Measurement and correction of stimulated echo contamination in T2-based iron quantification.

[1]  Daniel Kim,et al.  Rapid monitoring of iron‐chelating therapy in thalassemia major by a new cardiovascular MR measure: the reduced transverse relaxation rate , 2011, NMR in biomedicine.

[2]  Daniel Kim,et al.  Reduced transverse relaxation rate (RR2) for improved sensitivity in monitoring myocardial iron in thalassemia , 2011, Journal of magnetic resonance imaging : JMRI.

[3]  Haiying Tang,et al.  Magnetic resonance assessment of iron overload by separate measurement of tissue ferritin and hemosiderin iron , 2010, Annals of the New York Academy of Sciences.

[4]  Srirama V Swaminathan,et al.  Separate MRI quantification of dispersed (ferritin‐like) and aggregated (hemosiderin‐like) storage iron , 2010, Magnetic resonance in medicine.

[5]  D. Pennell,et al.  Development of a novel optimized breathhold technique for myocardial T2 measurement in thalassemia , 2006, Journal of magnetic resonance imaging : JMRI.

[6]  Gaby S Pell,et al.  Optimized clinical T2 relaxometry with a standard CPMG sequence , 2006, Journal of magnetic resonance imaging : JMRI.

[7]  T. Brown,et al.  Methods for Noninvasive Measurement of Tissue Iron in Cooley's Anemia , 2005, Annals of the New York Academy of Sciences.

[8]  T. S. St. Pierre,et al.  Single spin‐echo proton transverse relaxometry of iron‐loaded liver , 2004, NMR in biomedicine.

[9]  P. Jensen Evaluation of iron overload , 2004, British journal of haematology.

[10]  G. Brittenham,et al.  Noninvasive measurement of iron: report of an NIDDK workshop. , 2003, Blood.

[11]  R. Chandra,et al.  Theory of nonexponential NMR signal decay in liver with iron overload or superparamagnetic iron oxide particles , 2002, Magnetic resonance in medicine.

[12]  J. Bulte,et al.  T1 and T2 of ferritin solutions: Effect of loading factor , 1996, Magnetic resonance in medicine.

[13]  P. R. Moran,et al.  Magnetization transfer or spin-lock? An investigation of off-resonance saturation pulse imaging with varying frequency offsets. , 1996, AJNR. American journal of neuroradiology.

[14]  T W Redpath,et al.  The influence of stimulated echoes on contrast in fast spin-echo imaging. , 1996, Magnetic resonance imaging.

[15]  William H. Press,et al.  The Art of Scientific Computing Second Edition , 1998 .

[16]  C. S. Poon,et al.  Practical T2 quantitation for clinical applications , 1992, Journal of magnetic resonance imaging : JMRI.

[17]  F. A. Seiler,et al.  Numerical Recipes in C: The Art of Scientific Computing , 1989 .