in the range of 2 x 10(1)-2 x 10(7) colony forming units (cfu). Capture efficiency was dependent on the number of organisms applied and varied from 71% at 2 x 10(2) cfu to 25% at 2 x 10(7) cfu. The procedure was completed in less than 10 min and could detect less than 10 cfu captured from a 200 microl sample applied to the LFI strip. The approached adopted provides proof of principle for the basis of a new technological approach to the rapid, quantitative and sensitive detection of bacteria that express catalase activity.

[1]  Ihab Abdel-Hamid,et al.  Highly sensitive flow-injection immunoassay system for rapid detection of bacteria , 1999 .

[2]  P Atanasov,et al.  Flow-through immunofiltration assay system for rapid detection of E. coli O157:H7. , 1999, Biosensors & bioelectronics.

[3]  I. Jones,et al.  An outbreak of Escherichia coli O157 and campylobacteriosis associated with contamination of a drinking water supply. , 1996, Public health.

[4]  B. Hock,et al.  Advances in immunochemical detection of microorganisms. , 1996, Annales de biologie clinique.

[5]  Dmitri Ivnitski,et al.  Biosensors for detection of pathogenic bacteria , 1999 .

[6]  A. Egorov,et al.  Chemiluminescent immunoenzyme biosensor with a thin-layer flow-through cell. Application for study of a real-time bimolecular antigen-antibody interaction. , 1996, Biosensors & bioelectronics.

[7]  P. Choudary,et al.  Detection of Escherichia coli O157:H7 in ground beef in eight hours , 1998 .

[8]  R. Soltis,et al.  The effect of serum immunoglobulin concentration on immune complex detection by polyethylene glycol. , 1983, Journal of immunological methods.

[9]  A. Gehring,et al.  Immunoelectrochemical assays for bacteria: use of epifluorescence microscopy and rapid-scan electrochemical techniques in development of an assay for Salmonella. , 1996, Analytical chemistry.

[10]  P. Feng,et al.  Emergence of rapid methods for identifying microbial pathogens in foods. , 1996, Journal of AOAC International.

[11]  Ş. Kayalı,et al.  Enterohemorrhagic Escherichia coli. A dangerous food-borne pathogen. , 1998, Postgraduate medicine.

[12]  R. Salmon,et al.  Vero cytotoxin‐producing Escherichia coli O157 in beefburgers linked to an outbreak of diarrhoea, haemorrhagic colitis and haemolytic uraemic syndrome in Britain , 1994, Letters in applied microbiology.

[13]  R. van Eijk,et al.  Optimizing the solid-phase immunofiltration assay. A rapid alternative to immunoassays. , 1989, Journal of immunological methods.

[14]  David W. K. Acheson,et al.  Shiga toxin-producing Escherichia coli , 2000, Current infectious disease reports.

[15]  B T Butman,et al.  Detection of Escherichia coli O157:H7 in meat by an enzyme-linked immunosorbent assay, EHEC-Tek , 1995, Applied and environmental microbiology.

[16]  A P Turner,et al.  Immunomagnetic separation with mediated flow injection analysis amperometric detection of viable Escherichia coli O157. , 1998, Analytical chemistry.

[17]  J. Brewster,et al.  Filtration capture and immunoelectrochemical detection for rapid assay of Escherichia coli O157:H7. , 1998, Journal of immunological methods.

[18]  C. Park,et al.  Rapid Immunoassay for detection of Escherichia coli O157 directly from stool specimens , 1996, Journal of clinical microbiology.

[19]  J. Brewster,et al.  Filtration capture immunoassay for bacteria: optimization and potential for urinalysis. , 1999, Journal of microbiological methods.

[20]  A. Heuvelink,et al.  Methods for the detection and isolation of Shiga toxin‐producing Escherichia coli , 2000, Symposium series.

[21]  J H Luong,et al.  Development of a flow injection analysis (FIA) immunosensor for the detection of Escherichia coli. , 1995, International journal of food microbiology.

[22]  R. Tauxe,et al.  The epidemiology of infections caused by Escherichia coli O157:H7, other enterohemorrhagic E. coli, and the associated hemolytic uremic syndrome. , 1991, Epidemiologic reviews.

[23]  J. Coia,et al.  Clinical, microbiological and epidemiological aspects of Escherichia coli O157 infection , 2006 .

[24]  P Atanasov,et al.  Immunosensors: electrochemical sensing and other engineering approaches. , 1998, Biosensors & bioelectronics.

[25]  H. Karch,et al.  Epidemiology and diagnosis of Shiga toxin-producing Escherichia coli infections. , 1999, Diagnostic microbiology and infectious disease.

[26]  J. Coia,et al.  Clinical, microbiological and epidemiological aspects of Escherichia coli O157 infection. , 1998, FEMS immunology and medical microbiology.

[27]  C. Collins,et al.  Collins and Lyne's microbiological methods , 1984 .

[28]  C W Blackburn,et al.  Modifications to methods for the enumeration and detection of injured Escherichia coli O157:H7 in foods. , 2000, International journal of food microbiology.

[29]  Near patient microbiological tests , 1999, BMJ.