A Chicken Tissue Phantom for Studying an Electrical Impedance Tomography (EIT) System Suitable for Clinical Imaging

The study of practical phantoms is essential for assessing the reconstruction algorithms and instrumentation used in Electrical Impedance Tomography (EIT). Responses of saline phantoms with insulator inhomogeneities differ from the real tissue phantoms in several aspects. Also, it is difficult to reconstruct the actual resistivity of the insulator inhomogeneity in a saline background because of their large resistivity difference. A practical biological phantom consisting of two different materials with low resistivity difference is more suitable for impedance imaging studies. In order to demonstrate this, a chicken tissue phantom was developed to study the resistivity imaging in EIT. A 16-electrode array was placed inside the phantom tank filled with chicken muscle tissue paste and chicken tissue. A 1 mA, 50 kHz sinusoidal current was injected at the phantom boundary and the boundary potentials are measured using opposite current injection protocol. Resistivity images were reconstructed from the boundary data using Electrical Impedance and Diffuse Optical Reconstruction Software (EIDORS) and the reconstruction was evaluated by calculating the contrast parameters of the images. Results show that the resistivity of the chicken fat is successfully reconstructed with a proper background resistivity. Impedance spectroscopic studies show that the chicken tissue phantom can be suitably used to evaluate a multifrequency EIT system.

[1]  Philippe Renaud,et al.  Cell Culture Imaging Using Microimpedance Tomography , 2008, IEEE Transactions on Biomedical Engineering.

[2]  Tushar Kanti Bera,et al.  Resistivity imaging of a reconfigurable phantom with circular inhomogeneities in 2D-electrical impedance tomography , 2011 .

[3]  Tushar Kanti Bera,et al.  A multifrequency constant current source suitable for Electrical Impedance Tomography (EIT) , 2010, 2010 International Conference on Systems in Medicine and Biology.

[4]  J. Reddy An introduction to the finite element method , 1989 .

[5]  José Hinz,et al.  Regional ventilation by electrical impedance tomography: a comparison with ventilation scintigraphy in pigs. , 2003, Chest.

[6]  D S Holder,et al.  An electrode addressing protocol for imaging brain function with electrical impedance tomography using a 16-channel semi-parallel system , 2009, Physiological measurement.

[7]  J. Ravenel The Essential Physics of Medical Imaging, 2nd ed. , 2003 .

[8]  Richard H. Bayford,et al.  Electrical impedance tomography of human brain function using reconstruction algorithms based on the finite element method , 2003, NeuroImage.

[9]  D S Holder,et al.  Some practical biological phantoms for calibrating multifrequency electrical impedance tomography. , 1996, Physiological measurement.

[10]  Dr D. Jennings,et al.  Design of an electrical impedance tomography phantom using active elements , 2000, Medical and Biological Engineering and Computing.

[11]  R M Heethaar,et al.  Improvement of cardiac imaging in electrical impedance tomography by means of a new electrode configuration. , 1996, Physiological measurement.

[12]  Tushar Kanti Bera,et al.  A FEM-Based Forward Solver for Studying the Forward Problem of Electrical Impedance Tomography (EIT) with A Practical Biological Phantom , 2009, 2009 IEEE International Advance Computing Conference.

[13]  Eung Je Woo,et al.  Finite element method and reconstruction algorithms in electrical impedance tomography , 2006, Annals of Biomedical Engineering.

[14]  Tushar Kanti Bera,et al.  A Simple instrumentation calibration technique for Electrical Impedance Tomography (EIT) using a 16-electrode phantom , 2009, 2009 IEEE International Conference on Automation Science and Engineering.

[15]  S. Arridge Optical tomography in medical imaging , 1999 .

[16]  William R B Lionheart,et al.  A Matlab toolkit for three-dimensional electrical impedance tomography: a contribution to the Electrical Impedance and Diffuse Optical Reconstruction Software project , 2002 .

[17]  L M Heikkinen,et al.  A MATLAB package for the EIDORS project to reconstruct two-dimensional EIT images. , 2001, Physiological measurement.

[18]  G Malandain,et al.  Model-based respiratory motion compensation for emission tomography image reconstruction , 2007, Physics in medicine and biology.

[19]  Levent Ovacik,et al.  Impedance imaging relative to gas-liquid systems , 1993 .

[20]  Tushar Kanti Bera,et al.  Studying the Boundary Data Profile of a Practical Phantom for Medical Electrical Impedance Tomography with Different Electrode Geometries , 2009 .

[21]  J Rosell,et al.  Common-mode feedback in electrical impedance tomography. , 1992, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[22]  J. Conway Electrical impedance tomography for thermal monitoring of hyperthermia treatment: an assessment using in vitro and in vivo measurements. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[23]  T. Hope,et al.  Technology review: The use of electrical impedance scanning in the detection of breast cancer , 2003, Breast Cancer Research.

[24]  David S. Holder,et al.  Electrical Impedance Tomography : Methods, History and Applications , 2004 .

[25]  L Tarassenko,et al.  Impedance imaging in the newborn. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[26]  B. M. Graham,et al.  Enhancements in Electrical Impedance Tomography (EIT) image reconstruction for three-dimensional lung imaging , 2007 .

[27]  C. J. Grootveld Measuring & modeling of concentrated settling suspensions using electrical impedance tomography , 1996 .

[28]  K. Rajan,et al.  Interior photon absorption based adaptive regularization improves diffuse optical tomography , 2010, International Conference on Digital Image Processing.

[29]  R M Vasu,et al.  Diffuse optical tomography using intensity measurements and the a priori acquired regions of interest: theory and simulations , 2005, Physics in medicine and biology.

[30]  David Barber,et al.  Three dimensional electrical impedance tomography of the human thorax , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[31]  M. Steinfath,et al.  Regional ventilation distribution determined by electrical impedance tomography: Reproducibility and effects of posture and chest plane , 2011, Respirology.

[32]  C. J. Kotre,et al.  Subsurface electrical impedance imaging: measurement strategy, image reconstruction and in vivo results. , 1996, Physiological measurement.

[33]  Hamid Dehghani,et al.  A novel data calibration scheme for electrical impedance tomography. , 2003, Physiological measurement.

[34]  Mi Wang,et al.  Electrical resistance tomography for process applications , 1996 .

[35]  Denyer Cwl Electronics for real-time and three-dimensional electrical impedance tomographs. , 1996 .

[36]  H Griffiths A phantom for electrical impedance tomography. , 1988, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[37]  Manuchehr Soleimani,et al.  A DSP Based Multi-Frequency 3D Electrical Impedance Tomography System , 2008, Annals of Biomedical Engineering.

[38]  E. Barsoukov,et al.  Impedance spectroscopy : theory, experiment, and applications , 2005 .

[39]  William R B Lionheart EIT reconstruction algorithms: pitfalls, challenges and recent developments. , 2004, Physiological measurement.

[40]  Thomas J. Yorkey,et al.  Comparing reconstruction methods for electrical impedance tomography , 1987, Annals of Biomedical Engineering.

[41]  Tushar Kanti Bera,et al.  A study of practical biological phantoms with simple instrumentation for Electrical Impedance Tomography (EIT) , 2009, 2009 IEEE Instrumentation and Measurement Technology Conference.

[42]  Phaneendra K. Yalavarthy,et al.  Helmholtz-Type Regularization Method for Permittivity Reconstruction Using Experimental Phantom Data of Electrical Capacitance Tomography , 2010, IEEE Transactions on Instrumentation and Measurement.

[43]  K. Cho,et al.  A fast EIT image reconstruction method for the two-phase flow visualization , 1999 .

[44]  T. Chan,et al.  Level set and total variation regularization for elliptic inverse problems with discontinuous coefficients , 2004 .

[45]  Manuchehr Soleimani,et al.  Nonlinear image reconstruction for electrical capacitance tomography using experimental data , 2005 .

[46]  R H Bayford,et al.  Bioimpedance tomography (electrical impedance tomography). , 2006, Annual review of biomedical engineering.

[47]  J. Boone,et al.  Comprar Essential Physics Of Medical Imaging, International Edition | Jerrold T. Bushberg | 9781451118100 | Lippincott Williams & Wilkins , 2012 .

[48]  Eung Je Woo,et al.  Frequency-difference electrical impedance tomography: phantom imaging experiments , 2010 .

[49]  Wei Wang,et al.  Investigation of biological phantom for 2D and 3D breast EIT images , 2007 .

[50]  W. Hou,et al.  New regularization method in electrical impedance tomography , 2002 .

[51]  David Isaacson,et al.  Electrical Impedance Tomography , 1999, SIAM Rev..

[52]  Hung-Yuan Chung,et al.  The Scanning Data Collection Strategy for Enhancing the Quality of Electrical Impedance Tomography , 2008, IEEE Transactions on Instrumentation and Measurement.