Implementation of a Biopotential Amplifier with a Conventional and Current-Balancing Approach for Foetal ECG Monitoring

In a biopotential monitoring system, the sensors, the front end circuit, microprocessor, digital signal processor and transmitter are important blocks. The front end circuit is capable of amplifying and conditioning the biosignal. The power requirement of a biopotential monitoring system depends on the individual blocks present in the system. Direct reduction of the power is not possible in the conventional instrumentation amplifier. The conventional instrumentation amplifier is not suitable for portable applications because it consumes much power and has a low common mode rejection ratio (CMRR). To optimize the power consumption and simplify the system architecture, the front end system adopts two-stage amplifiers. A current-balancing instrumentation amplifier approach that amplifies a biosignal is proposed to improve the noise performance and CMRR and minimize the area, power consumption, and cost. In this CBIA design, passive component mismatch is minimized. To obtain an ECG signal, the output of an instrumentation amplifier signal is further processed by high pass, low pass and notch filters to eliminate muscular noise, motion artefacts and power line interference. The resultant signal is interfaced to a personal computer through a USB/SPI interface after the conversion of the analogue biosignal into digital signals.

[1]  Refet Firat Yazicioglu,et al.  A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems , 2007, IEEE Journal of Solid-State Circuits.

[2]  Reza Muhammad Abdullah A High CMRR Instrumentation Amplifier for Biopotential Signal Acquisition , 2012 .

[3]  Yehya H. Ghallab,et al.  A 0.4-V Miniature CMOS Current Mode Instrumentation Amplifier , 2018, IEEE Transactions on Circuits and Systems II: Express Briefs.

[4]  Yong Lian,et al.  An ECG-on-Chip for Wearable Cardiac Monitoring Devices , 2010, 2010 Fifth IEEE International Symposium on Electronic Design, Test & Applications.

[5]  Hoi-Jun Yoo,et al.  Bio-Medical CMOS ICs , 2011, Integrated Circuits and Systems.

[6]  Hyoungho Ko,et al.  Fully Integrated Biopotential Acquisition Analog Front-End IC , 2015, Sensors.

[7]  Wu-Shiung Feng,et al.  A high performance current-mode instrumentation amplifier for biomedical applications , 2010, 2010 2nd International Conference on Signal Processing Systems.

[8]  Refet Firat Yazicioglu,et al.  A 160 $\mu{\rm A}$ Biopotential Acquisition IC With Fully Integrated IA and Motion Artifact Suppression , 2012, IEEE Transactions on Biomedical Circuits and Systems.

[9]  M. Y. Ren,et al.  Design of CMOS Instrumentation Amplifier , 2012 .

[10]  Sujay Deb,et al.  Energy efficient biopotential acquisition unit for wearable health monitoring applications , 2017, 2017 18th International Symposium on Quality Electronic Design (ISQED).

[11]  Chua-Chin Wang,et al.  A high performance current-balancing instrumentation amplifier for ECG monitoring systems , 2009, 2009 International SoC Design Conference (ISOCC).

[12]  Seunghyun Im,et al.  A versatile biopotential acquisition analog front end IC with effective DC offset and ripple rejection , 2014, 2014 International Symposium on Integrated Circuits (ISIC).

[13]  SeongHwan Cho,et al.  CMRR enhancement technique for IA using three IAs for bio-medical sensor applications , 2010, 2010 IEEE Asia Pacific Conference on Circuits and Systems.