Quantitative analysis with the optoacoustic/ultrasound system OPUS

The OPUS (Optoacoustic plus Ultrasound) system is a combination of a medical ultrasound scanner with a highrepetition rate, wavelength-tunable laser system and a suitable triggering interface to synchronize the laser and the ultrasound system. The pulsed laser generates an optoacoustic (OA), or photoacoustic (PA), signal which is detected by the ultrasound system. Alternatively, imaging in conventional ultrasound mode can be performed. Both imaging modes can be superimposed. The laser light is coupled into the tissue laterally, parallel to the ultrasound transducer, which does not require for any major modification to the transducer or the ultrasound beam forming. This was a basic requirement on the instrument, as the intention of the project was to establish the optoacoustic imaging modality as add-on to a conventional standard ultrasound instrument. We believe that this approach may foster the introduction of OA imaging as routine tool in medical diagnosis. Another key aspect of the project was to exploit the capabilities of OA imaging for quantitative analysis. The intention of the presented work is to summarize all steps necessary to extract the significant information from the PA raw data, which are required for the quantification of local absorber distributions. We show results of spatially resolved absorption measurements in scattering samples and a comparison of four different image reconstruction algorithms, regarding their influence on lateral resolution as well as on the signal to noise ratio for different sample depths and absorption values. The reconstruction algorithms are based on Fourier transformation, on a generalized 2D Hough transformation, on circular back-projection and the classical delay-and-sum approach which is implemented in most ultrasound scanners. Furthermore, we discuss the influence of a newly developed laser source, combining diode and flash lamp pumping. Compared to all-flash-lamp pumped systems it features a significantly higher pulse-to-pulse stability, which is required for sensitive and precise quantitative analyses.

[1]  Reinhard Niessner,et al.  Design and characterization of a highly directional photoacoustic sensor probe , 2006, SPIE BiOS.

[2]  Massoud Motamedi,et al.  Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study. , 2002, Applied optics.

[3]  A. Rosencwaig Photoacoustic Spectroscopy of Biological Materials , 1973, Science.

[4]  Hartmut Koenig,et al.  Photoacoustic image reconstruction: a quantitative analysis , 2007, European Conference on Biomedical Optics.

[5]  Liang Song,et al.  Realtime photoacoustic microscopy in vivo with a 30-MHz ultrasound array transducer. , 2008, Optics express.

[6]  Christoph Haisch,et al.  Quantitative analysis in medicine using photoacoustic tomography , 2009, Analytical and bioanalytical chemistry.

[7]  Lihong V. Wang,et al.  Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging , 2006, Nature Biotechnology.

[8]  G. Spanner,et al.  Noninvasive Determination of Blood Contents , 1996 .

[9]  G. B. Christison,et al.  Glucose determination by a pulsed photoacoustic technique: an experimental study using a gelatin-based tissue phantom. , 1993, Physics in medicine and biology.

[10]  J. Laufer,et al.  Absolute measurements of local chromophore concentrations using pulsed photoacoustic spectroscopy , 2006, SPIE BiOS.

[11]  Jan Laufer,et al.  In vitro measurements of absolute blood oxygen saturation using pulsed near-infrared photoacoustic spectroscopy: accuracy and resolution. , 2005, Physics in medicine and biology.

[12]  Paul C. Beard,et al.  Three-dimensional photoacoustic imaging of vascular anatomy in small animals using an optical detection system , 2007, SPIE BiOS.

[13]  Reinhard Niessner,et al.  OPUS: optoacoustic imaging combined with conventional ultrasound for breast cancer detection , 2007, European Conference on Biomedical Optics.

[14]  Wiendelt Steenbergen,et al.  Analysis of three-dimensional photoacoustic imaging of a vascular tree in vitro , 2003 .

[15]  Harald Ditlbacher,et al.  Integrated waveguide sensor for acoustic wave detection in photoacoustic tomography , 2008, SPIE BiOS.

[16]  Wiendelt Steenbergen,et al.  Imaging of small vessels using photoacoustics: An in vivo study , 2004, Lasers in surgery and medicine.

[17]  Yaochun Shen,et al.  Advances in photoacoustic noninvasive glucose testing. , 1999, Clinical chemistry.

[18]  G. Spanner,et al.  New concept for the non-invasive determination of physiological glucose concentrations using modulated laser diodes , 1996, Analytical and bioanalytical chemistry.

[19]  Martin Frenz,et al.  Combined ultrasound and optoacoustic system for real-time high-contrast vascular imaging in vivo , 2005, IEEE Transactions on Medical Imaging.

[20]  L V Wang,et al.  Realtime photoacoustic microscopy of murine cardiovascular dynamics. , 2008, Optics express.

[21]  Wiendelt Steenbergen,et al.  The Twente Photoacoustic Mammoscope: system overview and performance , 2005, Physics in medicine and biology.

[22]  Alexander A. Oraevsky,et al.  Optoacoustic imaging of blood for visualization and diagnostics of breast cancer , 2002, SPIE BiOS.

[23]  G. Spanner,et al.  Noninvasive determination of blood constituents using an array of modulated laser diodes and a photoacoustic sensor head , 1996, Analytical and bioanalytical chemistry.

[24]  R. Niessner,et al.  Acoustical properties of selected tissue phantom materials for ultrasound imaging , 2007, Physics in medicine and biology.