Over/Undervoltage and Undervoltage Shift of Hybrid Islanding Detection Method of Distributed Generation

The mainly used local islanding detection methods may be classified as active and passive methods. Passive methods do not perturb the system but they have larger nondetection zones, whereas active methods have smaller nondetection zones but they perturb the system. In this paper, a new hybrid method is proposed to solve this problem. An over/undervoltage (passive method) has been used to initiate an undervoltage shift (active method), which changes the undervoltage shift of inverter, when the passive method cannot have a clear discrimination between islanding and other events in the system. Simulation results on MATLAB/SIMULINK show that over/undervoltage and undervoltage shifts of hybrid islanding detection method are very effective because they can determine anti-islanding condition very fast. ΔP/P > 38.41% could determine anti-islanding condition within 0.04 s; ΔP/P < −24.39% could determine anti-islanding condition within 0.04 s; −24.39% ≤ ΔP/P ≤ 38.41% could determine anti-islanding condition within 0.08 s. This method perturbed the system, only in the case of −24.39% ≤ ΔP/P ≤ 38.41% at which the control system of inverter injected a signal of undervoltage shift as necessary to check if the occurrence condition was an islanding condition or not.

[1]  Nadejda Komendantova,et al.  Renewables 2012 Global Status Report , 2012 .

[2]  Stephen J. Finney,et al.  Harmonic distortion-based island detection technique for inverter-based distributed generation , 2009 .

[3]  Ren Renewables 2019 Global Status Report , 2012 .

[4]  Fei Wang,et al.  Power Equations and Non-Detection Zone of Passive Islanding Detection and Protection Method for Grid Connected Photovoltaic Generation System , 2009, 2009 Pacific-Asia Conference on Circuits, Communications and Systems.

[5]  Heejun Kim,et al.  An improved method for anti-islanding by reactive power control , 2005, 2005 International Conference on Electrical Machines and Systems.

[6]  Suttichai Premrudeepreechacharn,et al.  Investigation of Relationship between Voltage and Nondetection Zone of OUV/OUF of Local Islanding Detection Techniques , 2014 .

[7]  Yu Zhang,et al.  Evaluation of anti-islanding schemes based on nondetection zone concept , 2004, IEEE Transactions on Power Electronics.

[8]  S. Premrudeepreechacharn,et al.  Investigation over/under-voltage protection of passive islanding detection method of distributed generations in electrical distribution systems , 2012, 2012 International Conference on Renewable Energy Research and Applications (ICRERA).

[9]  S. Munk-Nielsen,et al.  A new passive islanding detection method for grid-connected PV inverters , 2008, 2008 International Symposium on Power Electronics, Electrical Drives, Automation and Motion.

[10]  Emilio Figueres,et al.  Review of anti-islanding techniques in distributed generators , 2010 .

[11]  Mikihiko Matsui,et al.  A review of current anti-islanding methods for photovoltaic power system , 2010 .

[12]  Zhe Chen,et al.  Review of islanding detection methods for distributed generation , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.