Integrated automation for optimal demand management in commercial buildings considering occupant comfort

Abstract Implementing demand response (DR) in commercial buildings can play a major role in reducing building’s peak load. This improves the efficiency of electricity grids and mitigates expensive peak demand/energy charges for buildings. Due to the lack of Energy Management Systems, small and medium-sized commercial buildings have not historically played much role as a DR resource. This paper presents an integrated control of major loads in commercial buildings, i.e., cooling, lighting and plug loads that can maintain occupant environmental preferences. Each zone’s space temperature set points are optimally adjusted to maintain thermal comfort. Lighting levels, with and without daylight availability, are tightly controlled to maintain desired illuminance levels. Unlike other studies, this research contributes to improvement in functionalities of EnergyPlus by incorporating a 1-min resolution data set at the individual plug load level. The research evaluates total building performance including interdependencies between lighting, plug load, HVAC and control systems interacting in a realistic manner, both among themselves and with building occupants. In this paper, a method to determine the DR potential of a building, i.e., the amount of electrical demand (kW) by load type that can be shifted or shed, is discussed.

[1]  G. P. Maheshwari,et al.  Enhancement of building operations: A successful approach towards national electrical demand management , 2013 .

[2]  Liu Yang,et al.  Thermal comfort and building energy consumption implications - A review , 2014 .

[3]  R. Andersen,et al.  Occupant performance and building energy consumption with different philosophies of determining acceptable thermal conditions , 2009 .

[4]  Simon H. A. Begemann,et al.  Daylight, artificial light and people in an office environment, overview of visual and biological responses , 1997 .

[5]  David L. DiLaura,et al.  The lighting handbook : reference and application , 2011 .

[6]  Tony Roskilly,et al.  This Work Is Licensed under a Creative Commons Attribution 4.0 International License Royapoor M, Roskilly T. Building Model Calibration Using Energy and Environmental Data. Energy and Buildings Building Model Calibration Using Energy and Environmental Data Keywords: Model Calibration Measured Energy , 2022 .

[7]  Khee Poh Lam,et al.  Development of whole-building energy performance models as benchmarks for retrofit projects , 2011, Proceedings of the 2011 Winter Simulation Conference (WSC).

[8]  Catalina Spataru,et al.  Assessing demand response with heat pumps for efficient grid operation in smart grids , 2015 .

[9]  Richard E. Brown,et al.  After-hours power status of office equipment in the USA , 2005 .

[10]  Teresa Wu,et al.  Short-term building energy model recommendation system: A meta-learning approach , 2016 .

[11]  Weimin Wang,et al.  Technical Support Document: 50% Energy Savings Design Technology Packages for Medium Office Buildings , 2009 .

[12]  Sylvie Melki,et al.  Building simulation tools and their role in improving existing building designs , 2009, 2009 International Conference on Advances in Computational Tools for Engineering Applications.

[13]  Richard E. Brown,et al.  Electricity used by office equipment and network equipment in the U.S.: Detailed report and appendices , 2001 .

[14]  Kelum A. A. Gamage,et al.  Demand side management in smart grid: A review and proposals for future direction , 2014 .

[15]  Enedir Ghisi,et al.  Analysis of daylight calculated using the EnergyPlus programme , 2010 .

[16]  A. Al-Mulla,et al.  Demand management through centralized control system using power line communication for existing buildings , 2014 .

[17]  Yang Zhao,et al.  Demand side flexibility: potentials and building performance implications , 2016 .

[18]  Mbc Myriam Aries,et al.  Individual control of electric lighting in a daylit space , 2008 .

[19]  Peter Rumsey,et al.  Plug Load Reduction: The Next Big Hurdle for Net Zero Energy Building Design , 2010 .

[20]  Thomas Weng,et al.  Managing plug-loads for demand response within buildings , 2011, BuildSys '11.

[21]  B. Mohanty,et al.  Energy efficiency of office equipment in commercial buildings: The case of Thailand , 1997 .

[23]  John S. Reynolds,et al.  Overall and zonal energy end use in an energy conscious office building , 1994 .

[24]  J. Roturier,et al.  Energy-efficient office technologies : the 1 watt/1 volt-ampere challenge , 1998 .

[25]  James A. Love Manual switching patterns in private offices , 1998 .

[26]  Bruce Nordman,et al.  Electricity used by office equipment and network equipment in the US , 2002 .

[27]  Christopher Wilkins Heat Gain From Office Equipment , 2000 .

[28]  Er-Wei Bai,et al.  Developing a whole building cooling energy forecasting model for on-line operation optimization using proactive system identification , 2016 .

[29]  Nor Mariah Adam,et al.  A study on energy efficiency improvement opportunities for plug loads in buildings in the equatorial region , 2014 .

[30]  Hans Christian Gils,et al.  Assessment of the theoretical demand response potential in Europe , 2014 .

[31]  Anca D. Galasiu,et al.  Impact of window blinds on daylight-linked dimming and automatic on/off lighting controls , 2004 .

[32]  Eric Shen,et al.  Energy and visual comfort analysis of lighting and daylight control strategies , 2014 .

[33]  Mustafa A. Biviji,et al.  Lessons learned from smart grid enabled pricing programs , 2011, 2011 IEEE Power and Energy Conference at Illinois.

[34]  Tham Kwok Wai,et al.  A literature survey on measuring energy usage for miscellaneous electric loads in offices and commercial buildings , 2014 .

[35]  Saifur Rahman,et al.  A peak-load reduction computing tool sensitive to commercial building environmental preferences , 2016 .

[36]  Peng Xu,et al.  Introduction to Commercial Building Control Strategies and Techniques for Demand Response , 2007 .

[37]  Jessica Granderson,et al.  Small- and Medium-Sized Commercial Building Monitoring and Controls Needs: A Scoping Study , 2012 .

[38]  Sila Kiliccote,et al.  Strategies for Demand Response in Commercial Buildings , 2006 .

[39]  I. Metzger,et al.  Plug-Load Control and Behavioral Change Research in GSA Office Buildings , 2012 .

[40]  Minoru Mizuno,et al.  Energy saving potential of office equipment power management , 2004 .

[41]  Dj Carter,et al.  User attitudes toward occupant controlled office lighting , 2002 .

[42]  L. Brackney,et al.  Selecting a Control Strategy for Plug and Process Loads , 2012 .

[43]  Glenn Platt,et al.  Optimal supervisory HVAC control: Experiences in Australia , 2011 .

[44]  Hongseok Kim,et al.  A framework for baseline load estimation in demand response: Data mining approach , 2014, 2014 IEEE International Conference on Smart Grid Communications (SmartGridComm).

[45]  Bruce Nordman,et al.  PC and monitor night status: Power management enabling and manual turn-off , 1998 .

[46]  Anca D. Galasiu,et al.  Occupant preferences and satisfaction with the luminous environment and control systems in daylit offices: a literature review , 2006 .

[47]  Francesco Causone,et al.  A review of indices for assessing visual comfort with a view to their use in optimization processes to support building integrated design , 2015 .

[48]  M. Piette,et al.  Automated Demand Response Technology Demonstration Project for Small and Medium Commercial Buildings , 2012 .

[49]  Shengwei Wang,et al.  A Novel Air-conditioning System for Proactive Power Demand Response to Smart Grid☆ , 2014 .

[50]  Gail Brager,et al.  Commercial Office Plug Load Energy Consumption Trends and the Role of Occupant Behavior , 2016 .

[51]  Chanvit Chantrasrisalai,et al.  Lighting Heat Gain Parameters: Experimental Results (RP-1282) , 2007 .

[52]  Peter Boyce,et al.  Occupant use of switching and dimming controls in offices , 2006 .

[53]  Marilyn A. Brown,et al.  Demand response: A carbon-neutral resource? , 2015 .

[54]  Daniel E. Fisher,et al.  EnergyPlus: creating a new-generation building energy simulation program , 2001 .

[55]  Jennifer A. Veitch,et al.  Preferred luminous conditions in open-plan offices: research and practice recommendations , 2000 .

[56]  S. Poll,et al.  Pilot Study of a Plug Load Management System: Preparing for Sustainability Base , 2012, 2012 IEEE Green Technologies Conference.

[57]  Thorbjörn Laike,et al.  Lighting control systems in individual offices at high latitude: measurements of electricity savings and users preferences , 2014 .

[58]  J. Hugghins,et al.  Vending Machine Energy Consumption and VendingMiser Evaluation , 2000 .

[59]  Åke Blomsterberg,et al.  Energy saving potential and strategies for electric lighting in future North European, low energy office buildings: A literature review , 2011 .

[60]  Sybil Derrible,et al.  The cost of over-cooling commercial buildings in the United States , 2015 .

[61]  K. A. Antonopoulos,et al.  Numerical simulation of cooling energy consumption in connection with thermostat operation mode and comfort requirements for the Athens buildings , 2011 .

[62]  David M. Auslander,et al.  An architecture for enabling distributed plug load control for commercial building demand response , 2013, 2013 IEEE PES Innovative Smart Grid Technologies Conference (ISGT).

[63]  Dj Carter,et al.  Long-term patterns of use of occupant controlled office lighting , 2003 .