Kinetics of in vivo bone deposition by bone marrow stromal cells within a resorbable porous calcium phosphate scaffold: An X‐ray computed microtomography study

Resorbable ceramic scaffolds based on Silicon stabilized tricalcium phosphate (Si‐TCP) were seeded with bone marrow stromal cells (BMSC) and ectopically implanted for 2, 4, and 6 months in immunodeficient mice. Qualitative and quantitative evaluation of the scaffold material was performed by X‐ray synchrotron radiation computed microtomography (microCT) with a spatial resolution lower than 5 µm. Unique to these experiments was that microCT data were first collected on the scaffolds before implantation and then on the same scaffolds after they were seeded with BMSC, implanted in the mice and rescued after different times. Volume fraction, mean thickness and thickness distribution were evaluated for both new bone and scaffold phases as a function of the implantation time. New bone thickness increased from week 8 to week 16. Data for the implanted scaffolds were compared with those derived from the analysis of the same scaffolds prior to implantation and with data derived from 100% hydroxyapatite (HA) scaffold treated and analyzed in the same way. At variance with findings with the 100% HA scaffolds a significant variation in the density of the different Si‐TCP scaffold regions in the pre‐ and post‐implantation samples was observed. In particular a post‐implantation decrease in the density of the scaffolds, together with major changes in the scaffold phase composition, was noticeable in areas adjacent to newly formed bone. Histology confirmed a better integration between new bone and scaffold in the Si‐TCP composites in comparison to 100% HA composites where new bone and scaffold phases remained well distinct. Biotechnol. Bioeng. 2007; 98: 271–281. © 2007 Wiley Periodicals, Inc.

[1]  N. Otsu A threshold selection method from gray level histograms , 1979 .

[2]  P Rüegsegger,et al.  Micro-CT examinations of trabecular bone samples at different resolutions: 14, 7 and 2 micron level. , 1998, Technology and health care : official journal of the European Society for Engineering and Medicine.

[3]  Peter X. Ma,et al.  Scaffolds for tissue fabrication , 2004 .

[4]  P Cloetens,et al.  A synchrotron radiation microtomography system for the analysis of trabecular bone samples. , 1999, Medical physics.

[5]  F Peyrin,et al.  Kinetics of in vivo bone deposition by bone marrow stromal cells into porous calcium phosphate scaffolds: an X-ray computed microtomography study. , 2006, Tissue engineering.

[6]  S. Bruder,et al.  Mesenchymal stem cells: building blocks for molecular medicine in the 21st century. , 2001, Trends in molecular medicine.

[7]  G. Daculsi,et al.  A review of bioceramics and fibrin sealant. , 2004, European cells & materials.

[8]  R Cancedda,et al.  Repair of large bone defects with the use of autologous bone marrow stromal cells. , 2001, The New England journal of medicine.

[9]  S. Kadiyala,et al.  Culture expanded canine mesenchymal stem cells possess osteochondrogenic potential in vivo and in vitro. , 1997, Cell transplantation.

[10]  A I Caplan,et al.  Repair of bone defects with marrow cells and porous ceramic. Experiments in rats. , 1989, Acta orthopaedica Scandinavica.

[11]  W. Fodor Tissue engineering and cell based therapies, from the bench to the clinic: The potential to replace, repair and regenerate , 2003, Reproductive biology and endocrinology : RB&E.

[12]  H. Precheur Bone graft materials. , 2007, Dental clinics of North America.

[13]  Paolo Giannoni,et al.  Tissue engineering and cell therapy of cartilage and bone. , 2003, Matrix biology : journal of the International Society for Matrix Biology.

[14]  C. Perry,et al.  Bone repair techniques, bone graft, and bone graft substitutes. , 1999, Clinical orthopaedics and related research.

[15]  M. Sayer,et al.  Resorbable bioceramics based on stabilized calcium phosphates. Part II: evaluation of biological response. , 2001, Biomaterials.

[16]  M. Mastrogiacomo,et al.  Tissue engineering of bone: search for a better scaffold. , 2005, Orthodontics & craniofacial research.

[17]  F Peyrin,et al.  Synchrotron radiation microtomography of bone engineered from bone marrow stromal cells. , 2004, Tissue engineering.

[18]  H. Hatano,et al.  Extracorporeal irradiated autogenous osteochondral graft: a histological study. , 2005, The Journal of bone and joint surgery. British volume.

[19]  Antonios G Mikos,et al.  Methods: a comparative analysis of radiography, microcomputed tomography, and histology for bone tissue engineering. , 2005, Tissue engineering.

[20]  Jitendra Malik,et al.  Scale-Space and Edge Detection Using Anisotropic Diffusion , 1990, IEEE Trans. Pattern Anal. Mach. Intell..

[21]  G. Muschler,et al.  Bone graft materials. An overview of the basic science. , 2000, Clinical orthopaedics and related research.

[22]  A Boyde,et al.  Autologous bone marrow stromal cells loaded onto porous hydroxyapatite ceramic accelerate bone repair in critical-size defects of sheep long bones. , 2000, Journal of biomedical materials research.

[23]  Dietmar Werner Hutmacher,et al.  Application of micro CT and computation modeling in bone tissue engineering , 2005, Comput. Aided Des..

[24]  I. Martin,et al.  Fibroblast growth factor-2 supports ex vivo expansion and maintenance of osteogenic precursors from human bone marrow. , 1997, Endocrinology.

[25]  M. Mastrogiacomo,et al.  Reconstruction of extensive long bone defects in sheep using resorbable bioceramics based on silicon stabilized tricalcium phosphate. , 2006, Tissue engineering.

[26]  P. Rüegsegger,et al.  A new method for the model‐independent assessment of thickness in three‐dimensional images , 1997 .