Experimental investigation on correlation of corona-induced vibration and audible noise from DC conductor
暂无分享,去创建一个
Xiang Cui | Xingming Bian | Tiebing Lu | Xuebao Li | Donglai Wang | X. Cui | Donglai Wang | T. Lu | X. Bian | Xuebao Li | Ren Peng | Renhua Peng
[1] Masoud Farzaneh,et al. Mechanical vibration of HV conductors induced by corona: roles of the space charge and ionic wind , 1988 .
[2] Experimental Investigations , 1955 .
[3] A.C. Baker,et al. Investigation of the corona performance of conductor bundles for 800-kV transmission , 1975, IEEE Transactions on Power Apparatus and Systems.
[4] Xiang Cui,et al. The correlation between audible noise and corona current in time domain caused by single positive corona source on the conductor , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.
[5] Rui Xiao-ming. Characteristics of corona-induced vibration generated by corona discharge , 2012 .
[6] X. Cui,et al. Detailed characteristics of intermittent current pulses due to positive corona , 2014 .
[7] Xiang Cui,et al. Comparison between the audible noises generated from single corona source under DC and AC corona discharge , 2015 .
[8] D. J. Bosack,et al. Spectral Characteristics of Acoustic Noise from Metallic Protrusions and Water Droplets in High Electric Fields , 1974 .
[9] Trinh N. Giao,et al. Modes of Corona Discharges in Air , 1968 .
[10] Jinliang He,et al. Specific characteristics of negative corona currents generated in short point-plane gap , 2013 .
[11] Xiang Cui,et al. Time-domain characteristics of the audible noise generated by single corona source under positive voltage , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.
[12] Electrostatic force measurements in positive unipolar wire-to-plane corona discharges in air , 2004, physics/0407052.
[13] F. Bastien. Acoustics and gas discharges: applications to loudspeakers , 1987 .
[14] T. Adachi,et al. Mechanism and Preventive Method of Self-Excited Vibration of Corona Wire in an Electrostatic Precipitator , 1996 .
[15] M. Hara,et al. Characteristics of the repulsive force acting on a corona wire in parallel-plate electrodes , 1987 .
[16] M. Farzaneh,et al. Vibration of High Voltage Conductors Induced by Corona from Water Drops or Hanging Metal Points , 1984, IEEE Transactions on Power Apparatus and Systems.
[17] M. Allaire,et al. Experimental Investigations of Corona-Induced Vibration on High Voltage Conductors with Different Types of Supports , 1981, IEEE Transactions on Power Apparatus and Systems.
[18] M Brahami,et al. Numerical Analysis of the Induced Corona Vibrations on High-Voltage Transmission Lines Affected by Rainfall , 2011, IEEE Transactions on Power Delivery.
[19] Chao Zhou,et al. Modeling and numerical analysis of corona-induced vibration on high-voltage transmission line with raindrops , 2015 .
[20] Liming Wang,et al. Influence of surface contamination of conductor on positive corona-generated audible noise spectrum characteristics of HVDC system , 2015, 2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP).
[21] M. Farzaneh. Effects of the intensity of precipitation and transverse wind on the corona-induced vibration of HV conductors , 1991 .
[22] L. Phan,et al. A laboratory study of corona-induced vibration of high-voltage smooth aluminium D.C. conductors in a mass-spring configuration , 1981 .
[23] P. Herzog,et al. Modelling of negative point-to-plane corona loudspeaker , 2001 .
[24] Chao Zhou,et al. Mechanism and characteristic of rain-induced vibration on high-voltage transmission line , 2012 .