A lumped model of lymphatic systems suitable for large scale simulations

Even though the importance of the lymphatic System in the active regulation of body fluid balance, in the immune system and in cancer dissemination is well known, large scale models of its behaviour are still lacking. Specifically, while several distributed and lumped models of single elements of the lymphatic system have been proposed, models that can be used as subsystems to describe behaviour of large lymphatic networks using general purpose simulators are not yet available. In this paper we propose a lumped model, based on data available in current literature, that is implemented using standard mixed mode circuit representation syntax. This allows to build large and complex lymphatic networks and simulate their transient and steady state behaviour. The model presented in this paper is limited to the element known as lymphangion that is one of the main components in lymph transport. Since we do not have yet data regarding larger networks, we will limit for the time being our discussion to a short chain of lymphangions.

[1]  R. Black,et al.  Modelling the lymphatic system: challenges and opportunities , 2012, Journal of The Royal Society Interface.

[2]  A. Moriondo,et al.  Spontaneous activity in peripheral diaphragmatic lymphatic loops. , 2013, American journal of physiology. Heart and circulatory physiology.

[3]  Alfio Quarteroni,et al.  The circulatory system: from case studies to mathematical modeling , 2006 .

[4]  Federico Bizzarri,et al.  Lyapunov exponents computation for hybrid neurons , 2013, Journal of Computational Neuroscience.

[5]  G. S. Gajani,et al.  Periodic Small Signal Analysis of a Wide Class of Type-II Phase Locked Loops Through an Exhaustive Variational Model , 2012, IEEE Transactions on Circuits and Systems Part 1: Regular Papers.

[6]  R. Drake,et al.  Active lymphatic pumping and sheep lung lymph flow. , 1991, Journal of applied physiology.

[7]  A. Venugopal,et al.  Nonlinear lymphangion pressure-volume relationship minimizes edema. , 2010, American journal of physiology. Heart and circulatory physiology.

[8]  Federico Bizzarri,et al.  Extension of the variational equation to analog/digital circuits: numerical and experimental validation , 2013, Int. J. Circuit Theory Appl..

[9]  Melody A Swartz,et al.  Interstitial fluid and lymph formation and transport: physiological regulation and roles in inflammation and cancer. , 2012, Physiological reviews.

[10]  D. Zawieja,et al.  Intrinsic pump-conduit behavior of lymphangions. , 2007, American journal of physiology. Regulatory, integrative and comparative physiology.

[11]  S. Allen,et al.  Equivalent circuit technique for lymph flow studies. , 1986, The American journal of physiology.

[12]  A. Moriondo,et al.  Lymphatic anatomy and biomechanics , 2011, The Journal of physiology.

[13]  D. Zawieja,et al.  Physiology of human lymphatic contractility: a historical perspective. , 2001, Lymphology.

[14]  Giambattista Gruosso,et al.  Determination of Floquet Exponents for Small-Signal Analysis of Nonlinear Periodic Circuits , 2009, IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems.

[15]  N P Reddy,et al.  A mathematical model of flow through the terminal lymphatics. , 1995, Medical engineering & physics.

[16]  Soumitro Banerjee,et al.  Simulation of Real World Circuits: Extending Conventional Analysis Methods to Circuits Described by Heterogeneous Languages , 2014, IEEE Circuits and Systems Magazine.

[17]  E. Stranden,et al.  Lymphatic and transcapillary forces in patients with edema following operation for lower limb atherosclerosis. , 1982, Lymphology.

[18]  J. Moore,et al.  Simulation of a chain of collapsible contracting lymphangions with progressive valve closure. , 2011, Journal of biomechanical engineering.