Amount-dependent isotopic fractionation during compound-specific isotope analysis.

The performance of a gas chromatography-combustion-isotope ratio mass spectrometry system (GC-C-IRMS) with respect to the dependence of delta(13)C values on the amount of sample is presented. Particular attention is paid to the localization of the amount-dependent isotopic fractionation within the system. Injection experiments with varying amounts of gases (CO(2), n-hexane, and toluene) revealed that neither the detector unit nor the combustion reactor, but rather the conditions in the split/splitless injector, contributed to this effect. Although optimization of injector parameters was performed and a reduction of this adverse effect from 3 to 1 per thousand was achieved, it was not possible to eliminate isotopic fractionation completely. Consequently, additional injector parameters have to be considered and adjusted to achieve injection conditions free of fractionation. For routine analysis of the compound-specific delta(13)C analysis of different biomarkers in many environmental samples, perfect optimization may not always be reached. Therefore, in order to prevent systematic errors in the measured delta(13)C values due to different sample concentrations, it is suggested that correction for the remaining unknown amount-dependent fractionation can be made by means of co-analyzing standards of varying analyte concentrations and known delta(13)C values. Residual overall amount-dependent isotope-fractionation can thus be corrected mathematically.

[1]  B. Glaser,et al.  Determination of 13C natural abundance of amino acid enantiomers in soil: methodological considerations and first results , 2002 .

[2]  W. Brand,et al.  Referencing strategies and techniques in stable isotope ratio analysis. , 2001, Rapid communications in mass spectrometry : RCM.

[3]  K. Grob Split and Splitless Injection for Quantitative Gas Chromatography: Concepts, Processes, Practical Guidelines, Sources of Error , 2001 .

[4]  E. Lichtfouse,et al.  Rapid Communications in Mass Spectrometry , 2022 .

[5]  Routine analysis by high precision gas chromatography/mass selective detector/isotope ratio mass spectrometry to 0.1 parts per mil. , 1999, Rapid communications in mass spectrometry : RCM.

[6]  Schweizer,et al.  Isotopic ((13)C) fractionation during plant residue decomposition and its implications for soil organic matter studies. , 1999, Rapid communications in mass spectrometry : RCM.

[7]  W. Meier-Augenstein,et al.  Applied gas chromatography coupled to isotope ratio mass spectrometry. , 1999, Journal of chromatography. A.

[8]  K. Ohlsson,et al.  Novel calibration with correction for drift and non-linear response for continuous flow isotope ratio mass spectrometry applied to the determination of δ15N, total nitrogen, δ13C and total carbon in biological material† , 1999 .

[9]  W. Meier-Augenstein A reference gas inlet module for internal isotopic calibration in high precision gas chromatography/combustion-isotope ratio mass spectrometry , 1997 .

[10]  Pietro Traldi,et al.  Rapid Commun. Mass Spectrom.10. 1629-1637 (1996) Matrix-assisted Laser Desorption/Ionisation Mass Spectrometry in Milk Science , 1997 .

[11]  H. Tobias,et al.  High-precision continuous-flow isotope ratio mass spectrometry. , 1997, Mass spectrometry reviews.

[12]  P. Watt,et al.  Influence of gas chromatographic parameters on measurement of 13C/12C isotope ratios by gas-liquid chromatography-combustion isotope ratio mass spectrometry. I , 1996 .

[13]  T. Eglinton,et al.  Stable carbon isotopic analyses of lignin-derived CuO oxidation products by isotope ratio monitoring-gas chromatography-mass spectrometry (irm-GC-MS) , 1996 .

[14]  J. Hayes,et al.  Performance and optimization of a combustion interface for isotope ratio monitoring gas chromatography/mass spectrometry. , 1995, Analytical chemistry.

[15]  J. Hayes,et al.  Factors controlling precision and accuracy in isotope-ratio-monitoring mass spectrometry. , 1994, Analytical chemistry.

[16]  J. Hayes,et al.  Acquisition and processing of data for isotope-ratio-monitoring mass spectrometry. , 1994, Organic geochemistry.

[17]  G. Rieley Derivatization of organic compounds prior to gas chromatographic–combustion–isotope ratio mass spectrometric analysis: identification of isotope fractionation processes , 1994 .