Micro-receiver guided transcranial beam steering

A new method for focusing ultrasound energy in brain tissue through the skull is investigated. The procedure is designed for use with a therapeutic transducer array and a small catheter-inserted hydrophone receiver placed in the brain to guide the array's focus. When performed at high-intensity, a focal intensity on the order of several hundred watts per centimeter-squared is achieved, and cells within a target volume are destroyed. The present study tests the feasibility and range of the method using an ex vivo human skull. Acoustic phase information is obtained from the stationary receiver and used to electrically shift the beam to new locations as well as correct for aberrations due to the skull. The method is applied to a 104-element 1.1 MHz array and a 120-element 0.81 MHz array. Using these array configurations, it is determined that the method can reconstruct and steer a focus over a distance of 50 mm. Application of this minimally invasive technique for ultrasound brain therapy and surgery also is investigated in vitro with a 64-element 0.664 MHz hemisphere array designed for transskull surgery. Tissue is placed inside of a skull and a catheter-inserted receiver is inserted into the tissue. A focus intense enough to coagulate the tissue is achieved at a predetermined location 10 mm from the receiver, the maximum distance that this large element array can electronically steer the focus.

[1]  M. Fink Time reversed acoustics , 2001 .

[2]  J. L. Thomas,et al.  Focusing and steering through absorbing and aberrating layers: application to ultrasonic propagation through the skull. , 1998, The Journal of the Acoustical Society of America.

[3]  Gregory T. Clement,et al.  A hemisphere array for non-invasive ultrasound brain therapy and surgery. , 2000, Physics in medicine and biology.

[4]  K. Hynynen,et al.  Evaluation of the combined concentric-ring sector-vortex phased array for MR-guided ultrasound surgery , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[5]  K. Hynynen,et al.  Design and evaluation of a feedback based phased array system for ultrasound surgery , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  Gregory T. Clement,et al.  Investigation of a large-area phased array for focused ultrasound surgery through the skull. , 2000, Physics in medicine and biology.

[7]  Kim C. Benjamin,et al.  Forward and backward projection of acoustic fields using FFT methods , 1981 .

[8]  R C Waag,et al.  Correction of ultrasonic wavefront distortion using backpropagation and a reference waveform method for time-shift compensation. , 1994, The Journal of the Acoustical Society of America.

[9]  F. Fry,et al.  Further studies of the transkull transmission of an intense focused ultrasonic beam: lesion production at 500 kHz. , 1980, Ultrasound in medicine & biology.

[10]  P. VanBaren,et al.  A hybrid computational model for ultrasound phased-array heating in presence of strongly scattering obstacles , 1997, IEEE Transactions on Biomedical Engineering.

[11]  F A Jolesz,et al.  Demonstration of potential noninvasive ultrasound brain therapy through an intact skull. , 1998, Ultrasound in medicine & biology.

[12]  M O'Donnell,et al.  Phase Aberration Measurements in Medical Ultrasound: Human Studies , 1988, Ultrasonic imaging.

[13]  G E Trahey,et al.  Phased array ultrasound imaging through planar tissue layers. , 1986, Ultrasound in medicine & biology.

[14]  P. VanBaren,et al.  Noninvasive real-time multipoint temperature control for ultrasound phased array treatments , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  J L Thomas,et al.  Time reversal and the inverse filter. , 2000, The Journal of the Acoustical Society of America.

[16]  F. Fry,et al.  Transkull transmission of an intense focused ultrasonic beam. , 1977, Ultrasound in medicine & biology.

[17]  F. Fry,et al.  Transkull focal lesions in cat brain produced by ultrasound. , 1981, Journal of neurosurgery.

[18]  P. VanBaren,et al.  Dynamic focusing in ultrasound hyperthermia treatments using implantable hydrophone arrays , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  Clement,et al.  Field characterization of therapeutic ultrasound phased arrays through forward and backward planar projection , 2000, The Journal of the Acoustical Society of America.