Increasing the accuracy of orbital reconstruction with selective laser-melted patient-specific implants combined with intraoperative navigation.

PURPOSE Advances in technology have allowed increasing degrees of accuracy in the treatment of orbital deformities. The purpose of this study was to compare the accuracy of pre-bent titanium mesh (PBTM) and selective laser-melted patient-specific implants (PSIs) in unilateral orbital reconstruction after traumatic injury. The authors hypothesized that selective laser-melted PSIs would more accurately reconstruct the orbit. MATERIALS AND METHODS A retrospective review of 34 cases of primary reconstruction of unilateral orbital fractures treated using selective laser-melted PSIs (group 1, n = 17) or PBTM (group 2, n = 17) was performed. The primary outcome measurements were orbital volume excess and the anterior, medial, and posterior intraorbital angles. The Mann-Whitney U test was used to assess the difference in orbital volume and angular deviation between the 2 groups. The level of statistical significance was set at .05. All P values were 2-sided. RESULTS The comparison of mean values for the 2 groups showed significant differences for the anterior angle (PBTM: mean, 11.3; standard deviation [SD], 1.8; PSI: mean, 4.1; SD, 0.7; P = .001), but not the medial (PBTM: mean, 11.6; SD, 2.0; PSI: mean, 8.2; SD, 1.9; P = .170) and posterior (PBTM: mean, 10.8, SD, 2.8; PSI: mean, 8.2, SD, 1.4; P = .760) angles between the unaffected and reconstructed orbits. The postoperative difference in volume between the unaffected and reconstructed orbits differed significantly between the 2 study groups (PBTM: mean, 0.6; SD, 0.1; PSI: mean, 0.4; SD, 0.1; P = .029). CONCLUSION The results of this study suggest that complex orbital fractures can be reconstructed with an even higher degree of accuracy with selective laser-melted PSIs than with PBTM.

[1]  G. Brunelli,et al.  Orbital fractures: a new classification and staging of 190 patients. , 2006, The Journal of craniofacial surgery.

[2]  P L Evans,et al.  Customized titanium reconstruction of post-traumatic orbital wall defects: a review of 22 cases. , 2011, International journal of oral and maxillofacial surgery.

[3]  P. Manson,et al.  Studies on Enophthalmos: II. The Measurement of Orbital Injuries and Their Treatment by Quantitative Computed Tomography , 1986, Plastic and reconstructive surgery.

[4]  Harald Essig,et al.  Precision of posttraumatic primary orbital reconstruction using individually bent titanium mesh with and without navigation: a retrospective study , 2013, Head & Face Medicine.

[5]  Alexander Schramm,et al.  Computer-assisted reconstruction of orbital floor based on cone beam tomography. , 2007, The British journal of oral & maxillofacial surgery.

[6]  M. Metzger,et al.  Preformed titanium meshes: a new standard? , 2007, Skull base : official journal of North American Skull Base Society ... [et al.].

[7]  Beat Hammer,et al.  Computer‐Assisted Secondary Reconstruction of Unilateral Posttraumatic Orbital Deformity , 2002, Plastic and reconstructive surgery.

[8]  D. Wiley,et al.  Preformed vs Intraoperative Bending of Titanium Mesh for Orbital Reconstruction , 2013, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[9]  M. Rana,et al.  Development and demonstration of a novel computer planning solution for predefined correction of enophthalmos in anophthalmic patients using prebended 3D titanium-meshes--a technical note. , 2012, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[10]  P. Manson,et al.  Deep orbital reconstruction for correction of post-traumatic enophthalmos. , 1987, Clinics in plastic surgery.

[11]  S. Berrone,et al.  Dimensions and volumes of the orbit and orbital fat in posttraumatic enophthalmos. , 2000, Dento maxillo facial radiology.

[12]  M C Metzger,et al.  Individually preformed titanium mesh implants for a true-to-original repair of orbital fractures. , 2006, International journal of oral and maxillofacial surgery.

[13]  Ralf Schön,et al.  Anatomical 3-dimensional pre-bent titanium implant for orbital floor fractures. , 2006, Ophthalmology.