Dynamic behavior of a building structure tested with base and mid-story isolation systems

Abstract The discrepancies of dynamic behavior in base-isolated and mid-story isolated buildings are investigated experimentally in this study. In a mid-story isolated building, the isolation system is incorporated into the mid-story rather than the base of the building. The shaking table test results disclose that with the same design of the isolated superstructure and isolation system, a mid-story isolated building has smaller fundamental modal quantities than a base-isolated building. Besides, the seismic response at the superstructure is mainly attributed to the fundamental mode response, while the higher mode responses contribute significantly to the seismic responses at the substructure below the isolation system. Therefore, the modal response spectrum analysis appropriately considering the contribution of higher modes, rather than the equivalent lateral force procedure only considering the fundamental mode, is suggested for the preliminary design of mid-story isolated buildings prior to performing nonlinear responses history analyses.

[1]  Jinkoo Kim,et al.  Vertical distribution of equivalent static loads for base isolated building structures , 2001 .

[2]  James M. Kelly,et al.  Base Isolation: Linear Theory and Design , 1990 .

[3]  C. Ventura,et al.  MODAL ANALYSIS OF NON-CLASSICALLY DAMPED LINEAR SYSTEMS , 1986 .

[4]  Ting-Yu Hsu,et al.  A fractional derivative model to include effect of ambient temperature on HDR bearings , 2001 .

[5]  Masahito Kobayashi,et al.  EARTHQUAKE RESPONSE PREDICTION AND ASEISMIC PERFORMANCE OF MID-STORY ISOLATED SYSTEM , 2002 .

[6]  Wilfred D. Iwan,et al.  Estimating inelastic response spectra from elastic spectra , 1980 .

[7]  Akira Wada,et al.  SEISMIC RESPONSE OF MID-STORY ISOLATED BULIDINGS , 1999 .

[8]  J. Juang Applied system identification , 1994 .

[9]  J. C. Wang,et al.  Seismic response prediction of HDR bearings using fractional derivative Maxwell model , 1998 .

[10]  Lin Su,et al.  Probabilistic responses of base-isolated structures to El centro 1940 and Mexico city 1985 earthquakes , 1992 .

[11]  Haruyuki Kitamura,et al.  THE PREDICTION FOR SEISMIC RESPONSES OF THE TWO-MASS MODEL WITH THE MID-STORY ISOLATION SYSTEM , 2001 .

[12]  Gilberto Mosqueda,et al.  Aseismic roof isolation system: analytic and shake table studies , 1999 .

[13]  J. M. Chiou,et al.  An equivalent linear model of lead-rubber seismic isolation bearings , 1996 .

[14]  J. N. Yang,et al.  A response spectrum approach for seismic analysis of nonclassically damped structures , 1990 .

[15]  Wilfred D. Iwan,et al.  The effective period and damping of a class of hysteretic structures , 1979 .

[16]  G. B. Warburton,et al.  Errors in response calculations for non‐classically damped structures , 1977 .

[17]  John F. Bonacci Design Forces for Drift and Damage Control: A Second Look at the Substitute Structure Approach , 1994 .

[18]  Harumi Yoneda,et al.  FULL-SCALE TESTS AND ANALYTICAL MODELING OF HIGH-DAMPING RUBBER BEARINGS UNDER TWO HORIZONTAL DIRECTIONAL LOADING , 2009 .

[19]  Lin Shu,et al.  simplified analysis on calculation model of interlayer seismic isolation , 2002 .

[20]  Kuo-Chun Chang,et al.  Simplified analysis of mid‐story seismically isolated buildings , 2011 .

[21]  Anil K. Chopra,et al.  Dynamics of Structures: Theory and Applications to Earthquake Engineering , 1995 .