Electric field probes--A review

Electric field probes consisting of a dipole antenna, RF detector, nonperturbing transmission line, and readout device have been implemented in a variety of ways. Three orthogonal dipoles are generally used in an E -field probe to provide a response which is nearly isotropic for all polarizations of the incident field. Diode detectors have been used with electrically short or resistivity loaded dipoles to produce very broadband devices (0.2 MHz to 26 GHz). Thermocouple detectors are used to provide true time-averaged data for high peak-power modulated fields. Optical fibers, together with a suitably modulated light source, may be used to form a wide-band nonperturbing data link from the dipole and detector to a remote readout. Application of E -field probes range from the measurement of fields in living animals exposed to nonionizing radiation to the measurement of fields in air for electromagnetic compatability or radiation safety purposes. Probes are available that can measure field strengths from less than 1 V/m to over 1000 V/m (rms).

[1]  C. L. Andrews Erratum: Diffraction Pattern in a Circular Aperture Measured in the Microwave Region , 1950 .

[2]  A. Rudge An Electromagnetic Radiation Probe for Near-Field Measurements at Microwave Frequencies* , 1970 .

[3]  Edward E. Aslan,et al.  Electromagnetic Radiation Survey Meter , 1970 .

[4]  R. R. Bowman,et al.  Quantifying Hazardous Electromagnetic Fields: Scientific Basis and Practical Considerations , 1971 .

[5]  A. Guy,et al.  Nonionizing electromagnetic wave effects in biological materials and systems , 1972 .

[6]  Edward E. Aslan,et al.  Broad-Band Isotropic Electromagnetic Radiation Monitor , 1972 .

[7]  M. Swicord,et al.  A MINIATURE BROAD‐BAND ELECTRIC FIELD PROBE , 1975, Annals of the New York Academy of Sciences.

[8]  Glenn S. Smith A Comparison of Electrically Short Bare and Insulated Probes for Measuring the Local Radio Frequency Electric Field in Biological Systems , 1975, IEEE Transactions on Biomedical Engineering.

[9]  S. A. Oliva,et al.  A Multiple-Animal Array for Equal Power Density Microwave Irradiation (Short Papers) , 1977 .

[10]  H. Bassen,et al.  Evaluation of an implantable electric‐field probe within finite simulated tissues , 1977 .

[11]  Peter Weissglas,et al.  Local oscillators for frequency agile systems , 1977 .

[12]  Howard Bassen,et al.  An Optically Linked Telemetry System for Use with Electromagnetic-Field Measurement Probes , 1978, IEEE Transactions on Electromagnetic Compatibility.

[13]  G. Kantor,et al.  The Performance of a New Direct Contact Applicator for Microwave Diathermy , 1978 .

[14]  G. Smith The Electric-Field Probe Near a Material Interface with Application to the Probing of Fields in Biological Bodies , 1979 .

[15]  J. Lehmann,et al.  A comparison of patterns of stray radiation from therapeutic microwave applicators measured near tissue‐substitute models and human subjects , 1979 .

[16]  An Ultra Broad-Band (200 kHz-26 GHz) High-Sensitivity Probe , 1980, IEEE Transactions on Instrumentation and Measurement.

[17]  E B Larsen,et al.  Design and Calibration of the NBS Isotropic Electric-Field Monitor (EFM- 5), 0.2 to 1000 MHz , 1981 .

[18]  G. S. Smith Analysis of Miniature Electric Field Probes with Resistive Transmission Lines , 1981 .