Derating the three-phase power distribution transformers under nonsinusoidal operating conditions: A case study

The paper quantitatively investigates the problem of derating the in-service distribution power transformers that supply heavy nonlinear balanced loads. The adopted computation method basis on the international standards and only requires the basic power quality parameters measured at the secondary winding of the transformer and its certified test report. Hence, by computing the major transformer harmonic factors, an on-site derating report is generated, which provides the additional power losses generated by the harmonic currents and the corresponding transformer maximum permissible current (reduction in apparent power rating). The paper also critically analyzes other solutions that could avoid or minimize the harmonics detrimental effects on the transformers steady-state operation. The study is carried out on a 1600 kVA oil-filled type distribution transformer that serves both linear and nonlinear industrial loads.

[1]  A. E. Emanuel,et al.  Corrected harmonic loss factor for transformers supplying nonsinusoidal load currents , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).

[2]  A. W. Galli,et al.  Temperature rise of small oil-filled distribution transformers supplying nonsinusoidal load currents , 1996 .

[3]  M. Masoum,et al.  Derating of Asymmetric Three-Phase Transformers Serving Unbalanced Nonlinear Loads , 2008, IEEE Transactions on Power Delivery.

[4]  Francisco C. De La Rosa Harmonics and Power Systems , 2006 .

[5]  P. J. Rose,et al.  Harmonics: the effects on power quality and transformers , 1994 .

[6]  E. F. Fuchs,et al.  Corrections to "measured transformer derating and comparison with harmonic loss factor (F/sub HL/) approach" , 2000 .

[7]  J. Faiz,et al.  Mixed Derating of Distribution Transformers Under Unbalanced Supply Voltage and Nonlinear Load Conditions Using TSFEM , 2010, IEEE Transactions on Power Delivery.

[8]  K. H. Sueker Comments on "Harmonics: the effects on power quality and transformers" , 1995 .

[9]  Ismail Daut,et al.  The effects of harmonic components on transformer losses of sinusoidal source supplying non-linear loads , 2006 .

[10]  M. S. Naderi,et al.  Effects of current and voltage harmonics on distribution transformer losses , 2012, 2012 IEEE International Conference on Condition Monitoring and Diagnosis.

[11]  L. W. Pierce Transformer design and application considerations for nonsinusoidal load currents , 1995 .

[12]  Christian COLLOMBET Harmonic disturbances in networks, and their treatment , 2000 .

[13]  C. Sankaran Power Quality , 2001 .

[14]  W. M. Grady,et al.  Measurement of eddy-current loss coefficient P/sub EC-R/, derating of single-phase transformers, and comparison with K-factor approach , 2000 .

[15]  R. D. Henderson,et al.  Harmonics: the effects on power quality and transformers , 1994, [Proceedings] IEEE 1993 Annual Textile, Fiber and Film Industry Technical Conference.

[16]  Mohammad A. S. Masoum,et al.  Power Quality in Power Systems and Electrical Machines , 2008 .

[17]  G. W. Massey Estimation methods for power system harmonic effects on power distribution transformers , 1993, [Proceedings] 1993 Rural Electric Power Conference. Papers Presented at the 37th Annual Conference.

[18]  M. A. S. Masoum,et al.  Load management in smart grids considering harmonic distortion and transformer derating , 2010, 2010 Innovative Smart Grid Technologies (ISGT).

[19]  Xiao Xiangning,et al.  Comparing transformer derating computed using the harmonic loss factor FHL and K-factor , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[20]  Syed Islam,et al.  The Effect of Nonsinusoidal Current Waveforms on Electromechanical and Solid-State Overcurrent Relay Operation , 2010 .

[21]  A. Singh,et al.  Aging of distribution transformers due to harmonics , 2010, Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010.

[22]  L.W. Pierce Transformer design and application considerations for nonsinusoidal load currents , 1995, 1995 IEEE Cement Industry Technical Conference. 37th Conference Record.

[23]  R. K. Tripathi,et al.  Power quality control of unregulated non-linear loads , 2010, 2010 International Conference on Power, Control and Embedded Systems.