Improved Splines Fitting of Intervertebral Motion by Local Smoothing Variation

Knowledge of intervertebral motion provides important information about the level of stabilization of a single spine segment. By using X-ray fluoroscopy it is possible to screen spinal motion during spontaneous patient’s movement. Discrete-time experimental measurements can be interpolated by smoothing splines, which provide both noise reduction and continuous-time representation of joint motion. A patient, albeit trained, is unable to perform a spontaneous movement with such regularity to keep constant certain parameters such as the speed. Therefore, spontaneous motion can include different tracts performed at different speed. The use of a single smoothing parameter to fit the entire motion for spline fitting requires a compromise. Alternatively, smaller differences with the experimental data and more stable motion parameters can be obtained by appropriately varying the smoothing parameter: less smoothing is applied in higher velocity tracts. This concept has been applied to the analysis of cervical intervertebral motion as obtained by processing sequences of fluoroscopic images. Preliminary results showed more close representation of the experimental data without missing the regular progression of the joint movement.

[1]  H. van Mameren,et al.  Cervical Spine Motion in the Sagittal Plane II: Position of Segmental Averaged Instantaneous Centers of Rotation -A Cineradiographic Study , 1992, Spine.

[2]  Maria Romano,et al.  2D-3D Registration of CT Vertebra Volume to Fluoroscopy Projection: A Calibration Model Assessment , 2010, EURASIP J. Adv. Signal Process..

[3]  Maria Romano,et al.  Analysis and Modelling of Muscles Motion during Whole Body Vibration , 2010, EURASIP J. Adv. Signal Process..

[4]  M M Panjabi,et al.  Cervical spine motion in the sagittal plane: kinematic and geometric parameters. , 1982, Journal of Biomechanics.

[5]  Jürgen Weese,et al.  A comparison of similarity measures for use in 2-D-3-D medical image registration , 1998, IEEE Transactions on Medical Imaging.

[6]  P. Bifulco,et al.  Automatic recognition of vertebral landmarks in fluoroscopic sequences for analysis of intervertebral kinematics , 2006, Medical and Biological Engineering and Computing.

[7]  Paolo Bifulco,et al.  A comparison of denoising methods for X-ray fluoroscopic images , 2012, Biomed. Signal Process. Control..

[8]  J H Challis,et al.  An examination of procedures for determining body segment attitude and position from noisy biomechanical data. , 1995, Medical engineering & physics.

[9]  John A. Hipp,et al.  Threshold Cervical Range-of-Motion Necessary to Detect Abnormal Intervertebral Motion in Cervical Spine Radiographs , 2008, Spine.

[10]  Thomas R Oxland,et al.  Degenerative mechanics of the lumbar spine. , 2004, The spine journal : official journal of the North American Spine Society.

[11]  A. White,et al.  Biomechanical analysis of clinical stability in the cervical spine. , 1975, Clinical orthopaedics and related research.

[12]  Jiri Dvorak,et al.  On the Understanding of Clinical Instability , 1994, Spine.

[13]  W. I. Steudel,et al.  Assessment of adjacent-segment mobility after cervical disc replacement versus fusion: RCT with 1 year’s results , 2011, European Spine Journal.

[14]  Wolfgang Frobin,et al.  Increased Sagittal Plane Segmental Motion in the Lower Cervical Spine in Women With Chronic Whiplash-Associated Disorders, Grades I–II: A Case-Control Study Using a New Measurement Protocol , 2003, Spine.

[15]  Minho Kim,et al.  Evaluation of similarity measures for use in the intensity-based rigid 2D-3D registration for patient positioning in radiotherapy. , 2009, Medical physics.

[16]  Paolo Bifulco,et al.  Estimation of out-of-plane vertebra rotations on radiographic projections using CT data: a simulation study. , 2002, Medical engineering & physics.

[17]  Jack T Dennerlein,et al.  Interpolation of segment Euler angles can provide a robust estimation of segment angular trajectories during asymmetric lifting tasks. , 2010, Journal of biomechanics.

[18]  Luigi Paura,et al.  X-ray fluoroscopy noise modeling for filter design , 2013, International Journal of Computer Assisted Radiology and Surgery.

[19]  Maria Romano,et al.  A continuous description of intervertebral motion by means of spline interpolation of kinematic data extracted by videofluoroscopy. , 2012, Journal of biomechanics.

[20]  P Bifulco,et al.  Advanced template matching method for estimation of intervertebral kinematics of lumbar spine. , 2011, Medical engineering & physics.

[21]  C. Reitman,et al.  Intervertebral Motion After Incremental Damage to the Posterior Structures of the Cervical Spine , 2005, Spine.